Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 21:32:22 on December 11, 2000
Entry number 53359
keyword=Start_Run_1811_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1811 at Mon Dec 11 21:32:11 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.12e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.310585
Right Arm Q2 momentum : 0.000721674
Right Arm Q2 gauss meter : 0.0006132
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97726
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.19251
Right Arm Q3 power supply current : -0.0209217
Right Arm Q3 momentum : -5.25792e-05
Right Arm Q3 gauss meter : 0.0002675
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.7
Left Arm Q2 momentum : 3.35973
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.38
Left Arm Q3 momentum : 3.35925
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.4966
Current on Unser monitor : 54.6207
Current on Upstream bcm : 58.6205
Current on Downstream bcm : 58.3727
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 107.721
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.4
haSC200_6_Sensor_2_R : 17.15
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.033
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.17
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.3
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 61.16
haITC502_5_Sensor_2_R : 59.56
haITC502_5_Sensor_3_R : 152.5
haITC502_6_Sensor_1_R : 94.89
haITC502_6_Sensor_2_R : 98.35
haITC502_6_Sensor_3_R : 26.59
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1359
HacR_VPM_LVDT:VALr : -1633
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.837891
HacR_alignROLL : -0.357857
HacR_alignPITCH : 0.0103274
HacR_alignHPT : -1.20538
HacL_HPM_LVDT:VALr : -8212
HacL_VPM_LVDT:VALr : 1326
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0824103
HacL_alignPITCH : -0.12795
HacL_alignHPT : 5.40539
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 282
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88