User name adev
Log entry time 18:54:41 on December 12, 2000
Entry number 53411
keyword=Start_Run_1831_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1831 at Tue Dec 12 18:54:31 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.52e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.109513
Right Arm Q2 momentum : 0.000254465
Right Arm Q2 gauss meter : 0.0005801
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97733
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.837376
Right Arm Q3 power supply current : 0.211403
Right Arm Q3 momentum : 0.000531284
Right Arm Q3 gauss meter : 0.0002754
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21417
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.34
Left Arm Q2 momentum : 3.35889
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.67
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.32
Left Arm Q3 momentum : 3.3591
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 57.853
Current on Unser monitor : 55.3979
Current on Upstream bcm : 57.6543
Current on Downstream bcm : 58.102
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 59.1622
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.43
haSC200_6_Sensor_2_R : 17.17
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 40.18
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.04
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 61.36
haITC502_5_Sensor_2_R : 59.74
haITC502_5_Sensor_3_R : 153.5
haITC502_6_Sensor_1_R : 95.25
haITC502_6_Sensor_2_R : 98.73
haITC502_6_Sensor_3_R : 26.55
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1344
HacR_VPM_LVDT:VALr : -1628
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.839355
HacR_alignROLL : -0.35835
HacR_alignPITCH : 0.0112253
HacR_alignHPT : -1.22189
HacL_HPM_LVDT:VALr : -8216
HacL_VPM_LVDT:VALr : 1322
HacL_HPE1313A:0_Ch58 : -0.130371
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.282715
HacL_alignROLL : 0.0819684
HacL_alignPITCH : -0.12795
HacL_alignHPT : 5.40784
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5093
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 309
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88