Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 09:55:47 on December 14, 2000
Entry number 53508
keyword=Start_Run_1869_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1869 at Thu Dec 14 09:55:36 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.2e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.311174
Right Arm Q2 momentum : 0.000723042
Right Arm Q2 gauss meter : 0.0005859
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97709
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.67237
Right Arm Q3 power supply current : 0.236913
Right Arm Q3 momentum : 0.000595396
Right Arm Q3 gauss meter : 0.0002193
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21418
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.65
Left Arm Q2 momentum : 3.35962
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.36
Left Arm Q3 momentum : 3.35919
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 66.2137
Current on Unser monitor : 60.8528
Current on Upstream bcm : 65.19
Current on Downstream bcm : 64.959
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 63.9056
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.21
haSC200_6_Sensor_2_R : 17.1
haSC200_6_Sensor_3_R : 3.01
haSC200_6_Sensor_4_R : 40.04
haHe_Omega_DPG_Sensor_R : -0.025
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.94
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.8
haITC502_5_Sensor_1_R : 62.21
haITC502_5_Sensor_2_R : 60.42
haITC502_5_Sensor_3_R : 157.3
haITC502_6_Sensor_1_R : 96.03
haITC502_6_Sensor_2_R : 99.53
haITC502_6_Sensor_3_R : 26.48
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1358
HacR_VPM_LVDT:VALr : -1621
HacR_HPE1313A:0_Ch58 : -0.570801
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.843262
HacR_alignROLL : -0.361596
HacR_alignPITCH : 0.0124518
HacR_alignHPT : -1.20548
HacL_HPM_LVDT:VALr : -8119
HacL_VPM_LVDT:VALr : 1387
HacL_HPE1313A:0_Ch58 : -0.128906
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.0827816
HacL_alignPITCH : -0.129622
HacL_alignHPT : 5.29795
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 339
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88