Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 10:48:32 on December 14, 2000
Entry number 53512
keyword=Start_Run_1870_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1870 at Thu Dec 14 10:48:21 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.47e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.323255
Right Arm Q2 momentum : 0.000751113
Right Arm Q2 gauss meter : 0.0005907
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97699
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.765688
Right Arm Q3 power supply current : 0.218911
Right Arm Q3 momentum : 0.000550153
Right Arm Q3 gauss meter : 0.00023
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.21415
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.54
Left Arm Q2 momentum : 3.35936
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.54
Left Arm Q3 momentum : 3.35966
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.6469
Current on Unser monitor : 54.7876
Current on Upstream bcm : 58.2013
Current on Downstream bcm : 59.0925
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 113.094
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.13
haSC200_6_Sensor_3_R : 2.97
haSC200_6_Sensor_4_R : 40.06
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.27
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 62.18
haITC502_5_Sensor_2_R : 60.51
haITC502_5_Sensor_3_R : 157.9
haITC502_6_Sensor_1_R : 96.03
haITC502_6_Sensor_2_R : 99.47
haITC502_6_Sensor_3_R : 26.48
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1363
HacR_VPM_LVDT:VALr : -1623
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.842285
HacR_alignROLL : -0.362031
HacR_alignPITCH : 0.0119371
HacR_alignHPT : -1.19852
HacL_HPM_LVDT:VALr : -8117
HacL_VPM_LVDT:VALr : 1386
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0822693
HacL_alignPITCH : -0.129547
HacL_alignHPT : 5.29819
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 309
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88