Log entry time 14:44:45 on December 14, 2000
Entry number 53520
keyword=Start_Run_1874_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
Beginning-of-run EPICS data for Run Number 1874 at Thu Dec 14 14:44:35 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.52e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.322155
Right Arm Q2 momentum : 0.000748559
Right Arm Q2 gauss meter : 0.0005792
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97678
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.19199
Right Arm Q3 power supply current : 0.23829
Right Arm Q3 momentum : 0.000598856
Right Arm Q3 gauss meter : 0.0002182
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21419
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.54
Left Arm Q2 momentum : 3.35935
Left Arm Q2 gauss meter : -0.7614
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.16
Left Arm Q3 momentum : 3.35869
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0326066
Current on Unser monitor : -4.32257
Current on Upstream bcm : 0.02994
Current on Downstream bcm : 0.0351756
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.26
haSC200_6_Sensor_2_R : 17.18
haSC200_6_Sensor_3_R : 2.96
haSC200_6_Sensor_4_R : 40.06
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.14
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.6
haITC502_4_Sensor_2_R : 18.9
haITC502_4_Sensor_3_R : 67
haITC502_5_Sensor_1_R : 62.15
haITC502_5_Sensor_2_R : 60.46
haITC502_5_Sensor_3_R : 158.6
haITC502_6_Sensor_1_R : 96.11
haITC502_6_Sensor_2_R : 99.6
haITC502_6_Sensor_3_R : 26.47
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1366
HacR_VPM_LVDT:VALr : -1621
HacR_HPE1313A:0_Ch58 : -0.570312
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.84375
HacR_alignROLL : -0.363018
HacR_alignPITCH : 0.0119371
HacR_alignHPT : -1.19572
HacL_HPM_LVDT:VALr : -8117
HacL_VPM_LVDT:VALr : 1391
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.281738
HacL_alignROLL : 0.0826408
HacL_alignPITCH : -0.129473
HacL_alignHPT : 5.29801
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7678
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88