    User name adev

    Log entry time 17:23:44 on December 16, 2000

    Entry number 53679

    keyword=End_of_Run_1938
    ****************************
     Run Number: 1938
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
    Fpp ch-4 tripped in th emiddle.
    
    
    Time of run = 35.837907 min
    Av. current (on 3x) = 50.368548 uA
    Av. current (on 1x) = 50.259911 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  108.0726  |  108.3062  |  106.8594
    up-down    (mC)|    1.4967  |    1.2526  |    2.0412
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6382006.1 /mC  |    1.786 Hz  | 691210830  | 180000   |   6395800.9 /mC
        2      |    108405.8 /mC  |    1.092 Hz  |  11741015  |  5000   |    108640.1 /mC
        3      |      6362.1 /mC  |  320.449 Hz  |    689053  |     1   |      6375.8 /mC
        4      |    745999.6 /mC  |   18.787 Hz  |  80796383  |  2000   |    747612.1 /mC
        5      |       589.4 /mC  |    0.000 Hz  |     63833  | 65535   |       590.6 /mC
        output                       328.596 Hz
    Av. deadtime from accepted triggers = 0.0395
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  321802.21  Hz     |    321047.79 Hz   |  321452.38 Hz
        2      |  5467.8164  Hz     |    5461.1491 Hz   |  5460.2403 Hz
        3      |  319.94091  Hz     |    320.76094 Hz   |  320.44887 Hz
        4      |  37617.918  Hz     |    37529.278 Hz   |  37574.917 Hz
        5      |  29.800318  Hz     |    29.676605 Hz   |  29.685979 Hz
        output |  0.0  Hz   |    0.0 Hz |   328.596 Hz
    Accepted triggers  = 706571.00000
     Time of run = 35.837907 min
     Time of run h- = 17.71766 min
     Time of run h+ = 17.716813 min
     1-(sum of time hel + and -)/( run time) = 1.1257e-02
    Rate of Left Arm Pulser for electronic DT  = 10.1694
    Rate of Right Arm Pulser for electronic DT  = 5.0560989
    Rate of Left Arm Pulser&trig for electronic DT  = 10.115453
    Rate of Right Arm Pulser&trig for electronic DT  = 5.0560989
    Left Arm Electronic DT  = 0.0053047972
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 62752.541
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.259493  Hz         |    0.0 Hz        |  11.259958 Hz
          -        |  0.0  Hz        |    11.259958 Hz       |  11.259958 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0538563         |   0.0537338         | 0.1088210     
       upstream 3x |   0.0539107         |   0.0537909         | 0.1089325     
       upstream 10x|   0.0533823         |   0.0532776         | 0.1078800     
      downstream   |   0.0531158         |   0.0529944         | 0.1073243    
     downstream 3x |   0.0532901         |   0.0531740         | 0.1076799    
     downstream 10x|   0.0523717         |   0.0522709         | 0.1058388    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -1.13858060e-03 
       upstream 3x |   -1.11233260e-03 
       upstream 10x|   -9.81624770e-04 
      downstream   |   -1.14409360e-03 
     downstream 3x |   -1.09050840e-03 
     downstream 10x|   -9.63278820e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1938 at Sat Dec 16 17:23:33 EST 2000
    Right Arm D1 momentum                    : 1
    Right Arm arm angle                      : 12.509
    Left Arm D1 momentum                      : 3.3593
    Left Arm arm angle                        : 23.7679
    Tiefenbach Hall A energy                : 4582.71
    Right Arm arm mispointing (HPT)          : -1.17522
    Left Arm arm mispointing (HPT)            : 5.28886
    Right Arm Q1 power supply current        : 751.94
    Right Arm Q1 momentum                    : 1.00001
    Right Arm Q1 gauss meter                 : -0.018778
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.294
    Right Arm Q2 momentum                    : 0.99983
    Right Arm Q2 gauss meter                 : 0.22552
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 343.002
    Right Arm D1 momentum                    : 1
    Right Arm D1 NMR                         : 0.371089
    Right Arm Q3 power supply current        : 398.031
    Right Arm Q3 momentum                    : 1.00031
    Right Arm Q3 gauss meter                 : 0.17787
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.59
    Left Arm Q1 momentum                      : 3.35968
    Left Arm Q1 gauss meter                   : 0.21417
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.66
    Left Arm Q2 momentum                      : 3.35964
    Left Arm Q2 gauss meter                   : -0.7615
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.67
    Left Arm D1 momentum                      : 3.3593
    Left Arm D1 NMR                           : 1.24416
    Left Arm Q3 power supply current          : 1337.61
    Left Arm Q3 momentum                      : 3.35983
    Left Arm Q3 gauss meter                   : 0.6672
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 59.5164
    Current on Unser monitor                : 55.9352
    Current on Upstream bcm                 : 59.6918
    Current on Downstream bcm               : 59.341
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 59.6278
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.71
    Tiefenbach Hall C energy                : 2323.98
    Delta(E)/E width (MV_AI_DXWID)          : 2.26598
    IPM1C12.XPOS                            : 0.0073722
    IPM1H04A.XPOS                           : 0.539768
    IPM1H04A.YPOS                           : 0.745256
    IPM1H04B.XPOS                           : 0.114191
    IPM1H04B.YPOS                           : -0.0487118
    Right Arm Arm Collimator                 : 0.363965
    Left Arm Arm Collimator                   : 0.868457
     HacR_HPM_LVDT:VALr                     : -1382
     HacR_VPM_LVDT:VALr                     : -1659
     HacR_HPE1313A:0_Ch58                   : -0.570312
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.84375
     HacR_alignROLL                         : -0.363075
     HacR_alignPITCH                        : 0.0106561
     HacR_alignHPT                          : -1.17554
     HacL_HPM_LVDT:VALr                     : -8111
     HacL_VPM_LVDT:VALr                     : 1380
     HacL_HPE1313A:0_Ch58                   : -0.12793
     HacL_HPE1313A:0_Ch55                   : 23.7305
     HacL_HPE1313A:0_Ch54                   : -0.28125
     HacL_alignROLL                         : 0.0826408
     HacL_alignPITCH                        : -0.129473
     HacL_alignHPT                          : 5.29243
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.47
    haH2_P_Exhaust_R                         : 22.65
    haH2_P_Fill_Bottle_R                     : 22.93
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.718
    haSC200_6_Sensor_1_R                     : 242.23
    haSC200_6_Sensor_2_R                     : 17.05
    haSC200_6_Sensor_3_R                     : 3.02
    haSC200_6_Sensor_4_R                     : 40.06
    haHe_Omega_DPG_Sensor_R                  : -0.033
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 89.11
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.18
    haITC502_4_Sensor_1_R                    : 76.2
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 66.6
    haITC502_5_Sensor_1_R                    : 62.66
    haITC502_5_Sensor_2_R                    : 60.82
    haITC502_5_Sensor_3_R                    : 154.3
    haITC502_6_Sensor_1_R                    : 96.72
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 26.34
    Right Arm Arm Collimator                 : 0.363916
    Left Arm Arm Collimator                   : 0.868408
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 381
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : OFF