    Log entry time 02:14:27 on December 17, 2000

    Entry number 53703

    keyword=End_of_Run_1948
    ****************************
     Run Number: 1948
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.0,Ene=4.58,Angle_R=12.509,Angle_L=23.768
    
    Time of run = 81.335823 min
    Av. current (on 3x) = 30.313888 uA
    Av. current (on 1x) = 30.244074 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  147.5956  |  147.9363  |  146.6764
    up-down    (mC)|    2.1531  |    1.6704  |    2.7610
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6420039.6 /mC  |    1.081 Hz  | 949756910  | 180000   |   6434859.2 /mC
        2      |    103012.0 /mC  |    0.625 Hz  |  15239219  |  5000   |    103249.8 /mC
        3      |      6570.6 /mC  |  199.181 Hz  |    972031  |     1   |      6585.8 /mC
        4      |    753386.5 /mC  |   11.419 Hz  | 111453210  |  2000   |    755125.6 /mC
        5      |       700.5 /mC  |    0.000 Hz  |    103625  | 65535   |       702.1 /mC
        output                       205.009 Hz
    Av. deadtime from accepted triggers = 0.0344
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  194799.18  Hz     |    194444.56 Hz   |  194616.36 Hz
        2      |  3128.3225  Hz     |    3122.2421 Hz   |  3122.6952 Hz
        3      |  199.28629  Hz     |    199.02874 Hz   |  199.18058 Hz
        4      |  22862.265  Hz     |    22816.931 Hz   |  22838.073 Hz
        5      |  21.309957  Hz     |    21.199225 Hz   |  21.233981 Hz
        output |  0.0  Hz   |    0.0 Hz |   205.009 Hz
    Accepted triggers  = 1000474.00000
     Time of run = 81.335823 min
     Time of run h- = 40.209017 min
     Time of run h+ = 40.208903 min
     1-(sum of time hel + and -)/( run time) = 1.1285e-02
    Rate of Left Arm Pulser for electronic DT  = 10.168746
    Rate of Right Arm Pulser for electronic DT  = 5.0238216
    Rate of Left Arm Pulser&trig for electronic DT  = 10.136165
    Rate of Right Arm Pulser&trig for electronic DT  = 5.0236167
    Left Arm Electronic DT  = 0.0032040302
    Right Arm Electronic DT  = 4.0788025e-05
    Rate of Left Strobe  = 38615.444
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.264614  Hz         |    0.0 Hz        |  11.264819 Hz
          -        |  0.0  Hz        |    11.264614 Hz       |  11.264614 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0735678         |   0.0734269         | 0.1486721     
       upstream 3x |   0.0736145         |   0.0734774         | 0.1487715     
       upstream 10x|   0.0732548         |   0.0731308         | 0.1480569     
      downstream   |   0.0725025         |   0.0723635         | 0.1465190    
     downstream 3x |   0.0727866         |   0.0726538         | 0.1471011    
     downstream 10x|   0.0718875         |   0.0717683         | 0.1452959    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -9.58537960e-04 
       upstream 3x |   -9.32070360e-04 
       upstream 10x|   -8.47077850e-04 
      downstream   |   -9.59507410e-04 
     downstream 3x |   -9.13088800e-04 
     downstream 10x|   -8.29761140e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1948 at Sun Dec 17 02:14:10 EST 2000
    Right Arm D1 momentum                    : 0.999997
    Right Arm arm angle                      : 12.509
    Left Arm D1 momentum                      : 3.3593
    Left Arm arm angle                        : 23.7679
    Tiefenbach Hall A energy                : 4582.73
    Right Arm arm mispointing (HPT)          : -1.18453
    Left Arm arm mispointing (HPT)            : 5.2889
    Right Arm Q1 power supply current        : 751.87
    Right Arm Q1 momentum                    : 0.999914
    Right Arm Q1 gauss meter                 : -0.018768
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.561
    Right Arm Q2 momentum                    : 1.00045
    Right Arm Q2 gauss meter                 : 0.22555
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 342.993
    Right Arm D1 momentum                    : 0.999997
    Right Arm D1 NMR                         : 0.371087
    Right Arm Q3 power supply current        : 397.899
    Right Arm Q3 momentum                    : 0.999975
    Right Arm Q3 gauss meter                 : 0.1778
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.52
    Left Arm Q1 momentum                      : 3.35959
    Left Arm Q1 gauss meter                   : 0.2142
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.61
    Left Arm Q2 momentum                      : 3.35951
    Left Arm Q2 gauss meter                   : -0.7614
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.66
    Left Arm D1 momentum                      : 3.3593
    Left Arm D1 NMR                           : 1.24416
    Left Arm Q3 power supply current          : 1337.22
    Left Arm Q3 momentum                      : 3.35885
    Left Arm Q3 gauss meter                   : 0.6671
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 58.5282
    Current on Unser monitor                : 55.4257
    Current on Upstream bcm                 : 58.2997
    Current on Downstream bcm               : 58.7568
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 58.1218
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.73
    Tiefenbach Hall C energy                : 2323.99
    Delta(E)/E width (MV_AI_DXWID)          : 
    IPM1C12.XPOS                            : -0.0112476
    IPM1H04A.XPOS                           : 0.397474
    IPM1H04A.YPOS                           : 0.832335
    IPM1H04B.XPOS                           : -0.0318914
    IPM1H04B.YPOS                           : 0.0476425
    Right Arm Arm Collimator                 : 0.363965
    Left Arm Arm Collimator                   : 0.868457
     HacR_HPM_LVDT:VALr                     : -1375
     HacR_VPM_LVDT:VALr                     : -1659
     HacR_HPE1313A:0_Ch58                   : -0.570801
     HacR_HPE1313A:0_Ch55                   : 22.8027
     HacR_HPE1313A:0_Ch54                   : -0.843262
     HacR_alignROLL                         : -0.362582
     HacR_alignPITCH                        : 0.0120029
     HacR_alignHPT                          : -1.18253
     HacL_HPM_LVDT:VALr                     : -8109
     HacL_VPM_LVDT:VALr                     : 1380
     HacL_HPE1313A:0_Ch58                   : -0.129395
     HacL_HPE1313A:0_Ch55                   : 23.7305
     HacL_HPE1313A:0_Ch54                   : -0.282227
     HacL_alignROLL                         : 0.0825703
     HacL_alignPITCH                        : -0.129399
     HacL_alignHPT                          : 5.29023
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.99
    haH2_P_Exhaust_R                         : 23.13
    haH2_P_Fill_Bottle_R                     : 23.43
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.745
    haSC200_6_Sensor_1_R                     : 242.4
    haSC200_6_Sensor_2_R                     : 17.13
    haSC200_6_Sensor_3_R                     : 3.07
    haSC200_6_Sensor_4_R                     : 40.18
    haHe_Omega_DPG_Sensor_R                  : -0.03
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 90.21
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19.01
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.19
    haITC502_4_Sensor_1_R                    : 76.5
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 66.9
    haITC502_5_Sensor_1_R                    : 62.52
    haITC502_5_Sensor_2_R                    : 60.75
    haITC502_5_Sensor_3_R                    : 155.4
    haITC502_6_Sensor_1_R                    : 96.61
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 26.31
    Right Arm Arm Collimator                 : 0.363916
    Left Arm Arm Collimator                   : 0.868506
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 402
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : OFF