keyword=Re.: ioc hallasc16 crash
Among other things, a log of the spectrometer
momentum changes
is kept by the IOCs. The log for hallasc16
(the Right spectrometer magnet control) between
5:00 and 8:00 AM Jan 11, 2001 is shown below.
From it, the only thing that one can conclude is that hallasc16
was working correctly. It will be nice if next time we could
get a more detail entry of the observed behaviour.
----------------------------------------
Jan 11, 2001 05:02:14.880501040
Imeas (A) = 400.826019, REGenable = 1
Bwrk (T) = 0.425638, Iset (A) = 390.493439, HALLreg = 0
NMRprobe = 1, NMRdac = 11202, Vcoil = 3.075234
Jan 11, 2001 06:04:34.628263578
Imeas (A) = 392.706543, REGenable = 1
Bwrk (T) = 0.416732, Iset (A) = 382.322723, HALLreg = 0
NMRprobe = 1, NMRdac = 11132, Vcoil = 3.010887
Jan 11, 2001 06:20:42.877475780
Imeas (A) = 392.705994, REGenable = 1
Bwrk (T) = 0.416730, Iset (A) = 382.321075, HALLreg = 0
NMRprobe = 1, NMRdac = 11132, Vcoil = 3.010874
Jan 11, 2001 06:34:27.011259421
Imeas (A) = 392.706268, REGenable = 0
Bwrk (T) = 0.416732, Iset (A) = 382.322723, HALLreg = 0
NMRprobe = 1, NMRdac = 11132, Vcoil = 3.010887
Jan 11, 2001 08:05:28.408410275
Imeas (A) = 384.297699, REGenable = 1
Bwrk (T) = 0.404486, Iset (A) = 371.087952, HALLreg = 0
NMRprobe = 1, NMRdac = 11033, Vcoil = 2.922410