Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 14:57:11 on January 11, 2001
Entry number 54341
keyword=Start_Run_1202_Tar=9foil-12C,Type=Optics,Lmom=0.838,Rmom=0.838,Ene=1.173,Angle_R=41.435,Angle_L=41.410
Beginning-of-run EPICS data for Run Number 1202 at Thu Jan 11 14:56:49 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=120,ps3=1,ps4=120,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 630.175
Right Arm Q1 momentum : 0.838071
Right Arm Q1 gauss meter : -0.015779
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 360.794
Right Arm Q2 momentum : 0.83834
Right Arm Q2 gauss meter : 0.18974
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 286.031
Right Arm D1 momentum : 0.838
Right Arm D1 NMR : 0.310972
Right Arm Q3 power supply current : 333.556
Right Arm Q3 momentum : 0.838272
Right Arm Q3 gauss meter : 0.14945
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 630.455
Left Arm Q1 momentum : 0.838002
Left Arm Q1 gauss meter : -0.05336
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 360.704
Left Arm Q2 momentum : 0.837678
Left Arm Q2 gauss meter : 0.19079
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 279.776
Left Arm D1 momentum : 0.837993
Left Arm D1 NMR : 0.310291
Left Arm Q3 power supply current : 333.601
Left Arm Q3 momentum : 0.837943
Left Arm Q3 gauss meter : -0.16624
Left Arm Q3 power supply polarity :
Average current of the two cavities : 14.953
Current on Unser monitor : 25.6199
Current on Upstream bcm : 15.1914
Current on Downstream bcm : 14.7147
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 77
Current on IBC0L02 (source) : 61.5183
Beam energy : 1174.57
MBSY1c magnet current (amp) : 48.6672
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.161172
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 35
haL3_Fan_frequency_R : 32
haSC200_6_Sensor_1_R : 242.43
haSC200_6_Sensor_2_R : 16.12
haSC200_6_Sensor_3_R : 3.11
haSC200_6_Sensor_4_R : 39.8
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 91.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 93.82
haITC502_5_Sensor_3_R : 271.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.05
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4786
HacR_VPM_LVDT:VALr : 508
HacR_HPE1313A:0_Ch58 : -0.539062
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.949219
HacR_alignROLL : -0.469838
HacR_alignPITCH : -0.0168441
HacR_alignHPT : 2.59088
HacL_HPM_LVDT:VALr : -8014
HacL_VPM_LVDT:VALr : -275
HacL_HPE1313A:0_Ch58 : -0.222168
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.23584
HacL_alignROLL : 0.124254
HacL_alignPITCH : -0.0461445
HacL_alignHPT : 5.16183
Right Arm Angle Floor Angle : 41.5
Right Arm Angle Vernier : -42.5
Right Arm Scattering Angle : 41.4345
Left Arm Angle Floor Angle : 41.5
Left Arm Angle Vernier : 21.5
Left Arm Scattering Angle : 41.41
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 133
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88