    User name adev

    Log entry time 10:26:37 on January 13, 2001

    Entry number 54581

    keyword=End_of_Run_1299
    ****************************
     Run Number: 1299
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=,mode=singles,Lmom=0.706,Rmom=0.706,Ene=1.173,Angle_R=56.64,Angle_L=56.67
    6% radiator in
    
    
    Time of run = 9.0327473 min
    Av. current (on 3x) = 20.770167 uA
    Av. current (on 1x) = 20.732526 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   11.2363  |   11.2567  |   11.2809
    up-down    (mC)|    0.2749  |    0.1990  |    0.2728
     Trigger | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1    | 2775.752 Hz  |    133641.3 /mC  |  925.251 Hz  |   1504360  |     3   |    133883.9 /mC
        2    | 34809.729 Hz  |   1675948.5 /mC  |    9.946 Hz  |  18865649  |  3500   |   1678991.2 /mC
        3    | 30282.001 Hz  |   1457956.6 /mC  | 1514.100 Hz  |  16411780  |    20   |   1460603.6 /mC
        4    | 65661.37 Hz  |   3161330.9 /mC  |    8.208 Hz  |  35586154  |  8000   |   3167070.5 /mC
        5    | 18.776126 Hz  |       904.0 /mC  |   18.776 Hz  |     10176  |     1   |       905.6 /mC
        8    | 1024.0 Hz  |     49301.5 /mC  |    0.016 Hz  |    554972  | 65535   |     49391.0 /mC
        output                      1865.591 Hz
    Av. deadtime from accepted triggers = 0.2444
    Av. deadtime from gated scalers = 0.3939
    Accepted triggers  = 1011085.00000
    Rate of Left Arm Pulser for electronic DT  = 10.172247
    Rate of Right Arm Pulser for electronic DT  = 10.170401
    Rate of Left Arm Pulser&trig for electronic DT  = 10.146415
    Rate of Right Arm Pulser&trig for electronic DT  = 10.170401
    Left Arm Electronic DT  = 0.0025394522
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 177840.84
    Rate of Right Arm Strobe  = 86256.763
        Signal     |    Charge   (C)   
       upstream    |    0.0113737     
       upstream 3x |    0.0113562     
       upstream 10x|    0.0114173     
      downstream   |    0.0110988   
     downstream 3x |    0.0111572   
     downstream 10x|    0.0111445    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1299 at Sat Jan 13 10:26:17 EST 2001
    Right Arm D1 momentum                    : 0.705999
    Right Arm arm angle                      : 56.6435
    Left Arm D1 momentum                      : 0.706003
    Left Arm arm angle                        : 56.6675
    Tiefenbach Hall A energy                : 1173.62
    Right Arm arm mispointing (HPT)          : 2.44851
    Left Arm arm mispointing (HPT)            : -1.15925
    Right Arm Q1 power supply current        : 530.88
    Right Arm Q1 momentum                    : 0.706019
    Right Arm Q1 gauss meter                 : -0.013289
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 303.984
    Right Arm Q2 momentum                    : 0.706337
    Right Arm Q2 gauss meter                 : 0.15993
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 241.231
    Right Arm D1 momentum                    : 0.706001
    Right Arm D1 NMR                         : 0.261988
    Right Arm Q3 power supply current        : 280.962
    Right Arm Q3 momentum                    : 0.706098
    Right Arm Q3 gauss meter                 : 0.12593
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 530.985
    Left Arm Q1 momentum                      : 0.705786
    Left Arm Q1 gauss meter                   : 0.04564
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 303.863
    Left Arm Q2 momentum                      : 0.705675
    Left Arm Q2 gauss meter                   : -0.16078
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 235.61
    Left Arm D1 momentum                      : 0.706004
    Left Arm D1 NMR                           : 0.261458
    Left Arm Q3 power supply current          : 281.161
    Left Arm Q3 momentum                      : 0.706225
    Left Arm Q3 gauss meter                   : 0.14117
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 23.977
    Current on Unser monitor                : 36.7302
    Current on Upstream bcm                 : 23.8147
    Current on Downstream bcm               : 24.1393
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 66.6713
    MBSY1c Hall A Beam energy               : 1174.57
    MBSY1c magnet current (amp)             : 48.6672
    MBSY1c Bdl                              : 293115
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 1173.62
    Tiefenbach Hall C energy                : 3395.41
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00164327
    IPM1H04A.XPOS                           : 0.0485876
    IPM1H04A.YPOS                           : 0.157811
    IPM1H04B.XPOS                           : -0.173912
    IPM1H04B.YPOS                           : 0.0861765
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617041
     HacR_HPM_LVDT:VALr                     : -4779
     HacR_VPM_LVDT:VALr                     : 619
     HacR_HPE1313A:0_Ch58                   : -0.514648
     HacR_HPE1313A:0_Ch55                   : 22.4609
     HacR_HPE1313A:0_Ch54                   : -0.82373
     HacR_alignROLL                         : -0.343644
     HacR_alignPITCH                        : -0.0392868
     HacR_alignHPT                          : 2.44879
     HacL_HPM_LVDT:VALr                     : -2317
     HacL_VPM_LVDT:VALr                     : -431
     HacL_HPE1313A:0_Ch58                   : -0.304688
     HacL_HPE1313A:0_Ch55                   : 23.5352
     HacL_HPE1313A:0_Ch54                   : -0.351074
     HacL_alignROLL                         : 0.0186092
     HacL_alignPITCH                        : 0.0277133
     HacL_alignHPT                          : -1.15568
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 32
    haL3_Fan_frequency_R                     : 31.7303
    haH2_P_Fill_Target_R                     : 23
    haH2_P_Exhaust_R                         : 23.45
    haH2_P_Fill_Bottle_R                     : 23.43
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30.14
    haD2_P_Exhaust_R                         : 20.73
    haD2_P_Fill_Bottle_R                     : 40.99
    haD2_DP_Fill_Exhaust_R                   : 0.0759
    haSC200_6_Sensor_1_R                     : 242.51
    haSC200_6_Sensor_2_R                     : 15.97
    haSC200_6_Sensor_3_R                     : 3.19
    haSC200_6_Sensor_4_R                     : 39.91
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 92.89
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 95.2
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 94.23
    haITC502_5_Sensor_3_R                    : 269
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.85
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 197
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON