Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 23:13:43 on January 15, 2001
Entry number 54796
keyword=End_of_Run_1365
****************************
Run Number: 1365
End of Run Comment:
RunType=Pulser,Tar=absence,Rad=out,comment=cosmic,mode=singles,Lmom=3.359,Rmom=-2.99,Ene=1.173,Angle_R=36.488,Angle_L=22.055
Time of run = 0.64804687 min
Av. current (on 3x) = 0.0077154914 uA
Av. current (on 1x) = 0.033433796 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 0.0013 | 0.0003 | 0.0008
up-down (mC)| 0.0043 | -0.0003 | 0.0006
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 17.385574 Hz | 2253333.3 /mC | 17.386 Hz | 676 | 1 | 520000.0 /mC
2 | 1010.8837 Hz | 131020000.0 /mC | 0.505 Hz | 39306 | 2000 | 30235385.0 /mC
3 | 18.234278 Hz | 2363333.3 /mC | 18.234 Hz | 709 | 1 | 545384.6 /mC
4 | 713.1943 Hz | 92436667.0 /mC | 0.357 Hz | 27731 | 2000 | 21331538.0 /mC
5 | 10.133012 Hz | 1313333.3 /mC | 10.133 Hz | 394 | 1 | 303076.9 /mC
8 | 1024.0 Hz | 132720000.0 /mC | 0.016 Hz | 39816 | 65535 | 30627692.0 /mC
output 26.156 Hz
Av. deadtime from accepted triggers = 0.0079
Av. deadtime from gated scalers = -0.2200
Accepted triggers = 1017.00000
Rate of Left Arm Pulser for electronic DT = 10.133012
Rate of Right Arm Pulser for electronic DT = 9.8758289
Rate of Left Arm Pulser&trig for electronic DT = 10.133012
Rate of Right Arm Pulser&trig for electronic DT = 9.8758289
Left Arm Electronic DT = 0.0
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 1395.6295
Rate of Right Arm Strobe = 1744.1897
Signal | Charge (C)
upstream | 0.0000034
upstream 3x | 0.0000002
upstream 10x| 0.0000011
downstream | -0.0000009
downstream 3x | 0.0000005
downstream 10x| 0.0000005
****************************
End-of-run EPICS data for Run Number 1365 at Mon Jan 15 17:52:17 EST 2001
Right Arm D1 momentum : 0
Right Arm arm angle : 31.122
Left Arm D1 momentum : 0
Left Arm arm angle : 27.3454
Tiefenbach Hall A energy : 5621.35
Right Arm arm mispointing (HPT) : -1.77619
Left Arm arm mispointing (HPT) : 5.07759
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 3.14e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.304093
Right Arm Q2 momentum : 0.000245512
Right Arm Q2 gauss meter : -0.000272
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.64116
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.06439
Right Arm Q3 power supply current : 0.146117
Right Arm Q3 momentum : 0.000552715
Right Arm Q3 gauss meter : -0.0001829
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0003473
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.140795
Left Arm Q2 momentum : 0.000531403
Left Arm Q2 gauss meter : 0.0001208
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 0.133723
Left Arm D1 momentum : 0
Left Arm D1 NMR : 1.08913
Left Arm Q3 power supply current : 1.93528
Left Arm Q3 momentum : 0.00486107
Left Arm Q3 gauss meter : 0.0008024
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0432214
Current on Unser monitor : 11.7012
Current on Upstream bcm : 0.0528863
Current on Downstream bcm : 0.0335151
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00142881
MBSY1c Hall A Beam energy : 5633.03
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.40573e+06
MBSY3c Hall C Beam energy : 3403.8
Tiefenbach Hall A energy : 5621.35
Tiefenbach Hall C energy : 3394.57
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -901
HacR_VPM_LVDT:VALr : 238
HacR_HPE1313A:0_Ch58 : -0.559082
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.787598
HacR_alignROLL : -0.306452
HacR_alignPITCH : 0.0028654
HacR_alignHPT : -1.82355
HacL_HPM_LVDT:VALr : -7879
HacL_VPM_LVDT:VALr : 1116
HacL_HPE1313A:0_Ch58 : -0.154785
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : -0.236816
HacL_alignROLL : 0.122656
HacL_alignPITCH : -0.105658
HacL_alignHPT : 5.01176
haBDSPOS : -44998
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 27
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 45.27
haH2_P_Exhaust_R : 45.68
haH2_P_Fill_Bottle_R : 45.58
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : 29.88
haD2_P_Exhaust_R : 44.79
haD2_P_Fill_Bottle_R : 88.89
haD2_DP_Fill_Exhaust_R : 0.0766
haSC200_6_Sensor_1_R : 241.88
haSC200_6_Sensor_2_R : 23.27
haSC200_6_Sensor_3_R : 2.71
haSC200_6_Sensor_4_R : 39.63
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 94.98
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 194
haITC502_4_Sensor_2_R : 225.1
haITC502_4_Sensor_3_R : 221.7
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 280.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 29.67
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 75
Laser power Hall A : 57
Half-wave plate (off=out) : ON