User name adev
Log entry time 18:47:04 on January 16, 2001
Entry number 54833
keyword=Start_Run_1384_RunType=Optics,Tar=9foil-12C,Rad=out,comment=,mode=singles,Lmom=3.359,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=27.345
Beginning-of-run EPICS data for Run Number 1384 at Tue Jan 16 18:46:54 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=50,ps3=1,ps4=50,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 2248.23
Right Arm Q1 momentum : 2.98992
Right Arm Q1 gauss meter : -0.05587
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1287.02
Right Arm Q2 momentum : 2.99051
Right Arm Q2 gauss meter : 0.6756
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1072.64
Right Arm D1 momentum : 2.99
Right Arm D1 NMR : 1.10955
Right Arm Q3 power supply current : 1189.75
Right Arm Q3 momentum : 2.99002
Right Arm Q3 gauss meter : 0.5334
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.39
Left Arm Q1 momentum : 3.3594
Left Arm Q1 gauss meter : 0.21426
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.34
Left Arm Q2 momentum : 3.3589
Left Arm Q2 gauss meter : -0.7608
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.04
Left Arm D1 momentum : 3.359
Left Arm D1 NMR : 1.24405
Left Arm Q3 power supply current : 1337.37
Left Arm Q3 momentum : 3.35923
Left Arm Q3 gauss meter : 0.6665
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 25.5953
Current on Unser monitor : 35.7667
Current on Upstream bcm : 26.0077
Current on Downstream bcm : 25.1828
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 70.303
Beam energy : 5625.01
MBSY1c magnet current (amp) : 235.092
Radiator 5V Linear Supply : 5.116
Radiator Encoder : 0.517705
haBDSPOS : 2.50444e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 39.5
haL3_Fan_frequency_R : 49
haSC200_6_Sensor_1_R : 241.86
haSC200_6_Sensor_2_R : 18.21
haSC200_6_Sensor_3_R : 2.73
haSC200_6_Sensor_4_R : 39.65
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 126.9
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 99.88
haITC502_5_Sensor_2_R : 99.54
haITC502_5_Sensor_3_R : 274.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.39
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -895
HacR_VPM_LVDT:VALr : 83
HacR_HPE1313A:0_Ch58 : -0.547852
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.772461
HacR_alignROLL : -0.290584
HacR_alignPITCH : -0.00901484
HacR_alignHPT : -1.839
HacL_HPM_LVDT:VALr : -7947
HacL_VPM_LVDT:VALr : 988
HacL_HPE1313A:0_Ch58 : -0.15332
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.23877
HacL_alignROLL : 0.121103
HacL_alignPITCH : -0.107189
HacL_alignHPT : 5.08737
Right Arm Angle Floor Angle : 31
Right Arm Angle Vernier : -15.1
Right Arm Scattering Angle : 31.1224
Left Arm Angle Floor Angle : 27.5
Left Arm Angle Vernier : 10.2
Left Arm Scattering Angle : 27.3453
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 287
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88