    User name adev

    Log entry time 15:42:01 on January 18, 2001

    Entry number 55028

    keyword=End_of_Run_1458
    ****************************
     Run Number: 1458
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=singles-Kin16(trigger-pid-pion),mode=singles,Lmom=2.99,Rmom=-2.99,Ene=5.617,Angle_R=31.122,Angle_L=31.11
    
    
    Time of run = 13.905924 min
    Av. current (on 3x) = 32.792857 uA
    Av. current (on 1x) = 32.726699 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   27.3057  |   27.3609  |   27.4230
    up-down    (mC)|    0.6728  |    0.5879  |    0.7356
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 671.25227 Hz  |     20469.5 /mC  |  671.252 Hz  |    560063  |     1   |     20510.8 /mC
        2      | 57557.792 Hz  |   1755193.0 /mC  |   10.465 Hz  |  48023659  |  5500   |   1758741.2 /mC
        3      | 921.13017 Hz  |     28089.4 /mC  |  921.130 Hz  |    768550  |     1   |     28146.1 /mC
        4      | 93367.123 Hz  |   2847178.6 /mC  |   10.374 Hz  |  77901370  |  9000   |   2852934.4 /mC
        5      | 12.085976 Hz  |       368.6 /mC  |   12.086 Hz  |     10084  |     1   |       369.3 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.912854 Hz  |        58.3 /mC  |    1.913 Hz  | 1596.0  |     1   |        58.4 /mC
        8    | 1024.0 Hz  |     31226.3 /mC  |    0.016 Hz  |    854380  | 65535   |     31289.4 /mC
        output                      1211.590 Hz
    Av. deadtime from accepted triggers = 0.2433
    Av. deadtime from gated scalers = 0.2491
    Accepted triggers  = 1010897.00000
    Rate of Left Arm Pulser for electronic DT  = 10.173122
    Rate of Right Arm Pulser for electronic DT  = 10.161137
    Rate of Left Arm Pulser&trig for electronic DT  = 10.170725
    Rate of Right Arm Pulser&trig for electronic DT  = 10.161137
    Left Arm Electronic DT  = 0.00023562677
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 158824.79
    Rate of Right Arm Strobe  = 86841.951
        Signal     |    Charge   (C)   
       upstream    |    0.0276421     
       upstream 3x |    0.0276549     
       upstream 10x|    0.0277908     
      downstream   |    0.0269693   
     downstream 3x |    0.0270670   
     downstream 10x|    0.0270552    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1458 at Thu Jan 18 15:41:49 EST 2001
    Right Arm D1 momentum                    : 2.99
    Right Arm arm angle                      : 31.1216
    Left Arm D1 momentum                      : 2.98999
    Left Arm arm angle                        : 31.0739
    Tiefenbach Hall A energy                : 5614.96
    Right Arm arm mispointing (HPT)          : -1.71573
    Left Arm arm mispointing (HPT)            : 5.29257
    Right Arm Q1 power supply current        : 2248.16
    Right Arm Q1 momentum                    : 2.98983
    Right Arm Q1 gauss meter                 : -0.05584
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1286.66
    Right Arm Q2 momentum                    : 2.98968
    Right Arm Q2 gauss meter                 : 0.6755
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1072.63
    Right Arm D1 momentum                    : 2.99
    Right Arm D1 NMR                         : 1.10955
    Right Arm Q3 power supply current        : 1189.59
    Right Arm Q3 momentum                    : 2.9896
    Right Arm Q3 gauss meter                 : 0.5334
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2249.66
    Left Arm Q1 momentum                      : 2.99025
    Left Arm Q1 gauss meter                   : 0.19076
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1287.57
    Left Arm Q2 momentum                      : 2.99017
    Left Arm Q2 gauss meter                   : -0.6778
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1045.77
    Left Arm D1 momentum                      : 2.98999
    Left Arm D1 NMR                           : 1.10713
    Left Arm Q3 power supply current          : 1190.46
    Left Arm Q3 momentum                      : 2.9902
    Left Arm Q3 gauss meter                   : 0.5938
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 33.5981
    Current on Unser monitor                : 44.3405
    Current on Upstream bcm                 : 33.6046
    Current on Downstream bcm               : 33.5915
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 74.8374
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.96
    Tiefenbach Hall C energy                : 3395.44
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.000447005
    IPM1H04A.XPOS                           : -0.209902
    IPM1H04A.YPOS                           : 0.03199
    IPM1H04B.XPOS                           : -0.0399735
    IPM1H04B.YPOS                           : -0.0302833
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -1007
     HacR_VPM_LVDT:VALr                     : 50
     HacR_HPE1313A:0_Ch58                   : -0.543457
     HacR_HPE1313A:0_Ch55                   : 22.5098
     HacR_HPE1313A:0_Ch54                   : -0.768066
     HacR_alignROLL                         : -0.286956
     HacR_alignPITCH                        : -0.0123555
     HacR_alignHPT                          : -1.71601
     HacL_HPM_LVDT:VALr                     : -8107
     HacL_VPM_LVDT:VALr                     : 692
     HacL_HPE1313A:0_Ch58                   : -0.149414
     HacL_HPE1313A:0_Ch55                   : 23.3398
     HacL_HPE1313A:0_Ch54                   : -0.266113
     HacL_alignROLL                         : 0.0970243
     HacL_alignPITCH                        : -0.110903
     HacL_alignHPT                          : 5.29264
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 38.5
    haL3_Fan_frequency_R                     : 49.5
    haH2_P_Fill_Target_R                     : 23.71
    haH2_P_Exhaust_R                         : 24.16
    haH2_P_Fill_Bottle_R                     : 24.02
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30.09
    haD2_P_Exhaust_R                         : 21.29
    haD2_P_Fill_Bottle_R                     : 42.06
    haD2_DP_Fill_Exhaust_R                   : 0.0799
    haSC200_6_Sensor_1_R                     : 241.9
    haSC200_6_Sensor_2_R                     : 15.19
    haSC200_6_Sensor_3_R                     : 2.79
    haSC200_6_Sensor_4_R                     : 39.6
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 88.16
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 92.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22.1
    haITC502_5_Sensor_1_R                    : 99.88
    haITC502_5_Sensor_2_R                    : 99.54
    haITC502_5_Sensor_3_R                    : 269.5
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 96.15
    haITC502_6_Sensor_3_R                    : 28.06
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 250
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF