User name S. Sirca
Log entry time 00:00:00 on January23,2001
Entry number 55456
keyword=Cryo targets status
Presently, the temperatures in the cryo-target loops are past the LN2.
The pressures are 45 psi (LH2, PT131) and 24 psi (LD2, PT140).
The first pressure is OK, the second is suspiciously small.
We opened/closed CSV62 (connecting supply to return) and closed/opened
CSV56 (connecting bottle to supply) and nothing changed. Differential
pressure in the loop (DP141) is zero. According to Jian Ping, there are three
possibilities:
- we have lost a lot of gas during venting
- the pressure transducer is broken (unlikely)
- both sides (pipes) leading to/from the valve are frozen (this would be bad)
Night shift: keep an eye on the LD2 loop, but there is not much you can do.
Note: do not touch the relief valve (CSV57).