User name adev
Log entry time 00:56:58 on January 24, 2001
Entry number 55514
keyword=Start_Run_1654_RunType=Other,Tar=LD2-15cm,Rad=out,comment=kin16,mode=coincidence,Lmom=-3.863,Rmom=2.442,Ene=5.617,Angle_R=36.469,Angle_L=22.052
Beginning-of-run EPICS data for Run Number 1654 at Wed Jan 24 00:56:47 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=700,ps3=3,ps4=1400,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 1836.24
Right Arm Q1 momentum : 2.44202
Right Arm Q1 gauss meter : 0.04585
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1050.75
Right Arm Q2 momentum : 2.44153
Right Arm Q2 gauss meter : -0.5526
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 860.265
Right Arm D1 momentum : 2.442
Right Arm D1 NMR : 0.906196
Right Arm Q3 power supply current : 971.95
Right Arm Q3 momentum : 2.44264
Right Arm Q3 gauss meter : -0.4357
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 2906.33
Left Arm Q1 momentum : 3.8631
Left Arm Q1 gauss meter : -0.24566
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1663.32
Left Arm Q2 momentum : 3.86281
Left Arm Q2 gauss meter : 0.8756
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1426.95
Left Arm D1 momentum : 3.863
Left Arm D1 NMR : 1.43107
Left Arm Q3 power supply current : 1538
Left Arm Q3 momentum : 3.86316
Left Arm Q3 gauss meter : -0.7669
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 9.97264
Current on Unser monitor : 20.2649
Current on Upstream bcm : 9.97796
Current on Downstream bcm : 9.96731
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 55.2986
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 4.86691
Radiator Encoder : 0.549451
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 26
haL3_Fan_frequency_R : 44
haSC200_6_Sensor_1_R : 241.64
haSC200_6_Sensor_2_R : 15.46
haSC200_6_Sensor_3_R : 2.66
haSC200_6_Sensor_4_R : 39.53
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 98.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 86.2
haITC502_5_Sensor_2_R : 84.4
haITC502_5_Sensor_3_R : 269.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 28.1
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.617139
HacR_HPM_LVDT:VALr : -4470
HacR_VPM_LVDT:VALr : 298
HacR_HPE1313A:0_Ch58 : -0.529785
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.868652
HacR_alignROLL : -0.388502
HacR_alignPITCH : -0.0244746
HacR_alignHPT : 2.19174
HacL_HPM_LVDT:VALr : -7136
HacL_VPM_LVDT:VALr : 2059
HacL_HPE1313A:0_Ch58 : -0.117188
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.125977
HacL_alignROLL : 0.221575
HacL_alignPITCH : -0.140016
HacL_alignHPT : 4.1352
Right Arm Angle Floor Angle : 36
Right Arm Angle Vernier : 50
Right Arm Scattering Angle : 36.4703
Left Arm Angle Floor Angle : 22
Left Arm Angle Vernier : 45
Left Arm Scattering Angle : 22.0524
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A :
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88