    User name adev

    Log entry time 15:28:47 on January 27, 2001

    Entry number 55863

    keyword=Start_Run_1774_RunType=Optics,Tar=LH2-15cm,Rad=out,comment=kinematics_4,mode=coincidence,Lmom=2.542,Rmom=-2.504,Ene=5.617,Angle_R=23.451,Angle_L=16.95
    Beginning-of-run EPICS data for Run Number 1774 at Sat Jan 27 15:28:35 EST 2001
    ; (Integer!) prescale factors for runs.
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=750,ps2=7500,ps3=24000,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
    ;ps1=1,ps2=7500,ps3=10,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    Right Arm Q1 power supply current        : 1882.82
    Right Arm Q1 momentum                    : 2.50397
    Right Arm Q1 gauss meter                 : -0.04683
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1077.69
    Right Arm Q2 momentum                    : 2.50412
    Right Arm Q2 gauss meter                 : 0.566
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 881.46
    Right Arm D1 momentum                    : 2.504
    Right Arm D1 NMR                         : 0.929204
    Right Arm Q3 power supply current        : 996.316
    Right Arm Q3 momentum                    : 2.5045
    Right Arm Q3 gauss meter                 : 0.4469
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1912.57
    Left Arm Q1 momentum                      : 2.5422
    Left Arm Q1 gauss meter                   : 0.16225
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1094.42
    Left Arm Q2 momentum                      : 2.54161
    Left Arm Q2 gauss meter                   : -0.5767
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 877.206
    Left Arm D1 momentum                      : 2.542
    Left Arm D1 NMR                           : 0.940893
    Left Arm Q3 power supply current          : 1012
    Left Arm Q3 momentum                      : 2.54195
    Left Arm Q3 gauss meter                   : 0.5052
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 84.33
    Current on Unser monitor                : 94.5306
    Current on Upstream bcm                 : 84.4094
    Current on Downstream bcm               : 84.2506
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 130.166
    Beam energy                             : 5626.62
    MBSY1c magnet current (amp)             : 235.16
     Radiator 5V Linear Supply              : 5.01343
     Radiator Encoder                       : 0.15873
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 68
    haL3_Fan_frequency_R                     : 19.5
    haSC200_6_Sensor_1_R                     : 241.46
    haSC200_6_Sensor_2_R                     : 14.91
    haSC200_6_Sensor_3_R                     : 2.58
    haSC200_6_Sensor_4_R                     : 39.53
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_4_Sensor_1_R                    : 94.3
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.28
    haITC502_5_Sensor_2_R                    : 83.21
    haITC502_5_Sensor_3_R                    : 266.8
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.95
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -3623
     HacR_VPM_LVDT:VALr                     : -302
     HacR_HPE1313A:0_Ch58                   : -0.540527
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.735352
     HacR_alignROLL                         : -0.253808
     HacR_alignPITCH                        : -0.0151814
     HacR_alignHPT                          : 1.21878
     HacL_HPM_LVDT:VALr                     : -7253
     HacL_VPM_LVDT:VALr                     : 2049
     HacL_HPE1313A:0_Ch58                   : -0.13916
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : -0.0112305
     HacL_alignROLL                         : 0.330476
     HacL_alignPITCH                        : -0.140983
     HacL_alignHPT                          : 4.21254
    Right Arm Angle Floor Angle               : 23
    Right Arm Angle Vernier                   : 45.6
    Right Arm Scattering Angle                : 23.4516
    Left Arm Angle Floor Angle                 : 17
    Left Arm Angle Vernier                     : 27.4
    Left Arm Scattering Angle                  : 16.9504
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 457
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF
    Survey X offset bpmA                      : -0.32
    Survey Y offset bpmA                      : -0.35
    Survey X offset bpmB                      : -0.05
    Survey Y offset bpmB                      : -0.88