Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 03:07:05 on January 28, 2001
Entry number 55918
keyword=Start_Run_1798_RunType=Pulser,Tar=LH2-15cm,Rad=out,comment=Test
Beginning-of-run EPICS data for Run Number 1798 at Sun Jan 28 03:06:55 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=7500,ps3=24000,ps4=7500,ps5=1,ps6=65535,ps7=65535,ps8=3
Right Arm Q1 power supply current : 1882.82
Right Arm Q1 momentum : 2.50397
Right Arm Q1 gauss meter : -0.04684
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1077.52
Right Arm Q2 momentum : 2.50372
Right Arm Q2 gauss meter : 0.566
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 881.466
Right Arm D1 momentum : 2.504
Right Arm D1 NMR : 0.929204
Right Arm Q3 power supply current : 996.435
Right Arm Q3 momentum : 2.50418
Right Arm Q3 gauss meter : 0.4468
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1912.47
Left Arm Q1 momentum : 2.54206
Left Arm Q1 gauss meter : 0.16225
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1094.54
Left Arm Q2 momentum : 2.54189
Left Arm Q2 gauss meter : -0.5767
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 877.205
Left Arm D1 momentum : 2.54199
Left Arm D1 NMR : 0.940891
Left Arm Q3 power supply current : 1012.15
Left Arm Q3 momentum : 2.54234
Left Arm Q3 gauss meter : 0.5053
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0400684
Current on Unser monitor : 10.399
Current on Upstream bcm : 0.0467046
Current on Downstream bcm : 0.0334322
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00142881
Beam energy : 5626.62
MBSY1c magnet current (amp) : 235.16
Radiator 5V Linear Supply : 5.00122
Radiator Encoder : 0.188034
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66.5
haL3_Fan_frequency_R : 19.5
haSC200_6_Sensor_1_R : 241.58
haSC200_6_Sensor_2_R : 14.91
haSC200_6_Sensor_3_R : 2.71
haSC200_6_Sensor_4_R : 39.6
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 93.8
haITC502_4_Sensor_2_R : 18.8
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 85.06
haITC502_5_Sensor_2_R : 82.95
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.92
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.61709
HacR_HPM_LVDT:VALr : -3630
HacR_VPM_LVDT:VALr : -262
HacR_HPE1313A:0_Ch58 : -0.538574
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.735352
HacR_alignROLL : -0.253869
HacR_alignPITCH : -0.0169105
HacR_alignHPT : 1.22665
HacL_HPM_LVDT:VALr : -7263
HacL_VPM_LVDT:VALr : 2083
HacL_HPE1313A:0_Ch58 : -0.137695
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0126953
HacL_alignROLL : 0.329235
HacL_alignPITCH : -0.142005
HacL_alignHPT : 4.22431
Right Arm Angle Floor Angle : 23
Right Arm Angle Vernier : 45.6
Right Arm Scattering Angle : 23.4515
Left Arm Angle Floor Angle : 17
Left Arm Angle Vernier : 27.4
Left Arm Scattering Angle : 16.9503
Wien angle : 1.37
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -3.63
Wien field : 0
Laser attenuation Hall A : 140
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88