    User name adev

    Log entry time 02:57:08 on January 29, 2001

    Entry number 56035

    keyword=End_of_Run_1841
    ****************************
     Run Number: 1841
    End of Run Comment:
    RunType=Optics,Tar=9foil-12C,Rad=out,comment=kin6 production,mode=coincidence,Lmom=1.93,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=14.644
    
    Time of run = 3.643392 min
    Av. current (on 3x) = 24.286434 uA
    Av. current (on 1x) = 24.219189 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.2944  |    5.3091  |    5.3168
    up-down    (mC)|   -0.0018  |    0.0105  |    0.0184
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 1109.3737 Hz  |     45678.7 /mC  | 1109.374 Hz  |    242513  |     1   |     45805.6 /mC
        2      | 8633.7494 Hz  |    355496.8 /mC  |    1.151 Hz  |   1887368  |  7500   |    356483.8 /mC
        3      | 34414.116 Hz  |   1417009.9 /mC  | 3441.412 Hz  |   7523047  |    10   |   1420944.2 /mC
        4      | 12598.347 Hz  |    518740.1 /mC  |    1.680 Hz  |   2754043  |  7500   |    520180.4 /mC
        5      | 14.130605 Hz  |       581.8 /mC  |   14.131 Hz  |      3089  |     1   |       583.4 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 3.952361 Hz  |       162.7 /mC  |    3.952 Hz  | 864.00003  |     1   |       163.2 /mC
        8    | 1024.0 Hz  |     42163.5 /mC  |    0.016 Hz  |    223850  | 65535   |     42280.5 /mC
        output                      3501.590 Hz
    Av. deadtime from accepted triggers = 0.2308
    Av. deadtime from gated scalers = 0.4968
    Accepted triggers  = 765460.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178244
    Rate of Right Arm Pulser for electronic DT  = 10.159946
    Rate of Left Arm Pulser&trig for electronic DT  = 10.146223
    Rate of Right Arm Pulser&trig for electronic DT  = 10.159946
    Left Arm Electronic DT  = 0.0031460674
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 71780.038
    Rate of Right Arm Strobe  = 9104.8031
        Signal     |    Charge   (C)   
       upstream    |    0.0052935     
       upstream 3x |    0.0053144     
       upstream 10x|    0.0053260     
      downstream   |    0.0052953   
     downstream 3x |    0.0053039   
     downstream 10x|    0.0053076    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1841 at Mon Jan 29 02:56:58 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.1222
    Left Arm D1 momentum                      : 1.92999
    Left Arm arm angle                        : 14.6436
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : -1.71952
    Left Arm arm mispointing (HPT)            : 4.06034
    Right Arm Q1 power supply current        : 2285.08
    Right Arm Q1 momentum                    : 3.03893
    Right Arm Q1 gauss meter                 : -0.05675
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1307.88
    Right Arm Q2 momentum                    : 3.03898
    Right Arm Q2 gauss meter                 : 0.6865
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.62
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.38
    Right Arm Q3 momentum                    : 3.03934
    Right Arm Q3 gauss meter                 : 0.5422
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1451.97
    Left Arm Q1 momentum                      : 1.92997
    Left Arm Q1 gauss meter                   : 0.12349
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 831.012
    Left Arm Q2 momentum                      : 1.92989
    Left Arm Q2 gauss meter                   : -0.4382
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 652.587
    Left Arm D1 momentum                      : 1.93
    Left Arm D1 NMR                           : 0.714181
    Left Arm Q3 power supply current          : 768.205
    Left Arm Q3 momentum                      : 1.92967
    Left Arm Q3 gauss meter                   : 0.3837
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 24.1665
    Current on Unser monitor                : 34.455
    Current on Upstream bcm                 : 24.2471
    Current on Downstream bcm               : 24.1252
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 24.1476
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.91
    Tiefenbach Hall C energy                : 3396.15
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.00151658
    IPM1H04A.XPOS                           : 1.75177
    IPM1H04A.YPOS                           : 0.0794192
    IPM1H04B.XPOS                           : 2.00555
    IPM1H04B.YPOS                           : -0.0217467
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -986
     HacR_VPM_LVDT:VALr                     : -196
     HacR_HPE1313A:0_Ch58                   : -0.507324
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.760742
     HacR_alignROLL                         : -0.279383
     HacR_alignPITCH                        : -0.0457721
     HacR_alignHPT                          : -1.71843
     HacL_HPM_LVDT:VALr                     : -7128
     HacL_VPM_LVDT:VALr                     : 1723
     HacL_HPE1313A:0_Ch58                   : -0.170898
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : 0.0112305
     HacL_alignROLL                         : 0.351929
     HacL_alignPITCH                        : -0.112243
     HacL_alignHPT                          : 4.06034
    haBDSPOS                                 : 2.50444e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 65.5
    haL3_Fan_frequency_R                     : 15
    haH2_P_Fill_Target_R                     : 23.02
    haH2_P_Exhaust_R                         : 23.32
    haH2_P_Fill_Bottle_R                     : 23.34
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 30
    haD2_P_Exhaust_R                         : 18.46
    haD2_P_Fill_Bottle_R                     : 36.49
    haD2_DP_Fill_Exhaust_R                   : 0.0769
    haSC200_6_Sensor_1_R                     : 241.41
    haSC200_6_Sensor_2_R                     : 14.8
    haSC200_6_Sensor_3_R                     : 2.54
    haSC200_6_Sensor_4_R                     : 39.55
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 93.7
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 85.06
    haITC502_5_Sensor_2_R                    : 82.92
    haITC502_5_Sensor_3_R                    : 270.1
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.03
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.617041
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 224
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF