    User name adev

    Log entry time 12:07:30 on January 29, 2001

    Entry number 56123

    keyword=End_of_Run_1871
    ****************************
     Run Number: 1871
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kin9 15 cm LH2 data at kin 9,mode=coincidence,Lmom=1.89,Rmom=-3.039,Ene=5.617,Angle_R=19.122,Angle_L=12.521
    
    
    Time of run = 15.9125 min
    Av. current (on 3x) = 56.854046 uA
    Av. current (on 1x) = 56.719455 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   54.1529  |   54.2814  |   49.6450
    up-down    (mC)|   -0.1056  |    0.1409  |   -1.1382
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 12332.836 Hz  |    216921.0 /mC  |   16.444 Hz  |  11774775  |   750   |    217435.7 /mC
        2      | 45425.769 Hz  |    798989.2 /mC  |    6.057 Hz  |  43370253  |  7500   |    800885.1 /mC
        3      | 600397.46 Hz  |  10560330.0 /mC  |   25.017 Hz  | 573229480  | 24000   |  10585388.0 /mC
        4      | 101617.53 Hz  |   1787340.3 /mC  |   13.549 Hz  |  97019332  |  7500   |   1791581.5 /mC
        5      | 863.18513 Hz  |     15182.5 /mC  |  863.185 Hz  |    824126  |     1   |     15218.5 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 853.00969 Hz  |     15003.5 /mC  |  853.010 Hz  | 814411.0  |     1   |     15039.1 /mC
        8    | 1024.0 Hz  |     18011.0 /mC  |    0.016 Hz  |    977664  | 65535   |     18053.8 /mC
        output                       790.203 Hz
    Av. deadtime from accepted triggers = 0.1440
    Av. deadtime from gated scalers = 0.1878
    Accepted triggers  = 754446.00000
    Rate of Left Arm Pulser for electronic DT  = 10.175439
    Rate of Right Arm Pulser for electronic DT  = 10.175439
    Rate of Left Arm Pulser&trig for electronic DT  = 9.7962817
    Rate of Right Arm Pulser&trig for electronic DT  = 10.174391
    Left Arm Electronic DT  = 0.037261966
    Right Arm Electronic DT  = 0.00010293361
    Rate of Left Strobe  = 927681.6
    Rate of Right Arm Strobe  = 54038.061
        Signal     |    Charge   (C)   
       upstream    |    0.0541001     
       upstream 3x |    0.0543519     
       upstream 10x|    0.0490759     
      downstream   |    0.0542057   
     downstream 3x |    0.0542110   
     downstream 10x|    0.0502141    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1871 at Mon Jan 29 12:07:20 EST 2001
    Right Arm D1 momentum                    : 3.039
    Right Arm arm angle                      : 19.1223
    Left Arm D1 momentum                      : 1.88999
    Left Arm arm angle                        : 12.5215
    Tiefenbach Hall A energy                : 5614.91
    Right Arm arm mispointing (HPT)          : -1.73133
    Left Arm arm mispointing (HPT)            : 3.92846
    Right Arm Q1 power supply current        : 2285.08
    Right Arm Q1 momentum                    : 3.03893
    Right Arm Q1 gauss meter                 : -0.05675
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1308.02
    Right Arm Q2 momentum                    : 3.0393
    Right Arm Q2 gauss meter                 : 0.6866
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 1092.61
    Right Arm D1 momentum                    : 3.039
    Right Arm D1 NMR                         : 1.12774
    Right Arm Q3 power supply current        : 1209.18
    Right Arm Q3 momentum                    : 3.03883
    Right Arm Q3 gauss meter                 : 0.5422
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1421.88
    Left Arm Q1 momentum                      : 1.88996
    Left Arm Q1 gauss meter                   : 0.12096
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 813.886
    Left Arm Q2 momentum                      : 1.89012
    Left Arm Q2 gauss meter                   : -0.4291
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 638.219
    Left Arm D1 momentum                      : 1.89
    Left Arm D1 NMR                           : 0.699389
    Left Arm Q3 power supply current          : 752.529
    Left Arm Q3 momentum                      : 1.89021
    Left Arm Q3 gauss meter                   : 0.3758
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 82.4647
    Current on Unser monitor                : 92.9292
    Current on Upstream bcm                 : 82.6404
    Current on Downstream bcm               : 82.2891
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 82.4402
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.9
    Tiefenbach Hall C energy                : 3396.15
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : -0.00106344
    IPM1H04A.XPOS                           : -0.153441
    IPM1H04A.YPOS                           : 0.118803
    IPM1H04B.XPOS                           : -0.163146
    IPM1H04B.YPOS                           : 0.0271523
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -981
     HacR_VPM_LVDT:VALr                     : -217
     HacR_HPE1313A:0_Ch58                   : -0.503418
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.749512
     HacR_alignROLL                         : -0.268478
     HacR_alignPITCH                        : -0.0498793
     HacR_alignHPT                          : -1.73025
     HacL_HPM_LVDT:VALr                     : -7027
     HacL_VPM_LVDT:VALr                     : 1303
     HacL_HPE1313A:0_Ch58                   : -0.20459
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : 0.0595703
     HacL_alignROLL                         : 0.398477
     HacL_alignPITCH                        : -0.0826293
     HacL_alignHPT                          : 3.92849
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 65
    haL3_Fan_frequency_R                     : 14.5
    haH2_P_Fill_Target_R                     : 24.15
    haH2_P_Exhaust_R                         : 24.46
    haH2_P_Fill_Bottle_R                     : 24.52
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.9
    haD2_P_Exhaust_R                         : 19.39
    haD2_P_Fill_Bottle_R                     : 38.39
    haD2_DP_Fill_Exhaust_R                   : 0.0765
    haSC200_6_Sensor_1_R                     : 241.78
    haSC200_6_Sensor_2_R                     : 14.95
    haSC200_6_Sensor_3_R                     : 2.71
    haSC200_6_Sensor_4_R                     : 39.65
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.27
    haITC502_4_Sensor_1_R                    : 94
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 85.32
    haITC502_5_Sensor_2_R                    : 83.18
    haITC502_5_Sensor_3_R                    : 266.5
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 27.93
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.617139
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 474
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF