    User name adev

    Log entry time 18:18:56 on January 29, 2001

    Entry number 56157

    keyword=End_of_Run_1883
    ****************************
     Run Number: 1883
    End of Run Comment:
    RunType=Optics,Tar=dum-15cm,Rad=out,comment=kin10 optics,mode=coincidence,Lmom=2.521,Rmom=-2.608,Ene=5.615,Angle_R=20.64,Angle_L=16.41
    
    
    Time of run = 6.438151 min
    Av. current (on 3x) = 21.218307 uA
    Av. current (on 1x) = 21.16032 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    8.1740  |    8.1964  |    8.2089
    up-down    (mC)|    0.0010  |    0.0165  |    0.0297
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 1287.862 Hz  |     60695.8 /mC  | 1287.862 Hz  |    497487  |     1   |     60862.1 /mC
        2      | 9034.7498 Hz  |    425799.7 /mC  |    1.205 Hz  |   3490025  |  7500   |    426966.6 /mC
        3      | 12850.882 Hz  |    605650.7 /mC  | 1285.088 Hz  |   4964155  |    10   |    607310.4 /mC
        4      | 10838.583 Hz  |    510812.8 /mC  |    1.445 Hz  |   4186826  |  7500   |    512212.6 /mC
        5      | 12.689979 Hz  |       598.1 /mC  |   12.690 Hz  |      4902  |     1   |       599.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 2.508484 Hz  |       118.2 /mC  |    2.508 Hz  | 968.99987  |     1   |       118.5 /mC
        8    | 1024.0 Hz  |     48260.2 /mC  |    0.016 Hz  |    395560  | 65535   |     48392.5 /mC
        output                      1961.425 Hz
    Av. deadtime from accepted triggers = 0.2381
    Av. deadtime from gated scalers = 0.3117
    Accepted triggers  = 757677.00000
    Rate of Left Arm Pulser for electronic DT  = 10.181495
    Rate of Right Arm Pulser for electronic DT  = 10.147841
    Rate of Left Arm Pulser&trig for electronic DT  = 10.17114
    Rate of Right Arm Pulser&trig for electronic DT  = 10.147841
    Left Arm Electronic DT  = 0.0010170353
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 38971.492
    Rate of Right Arm Strobe  = 9784.7684
        Signal     |    Charge   (C)   
       upstream    |    0.0081745     
       upstream 3x |    0.0082046     
       upstream 10x|    0.0082238     
      downstream   |    0.0081735   
     downstream 3x |    0.0081881   
     downstream 10x|    0.0081941    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 1883 at Mon Jan 29 18:18:46 EST 2001
    Right Arm D1 momentum                    : 2.608
    Right Arm arm angle                      : 19.1034
    Left Arm D1 momentum                      : 2.52101
    Left Arm arm angle                        : 27.8507
    Tiefenbach Hall A energy                : 5614.5
    Right Arm arm mispointing (HPT)          : 1.05759
    Left Arm arm mispointing (HPT)            : 4.30165
    Right Arm Q1 power supply current        : 1961.05
    Right Arm Q1 momentum                    : 2.60801
    Right Arm Q1 gauss meter                 : -0.04877
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1122.36
    Right Arm Q2 momentum                    : 2.60791
    Right Arm Q2 gauss meter                 : 0.5894
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 921.321
    Right Arm D1 momentum                    : 2.608
    Right Arm D1 NMR                         : 0.967798
    Right Arm Q3 power supply current        : 1037.73
    Right Arm Q3 momentum                    : 2.60795
    Right Arm Q3 gauss meter                 : 0.4654
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1896.76
    Left Arm Q1 momentum                      : 2.52117
    Left Arm Q1 gauss meter                   : 0.16093
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1085.69
    Left Arm Q2 momentum                      : 2.52134
    Left Arm Q2 gauss meter                   : -0.5719
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 869.41
    Left Arm D1 momentum                      : 2.52101
    Left Arm D1 NMR                           : 0.933104
    Left Arm Q3 power supply current          : 1003.65
    Left Arm Q3 momentum                      : 2.52098
    Left Arm Q3 gauss meter                   : 0.5011
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 24.3322
    Current on Unser monitor                : 35.1569
    Current on Upstream bcm                 : 24.2796
    Current on Downstream bcm               : 24.4007
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 24.371
    MBSY1c Hall A Beam energy               : 5626.62
    MBSY1c magnet current (amp)             : 235.16
    MBSY1c Bdl                              : 1.40413e+06
    MBSY3c Hall C Beam energy               : 3403.8
    Tiefenbach Hall A energy                : 5614.47
    Tiefenbach Hall C energy                : 3396.15
    Delta(E)/E width (MV_AI_DXWID)          : 0
    IPM1C12.XPOS                            : 0.0181326
    IPM1H04A.XPOS                           : -0.113481
    IPM1H04A.YPOS                           : 0.0944541
    IPM1H04B.XPOS                           : -0.0436533
    IPM1H04B.YPOS                           : 0.0664611
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.61709
     HacR_HPM_LVDT:VALr                     : -3471
     HacR_VPM_LVDT:VALr                     : -230
     HacR_HPE1313A:0_Ch58                   : -0.524902
     HacR_HPE1313A:0_Ch55                   : 22.6562
     HacR_HPE1313A:0_Ch54                   : -0.75
     HacR_alignROLL                         : -0.268538
     HacR_alignPITCH                        : -0.0296122
     HacR_alignHPT                          : 1.05703
     HacL_HPM_LVDT:VALr                     : -7341
     HacL_VPM_LVDT:VALr                     : 1876
     HacL_HPE1313A:0_Ch58                   : -0.15918
     HacL_HPE1313A:0_Ch55                   : 23.3398
     HacL_HPE1313A:0_Ch54                   : 0.0107422
     HacL_alignROLL                         : 0.351153
     HacL_alignPITCH                        : -0.12287
     HacL_alignHPT                          : 4.30206
    haBDSPOS                                 : 1.72635e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 69.5
    haL3_Fan_frequency_R                     : 15
    haH2_P_Fill_Target_R                     : 23.29
    haH2_P_Exhaust_R                         : 23.67
    haH2_P_Fill_Bottle_R                     : 23.69
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 29.85
    haD2_P_Exhaust_R                         : 18.73
    haD2_P_Fill_Bottle_R                     : 37.03
    haD2_DP_Fill_Exhaust_R                   : 0.0768
    haSC200_6_Sensor_1_R                     : 241.46
    haSC200_6_Sensor_2_R                     : 14.91
    haSC200_6_Sensor_3_R                     : 2.56
    haSC200_6_Sensor_4_R                     : 39.56
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.07
    haITC502_4_Sensor_1_R                    : 94.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 85.43
    haITC502_5_Sensor_2_R                    : 83.36
    haITC502_5_Sensor_3_R                    : 269.7
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 28.07
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.61709
    Wien angle                               : 1.37
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -3.63
    Wien field                               : 0
    Laser attenuation Hall A                 : 220
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF