    User name adev

    Log entry time 17:24:02 on March 4, 2001

    Entry number 57662

    keyword=End_of_Run_2478
    ****************************
     Run Number: 2478
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=4_single,mode=singles,Lmom=1.433,Rmom=-1.433,Ene=1.723,Angle_R=24.474,Angle_L=24.434
    
    
    Time of run = 10.471012 min
    Av. current (on 3x) = 8.0592335 uA
    Av. current (on 1x) = 8.025012 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.0418  |    5.0633  |    5.0785
    up-down    (mC)|    0.0039  |   -0.0192  |    0.0005
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 25480.795 Hz  |   3161689.6 /mC  | 1019.232 Hz  |  16008583  |    25   |   3175172.2 /mC
        2      | 28847.727 Hz  |   3579462.8 /mC  |  103.028 Hz  |  18123894  |   280   |   3594726.9 /mC
        3      | 18160.277 Hz  |   2253350.4 /mC  |  726.411 Hz  |  11409389  |    25   |   2262959.5 /mC
        4      | 28460.921 Hz  |   3531467.4 /mC  |  129.368 Hz  |  17880879  |   220   |   3546526.8 /mC
        5      | 48.115373 Hz  |      5970.2 /mC  |   48.115 Hz  |     30229  |     1   |      5995.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 37.936478 Hz  |      4707.2 /mC  |   37.936 Hz  | 23834.0  |     1   |      4727.3 /mC
        8    | 1024.0 Hz  |    127059.2 /mC  |    0.016 Hz  |    643339  | 65535   |    127601.1 /mC
        output                      1610.927 Hz
    Av. deadtime from accepted triggers = 0.2034
    Av. deadtime from gated scalers = 0.2968
    Accepted triggers  = 1012082.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178895
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.167753
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0010946052
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 70480.056
    Rate of Right Arm Strobe  = 60503.521
        Signal     |    Charge   (C)   
       upstream    |    0.0050437     
       upstream 3x |    0.0050537     
       upstream 10x|    0.0050788     
      downstream   |    0.0050398   
     downstream 3x |    0.0050729   
     downstream 10x|    0.0050783    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2478 at Sun Mar  4 17:23:42 EST 2001
    Right Arm D1 momentum                    : 1.433
    Right Arm arm angle                      : 24.4745
    Left Arm D1 momentum                      : 1.43299
    Left Arm arm angle                        : 24.4343
    Tiefenbach Hall A energy                : 1722.69
    Right Arm arm mispointing (HPT)          : -2.0371
    Left Arm arm mispointing (HPT)            : 3.6889
    Right Arm Q1 power supply current        : 1077.61
    Right Arm Q1 momentum                    : 1.43312
    Right Arm Q1 gauss meter                 : -0.02688
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 616.911
    Right Arm Q2 momentum                    : 1.43345
    Right Arm Q2 gauss meter                 : 0.3241
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 489.98
    Right Arm D1 momentum                    : 1.433
    Right Arm D1 NMR                         : 0.531769
    Right Arm Q3 power supply current        : 570.471
    Right Arm Q3 momentum                    : 1.43367
    Right Arm Q3 gauss meter                 : 0.2557
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1078
    Left Arm Q1 momentum                      : 1.43288
    Left Arm Q1 gauss meter                   : 0.09185
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 617.086
    Left Arm Q2 momentum                      : 1.43308
    Left Arm Q2 gauss meter                   : -0.3253
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 480.035
    Left Arm D1 momentum                      : 1.43299
    Left Arm D1 NMR                           : 0.530384
    Left Arm Q3 power supply current          : 570.516
    Left Arm Q3 momentum                      : 1.43303
    Left Arm Q3 gauss meter                   : 0.285
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 8.16902
    Current on Unser monitor                : 13.708
    Current on Upstream bcm                 : 8.13357
    Current on Downstream bcm               : 8.20447
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 63.1374
    MBSY1c Hall A Beam energy               : 1724.44
    MBSY1c magnet current (amp)             : 71.6882
    MBSY1c Bdl                              : 430337
    MBSY3c Hall C Beam energy               : 3406.76
    Tiefenbach Hall A energy                : 1722.69
    Tiefenbach Hall C energy                : 3399.08
    Delta(E)/E width (MV_AI_DXWID)          : 7.06912
    IPM1C12.XPOS                            : 0.00708094
    IPM1H04A.XPOS                           : 1.18118
    IPM1H04A.YPOS                           : 0.689775
    IPM1H04B.XPOS                           : 0.0420737
    IPM1H04B.YPOS                           : -0.0632428
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -715
     HacR_VPM_LVDT:VALr                     : 125
     HacR_HPE1313A:0_Ch58                   : -0.537109
     HacR_HPE1313A:0_Ch55                   : 22.7539
     HacR_HPE1313A:0_Ch54                   : -0.779785
     HacR_alignROLL                         : -0.298551
     HacR_alignPITCH                        : -0.0175587
     HacR_alignHPT                          : -2.03626
     HacL_HPM_LVDT:VALr                     : -6717
     HacL_VPM_LVDT:VALr                     : 1487
     HacL_HPE1313A:0_Ch58                   : -0.147949
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.178711
     HacL_alignROLL                         : 0.17601
     HacL_alignPITCH                        : -0.112583
     HacL_alignHPT                          : 3.68555
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 24.45
    haH2_P_Exhaust_R                         : 25.14
    haH2_P_Fill_Bottle_R                     : 24.94
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 20.87
    haD2_P_Fill_Bottle_R                     : 42.96
    haD2_DP_Fill_Exhaust_R                   : 0.0772
    haSC200_6_Sensor_1_R                     : 241.63
    haSC200_6_Sensor_2_R                     : 24.95
    haSC200_6_Sensor_3_R                     : 37.22
    haSC200_6_Sensor_4_R                     : 40.61
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.03
    haITC502_1_Sensor_2_R                    : 82.21
    haITC502_1_Sensor_3_R                    : 75.57
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 82.1
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 87.84
    haITC502_5_Sensor_2_R                    : 81.72
    haITC502_5_Sensor_3_R                    : 268
    haITC502_6_Sensor_1_R                    : 94.36
    haITC502_6_Sensor_2_R                    : 79.39
    haITC502_6_Sensor_3_R                    : 28.1
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616992
    Wien angle                               : 45.4996
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1016.1
    Wien field                               : 29.657
    Laser attenuation Hall A                 : 130
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF