User name adev
Log entry time 07:52:06 on March 6, 2001
Entry number 57869
keyword=End_of_Run_2567
****************************
Run Number: 2567
End of Run Comment:
RunType=pion_prod,Tar=4He-10cm,Rad=6,comment=coin4,mode=coincidence,Lmom=0.6974,Rmom=-1.433,Ene=1.723,Angle_R=24.472,Angle_L=58.283
Time of run = 16.539111 min
Av. current (on 3x) = 29.262858 uA
Av. current (on 1x) = 29.175288 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 28.9520 | 29.0389 | 29.0840
up-down (mC)| -0.1429 | -0.0472 | -0.0081
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 56590.696 Hz | 1933874.5 /mC | 70.738 Hz | 56157589 | 800 | 1939679.1 /mC
2 | 84665.815 Hz | 2893285.9 /mC | 21.166 Hz | 84017840 | 4000 | 2901970.2 /mC
3 | 108880.07 Hz | 3720760.1 /mC | 181.467 Hz | 108046780 | 600 | 3731928.0 /mC
4 | 71614.091 Hz | 2447269.2 /mC | 17.904 Hz | 71066005 | 4000 | 2454614.7 /mC
5 | 947.87439 Hz | 32391.7 /mC | 947.874 Hz | 940620 | 1 | 32488.9 /mC
Trigger 5 corrected for pulser:
5 (phys) | 937.6975 Hz | 32043.9 /mC | 937.697 Hz | 930521.0 | 1 | 32140.1 /mC
8 | 1024.0 Hz | 34993.2 /mC | 0.016 Hz | 1016163 | 65535 | 35098.2 /mC
output 1012.610 Hz
Av. deadtime from accepted triggers = 0.1810
Av. deadtime from gated scalers = 0.1921
Accepted triggers = 1004860.00000
Rate of Left Arm Pulser for electronic DT = 10.176887
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.110378
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.0065353005
Right Arm Electronic DT = -1
Rate of Left Strobe = 311139.08
Rate of Right Arm Strobe = 154175.57
Signal | Charge (C)
upstream | 0.0288806
upstream 3x | 0.0290153
upstream 10x| 0.0290799
downstream | 0.0290235
downstream 3x | 0.0290625
downstream 10x| 0.0290880
****************************
End-of-run EPICS data for Run Number 2567 at Tue Mar 6 07:51:55 EST 2001
Right Arm D1 momentum : 1.433
Right Arm arm angle : 24.4724
Left Arm D1 momentum : 0.697398
Left Arm arm angle : 58.2825
Tiefenbach Hall A energy : 1722.67
Right Arm arm mispointing (HPT) : -1.98023
Left Arm arm mispointing (HPT) : 5.25852
Right Arm Q1 power supply current : 1077.51
Right Arm Q1 momentum : 1.43298
Right Arm Q1 gauss meter : -0.026863
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 616.764
Right Arm Q2 momentum : 1.43311
Right Arm Q2 gauss meter : 0.3241
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 492.383
Right Arm D1 momentum : 1.433
Right Arm D1 NMR : 0.531769
Right Arm Q3 power supply current : 570.297
Right Arm Q3 momentum : 1.43324
Right Arm Q3 gauss meter : 0.2556
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 524.44
Left Arm Q1 momentum : 0.697086
Left Arm Q1 gauss meter : 0.04498
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 300.287
Left Arm Q2 momentum : 0.69737
Left Arm Q2 gauss meter : -0.15884
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 232.036
Left Arm D1 momentum : 0.697399
Left Arm D1 NMR : 0.258274
Left Arm Q3 power supply current : 277.661
Left Arm Q3 momentum : 0.697432
Left Arm Q3 gauss meter : 0.13951
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 30.2686
Current on Unser monitor : 34.9675
Current on Upstream bcm : 30.4471
Current on Downstream bcm : 30.0902
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 30.8001
MBSY1c Hall A Beam energy : 1724.44
MBSY1c magnet current (amp) : 71.6882
MBSY1c Bdl : 430337
MBSY3c Hall C Beam energy : 3406.76
Tiefenbach Hall A energy : 1722.67
Tiefenbach Hall C energy : 3397.96
Delta(E)/E width (MV_AI_DXWID) : 7.06912
IPM1C12.XPOS : 0.00318235
IPM1H04A.XPOS : 1.8351
IPM1H04A.YPOS : 0.817271
IPM1H04B.XPOS : 0.0878363
IPM1H04B.YPOS : -0.038824
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -754
HacR_VPM_LVDT:VALr : 424
HacR_HPE1313A:0_Ch58 : -0.531738
HacR_HPE1313A:0_Ch55 :
HacR_HPE1313A:0_Ch54 : -0.803711
HacR_alignROLL : -0.323142
HacR_alignPITCH : -0.023461
HacR_alignHPT : -1.97859
HacL_HPM_LVDT:VALr : -8080
HacL_VPM_LVDT:VALr : -267
HacL_HPE1313A:0_Ch58 : -0.300293
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.345703
HacL_alignROLL : 0.0244208
HacL_alignPITCH : 0.0237132
HacL_alignHPT : 5.2581
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 68
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 17.66
haH2_P_Exhaust_R : 18.45
haH2_P_Fill_Bottle_R : 18.1
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 16.75
haD2_P_Fill_Bottle_R : 34.57
haD2_DP_Fill_Exhaust_R : 0.0763
haSC200_6_Sensor_1_R : 241.86
haSC200_6_Sensor_2_R : 224.27
haSC200_6_Sensor_3_R : 37.51
haSC200_6_Sensor_4_R : 40.79
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.95
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 88.04
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6.1
haITC502_4_Sensor_2_R : 100.7
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 5.93
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 266.4
haITC502_6_Sensor_1_R : 7.31
haITC502_6_Sensor_2_R : 5.88
haITC502_6_Sensor_3_R : 28.11
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
Wien angle : 45.4996
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1016.1
Wien field : 29.657
Laser attenuation Hall A : 199
Laser power Hall A : 57
Half-wave plate (off=out) : OFF