User name adev
Log entry time 18:06:55 on March 6, 2001
Entry number 57895
keyword=End_of_Run_2574
****************************
Run Number: 2574
End of Run Comment:
RunType=pion_prod,Tar=4He-10cm,Rad=out,comment=coin12,mode=coincidence,Lmom=2.195,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=31.982
Time of run = 21.782243 min
Av. current (on 3x) = 27.686925 uA
Av. current (on 1x) = 27.608344 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 36.0823 | 36.1850 | 36.2341
up-down (mC)| -0.1499 | -0.0328 | 0.0140
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 212.41308 Hz | 7672.0 /mC | 70.804 Hz | 277610 | 3 | 7693.8 /mC
2 | 15426.416 Hz | 557173.3 /mC | 15.426 Hz | 20161317 | 1000 | 558759.2 /mC
3 | 1165.8479 Hz | 42108.2 /mC | 97.154 Hz | 1523687 | 12 | 42228.1 /mC
4 | 16927.931 Hz | 611405.2 /mC | 16.928 Hz | 22123699 | 1000 | 613145.5 /mC
5 | 15.799566 Hz | 570.7 /mC | 15.800 Hz | 20649 | 1 | 572.3 /mC
Trigger 5 corrected for pulser:
5 (phys) | 5.625377 Hz | 203.2 /mC | 5.625 Hz | 7352.0004 | 1 | 203.8 /mC
8 | 1024.0 Hz | 36985.0 /mC | 0.016 Hz | 1338301 | 65535 | 37090.2 /mC
output 203.322 Hz
Av. deadtime from accepted triggers = 0.0297
Av. deadtime from gated scalers = 0.0450
Accepted triggers = 265728.00000
Rate of Left Arm Pulser for electronic DT = 10.174189
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.173424
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 7.5204933e-05
Right Arm Electronic DT = -1
Rate of Left Strobe = 29093.36
Rate of Right Arm Strobe = 15405.367
Signal | Charge (C)
upstream | 0.0360074
upstream 3x | 0.0361686
upstream 10x| 0.0362411
downstream | 0.0361573
downstream 3x | 0.0362014
downstream 10x| 0.0362271
****************************
End-of-run EPICS data for Run Number 2574 at Tue Mar 6 18:06:45 EST 2001
Right Arm D1 momentum : 1.866
Right Arm arm angle : 38.5544
Left Arm D1 momentum : 2.195
Left Arm arm angle : 31.9824
Tiefenbach Hall A energy : 3399.19
Right Arm arm mispointing (HPT) : 2.33888
Left Arm arm mispointing (HPT) : 4.08876
Right Arm Q1 power supply current : 1403.11
Right Arm Q1 momentum : 1.86601
Right Arm Q1 gauss meter : -0.03491
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 803.072
Right Arm Q2 momentum : 1.86601
Right Arm Q2 gauss meter : 0.422
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 646.086
Right Arm D1 momentum : 1.866
Right Arm D1 NMR : 0.69245
Right Arm Q3 power supply current : 742.523
Right Arm Q3 momentum : 1.86606
Right Arm Q3 gauss meter : 0.3329
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1651.41
Left Arm Q1 momentum : 2.19505
Left Arm Q1 gauss meter : 0.14023
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 945.189
Left Arm Q2 momentum : 2.19505
Left Arm Q2 gauss meter : -0.498
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 749.408
Left Arm D1 momentum : 2.195
Left Arm D1 NMR : 0.812183
Left Arm Q3 power supply current : 873.869
Left Arm Q3 momentum : 2.195
Left Arm Q3 gauss meter : 0.4363
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.148486
Current on Unser monitor : 5.17592
Current on Upstream bcm : 0.164503
Current on Downstream bcm : 0.135174
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
MBSY1c Bdl : 849671
MBSY3c Hall C Beam energy : 886.375
Tiefenbach Hall A energy : 3399.19
Tiefenbach Hall C energy : 884.981
Delta(E)/E width (MV_AI_DXWID) : 4.11081
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616895
HacR_HPM_LVDT:VALr : -4591
HacR_VPM_LVDT:VALr : 832
HacR_HPE1313A:0_Ch58 : -0.513672
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.885742
HacR_alignROLL : -0.405093
HacR_alignPITCH : -0.0403855
HacR_alignHPT : 2.33753
HacL_HPM_LVDT:VALr : -7062
HacL_VPM_LVDT:VALr : 705
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : -0.177246
HacL_alignROLL : 0.177044
HacL_alignPITCH : -0.0939509
HacL_alignHPT : 4.08547
haBDSPOS : 6.517e+06
haL1_Fan_frequency_R : 68
haL2_Fan_frequency_R : 0
haL3_Fan_frequency_R : 0
haH2_P_Fill_Target_R : 17.31
haH2_P_Exhaust_R : 18.17
haH2_P_Fill_Bottle_R : 17.83
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 16.43
haD2_P_Fill_Bottle_R : 33.98
haD2_DP_Fill_Exhaust_R : 0.0765
haSC200_6_Sensor_1_R : 241.56
haSC200_6_Sensor_2_R : 221.66
haSC200_6_Sensor_3_R : 37.41
haSC200_6_Sensor_4_R : 40.59
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 5.8
haITC502_1_Sensor_2_R : 5.8
haITC502_1_Sensor_3_R : 5.86
haITC502_2_Sensor_1_R : 94.98
haITC502_2_Sensor_2_R : 90.27
haITC502_2_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 6
haITC502_4_Sensor_2_R : 98.9
haITC502_4_Sensor_3_R : 65.3
haITC502_5_Sensor_1_R : 5.9
haITC502_5_Sensor_2_R : 5.81
haITC502_5_Sensor_3_R : 266.1
haITC502_6_Sensor_1_R : 12.21
haITC502_6_Sensor_2_R : 5.81
haITC502_6_Sensor_3_R : 28.1
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
Wien angle : 54.4574
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1225.6
Wien field : 35.677
Laser attenuation Hall A : 70
Laser power Hall A : 57
Half-wave plate (off=out) : ON