User name adev
Log entry time 23:40:23 on March 8, 2001
Entry number 58080
keyword=End_of_Run_2648
****************************
Run Number: 2648
End of Run Comment:
RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=coin12,mode=coincidence,Lmom=2.195,Rmom=-1.866,Ene=3.399,Angle_R=38.55,Angle_L=31.98
Time of run = 58.355875 min
Av. current (on 3x) = 29.670592 uA
Av. current (on 1x) = 29.57937 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 103.5678 | 103.8872 | 104.0336
up-down (mC)| -0.4966 | -0.1851 | -0.0149
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 690.40635 Hz | 23269.0 /mC | 115.068 Hz | 2417356 | 6 | 23340.8 /mC
2 | 66775.511 Hz | 2250562.1 /mC | 22.259 Hz | 233804600 | 3000 | 2257502.8 /mC
3 | 2521.0646 Hz | 84968.5 /mC | 105.044 Hz | 8827136 | 24 | 85230.5 /mC
4 | 75453.548 Hz | 2543041.6 /mC | 25.151 Hz | 264189470 | 3000 | 2550884.3 /mC
5 | 36.786642 Hz | 1239.8 /mC | 36.787 Hz | 128803 | 1 | 1243.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 26.608575 Hz | 896.8 /mC | 26.609 Hz | 93166.0 | 1 | 899.6 /mC
8 | 1024.0 Hz | 34512.3 /mC | 0.016 Hz | 3585385 | 65535 | 34618.7 /mC
output 285.390 Hz
Av. deadtime from accepted triggers = 0.0380
Av. deadtime from gated scalers = 0.0510
Accepted triggers = 999252.00000
Rate of Left Arm Pulser for electronic DT = 10.178067
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.176924
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.00011224289
Right Arm Electronic DT = -1
Rate of Left Strobe = 123406.36
Rate of Right Arm Strobe = 67893.391
Signal | Charge (C)
upstream | 0.1033195
upstream 3x | 0.1037947
upstream 10x| 0.1040262
downstream | 0.1038161
downstream 3x | 0.1039798
downstream 10x| 0.1040411
****************************
End-of-run EPICS data for Run Number 2648 at Thu Mar 8 23:40:11 EST 2001
Right Arm D1 momentum : 1.86601
Right Arm arm angle : 38.5541
Left Arm D1 momentum : 2.19499
Left Arm arm angle : 31.9804
Tiefenbach Hall A energy : 3399.2
Right Arm arm mispointing (HPT) : 2.37631
Left Arm arm mispointing (HPT) : 4.33411
Right Arm Q1 power supply current : 1403.29
Right Arm Q1 momentum : 1.86624
Right Arm Q1 gauss meter : -0.03497
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 803.128
Right Arm Q2 momentum : 1.86615
Right Arm Q2 gauss meter : 0.422
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 644.069
Right Arm D1 momentum : 1.86601
Right Arm D1 NMR : 0.692452
Right Arm Q3 power supply current : 742.324
Right Arm Q3 momentum : 1.86556
Right Arm Q3 gauss meter : 0.333
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1651.41
Left Arm Q1 momentum : 2.19505
Left Arm Q1 gauss meter : 0.1402
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 945.214
Left Arm Q2 momentum : 2.19511
Left Arm Q2 gauss meter : -0.498
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 749.517
Left Arm D1 momentum : 2.19499
Left Arm D1 NMR : 0.812181
Left Arm Q3 power supply current : 873.893
Left Arm Q3 momentum : 2.19506
Left Arm Q3 gauss meter : 0.4363
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.5395
Current on Unser monitor : 35.9791
Current on Upstream bcm : 29.5405
Current on Downstream bcm : 29.7211
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 29.7271
MBSY1c Hall A Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
MBSY1c Bdl : 849671
MBSY3c Hall C Beam energy : 886.375
Tiefenbach Hall A energy : 3399.2
Tiefenbach Hall C energy : 884.981
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00790828
IPM1H04A.XPOS : -0.0700522
IPM1H04A.YPOS : 0.616187
IPM1H04B.XPOS : -0.0243368
IPM1H04B.YPOS : 0.147061
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4626
HacR_VPM_LVDT:VALr : 786
HacR_HPE1313A:0_Ch58 : -0.509766
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.885742
HacR_alignROLL : -0.404924
HacR_alignPITCH : -0.0441778
HacR_alignHPT : 2.37517
HacL_HPM_LVDT:VALr : -7284
HacL_VPM_LVDT:VALr : 705
HacL_HPE1313A:0_Ch58 : -0.164551
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.17627
HacL_alignROLL : 0.178146
HacL_alignPITCH : -0.0976646
HacL_alignHPT : 4.33411
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 25.5
haL3_Fan_frequency_R : 37
haH2_P_Fill_Target_R : 19.34
haH2_P_Exhaust_R : 20.11
haH2_P_Fill_Bottle_R : 19.79
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 17.88
haD2_P_Fill_Bottle_R : 37.05
haD2_DP_Fill_Exhaust_R : 0.0743
haSC200_6_Sensor_1_R : 241.39
haSC200_6_Sensor_2_R : 28.44
haSC200_6_Sensor_3_R : 37.66
haSC200_6_Sensor_4_R : 40.58
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 87.34
haITC502_1_Sensor_2_R : 86.53
haITC502_1_Sensor_3_R : 82.09
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.03
haITC502_4_Sensor_1_R : 88.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22.1
haITC502_5_Sensor_1_R : 93.81
haITC502_5_Sensor_2_R : 85.37
haITC502_5_Sensor_3_R : 267.7
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 88.68
haITC502_6_Sensor_3_R : 28.43
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
Wien angle : 54.4574
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1225.6
Wien field : 35.677
Laser attenuation Hall A : 217
Laser power Hall A : 57
Half-wave plate (off=out) : ON