• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 14:37:15 on March 10, 2001

    Entry number 58260

    keyword=End_of_Run_2721
    ****************************
     Run Number: 2721
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=out,comment=sing18,mode=singles,Lmom=1.866,Rmom=-1.866,Ene=3.395,Angle_R=38.531,Angle_L=38.553
    
    Time of run = 6.9144857 min
    Av. current (on 3x) = 19.605941 uA
    Av. current (on 1x) = 19.541825 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    8.1073  |    8.1339  |    8.1477
    up-down    (mC)|   -0.0362  |   -0.0237  |   -0.0064
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 395.04505 Hz  |     20149.3 /mC  |  395.045 Hz  |    163892  |     1   |     20215.4 /mC
        2      | 41998.889 Hz  |   2142151.1 /mC  |   41.999 Hz  |  17424043  |  1000   |   2149179.5 /mC
        3      | 1501.9073 Hz  |     76604.7 /mC  | 1501.907 Hz  |    623095  |     1   |     76856.0 /mC
        4      | 43724.125 Hz  |   2230146.7 /mC  |   43.724 Hz  |  18139790  |  1000   |   2237463.8 /mC
        5      | 11.432521 Hz  |       583.1 /mC  |   11.433 Hz  |      4743  |     1   |       585.0 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 1.260639 Hz  |        64.3 /mC  |    1.261 Hz  | 523.00006  |     1   |        64.5 /mC
        8    | 1024.0 Hz  |     52229.1 /mC  |    0.016 Hz  |    424826  | 65535   |     52400.4 /mC
        output                      1459.222 Hz
    Av. deadtime from accepted triggers = 0.2598
    Av. deadtime from gated scalers = 0.2559
    Accepted triggers  = 605386.00000
    Rate of Left Arm Pulser for electronic DT  = 10.171882
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.171882
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 71789.505
    Rate of Right Arm Strobe  = 42248.095
        Signal     |    Charge   (C)   
       upstream    |    0.0080892     
       upstream 3x |    0.0081220     
       upstream 10x|    0.0081445     
      downstream   |    0.0081254   
     downstream 3x |    0.0081457   
     downstream 10x|    0.0081509    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2721 at Sat Mar 10 14:37:01 EST 2001
    Right Arm D1 momentum                    : 1.866
    Right Arm arm angle                      : 38.5533
    Left Arm D1 momentum                      : 1.866
    Left Arm arm angle                        : 38.5314
    Tiefenbach Hall A energy                : 3399.18
    Right Arm arm mispointing (HPT)          : 2.58241
    Left Arm arm mispointing (HPT)            : 5.69546
    Right Arm Q1 power supply current        : 1403.08
    Right Arm Q1 momentum                    : 1.86596
    Right Arm Q1 gauss meter                 : -0.03491
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 802.856
    Right Arm Q2 momentum                    : 1.86551
    Right Arm Q2 gauss meter                 : 0.4219
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 646.02
    Right Arm D1 momentum                    : 1.866
    Right Arm D1 NMR                         : 0.69245
    Right Arm Q3 power supply current        : 742.532
    Right Arm Q3 momentum                    : 1.86609
    Right Arm Q3 gauss meter                 : 0.333
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1403.74
    Left Arm Q1 momentum                      : 1.86586
    Left Arm Q1 gauss meter                   : 0.11932
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 803.538
    Left Arm Q2 momentum                      : 1.86609
    Left Arm Q2 gauss meter                   : -0.4235
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 630.942
    Left Arm D1 momentum                      : 1.866
    Left Arm D1 NMR                           : 0.690515
    Left Arm Q3 power supply current          : 742.781
    Left Arm Q3 momentum                      : 1.86573
    Left Arm Q3 gauss meter                   : 0.3709
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 19.6354
    Current on Unser monitor                : 26.8207
    Current on Upstream bcm                 : 19.6163
    Current on Downstream bcm               : 19.6618
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 19.8222
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.18
    Tiefenbach Hall C energy                : 883.935
    Delta(E)/E width (MV_AI_DXWID)          : 2.56589
    IPM1C12.XPOS                            : 0.00799745
    IPM1H04A.XPOS                           : 0.423876
    IPM1H04A.YPOS                           : 0.431227
    IPM1H04B.XPOS                           : 0.000486295
    IPM1H04B.YPOS                           : -0.0369037
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4816
     HacR_VPM_LVDT:VALr                     : 813
     HacR_HPE1313A:0_Ch58                   : -0.51123
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.87793
     HacR_alignROLL                         : -0.397036
     HacR_alignPITCH                        : -0.0423822
     HacR_alignHPT                          : 2.58269
     HacL_HPM_LVDT:VALr                     : -8484
     HacL_VPM_LVDT:VALr                     : 458
     HacL_HPE1313A:0_Ch58                   : -0.172852
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.25293
     HacL_alignROLL                         : 0.108935
     HacL_alignPITCH                        : -0.089516
     HacL_alignHPT                          : 5.6977
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 63.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 20.44
    haH2_P_Exhaust_R                         : 20.96
    haH2_P_Fill_Bottle_R                     : 20.98
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.69
    haD2_P_Fill_Bottle_R                     : 38.73
    haD2_DP_Fill_Exhaust_R                   : 0.0741
    haSC200_6_Sensor_1_R                     : 241.71
    haSC200_6_Sensor_2_R                     : 27.34
    haSC200_6_Sensor_3_R                     : 38.17
    haSC200_6_Sensor_4_R                     : 40.78
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 82.62
    haITC502_1_Sensor_2_R                    : 81.91
    haITC502_1_Sensor_3_R                    : 75.67
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 83.4
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 90.02
    haITC502_5_Sensor_2_R                    : 81.38
    haITC502_5_Sensor_3_R                    : 267.1
    haITC502_6_Sensor_1_R                    : 96.71
    haITC502_6_Sensor_2_R                    : 80.42
    haITC502_6_Sensor_3_R                    : 28.34
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 160
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON