User name adev
Log entry time 23:53:40 on March 11, 2001
Entry number 58468
keyword=End_of_Run_2811
****************************
Run Number: 2811
End of Run Comment:
RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
Time of run = 18.29904 min
Av. current (on 3x) = 22.374125 uA
Av. current (on 1x) = 22.302172 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 24.4865 | 24.5655 | 24.6037
up-down (mC)| -0.0914 | -0.0454 | 0.0052
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 24862.985 Hz | 1111238.3 /mC | 69.064 Hz | 27298125 | 360 | 1114823.5 /mC
2 | 71001.964 Hz | 3173396.3 /mC | 49.307 Hz | 77956067 | 1440 | 3183634.5 /mC
3 | 10052.708 Hz | 449300.6 /mC | 167.545 Hz | 11037294 | 60 | 450750.2 /mC
4 | 45652.738 Hz | 2040425.7 /mC | 63.407 Hz | 50124077 | 720 | 2047008.6 /mC
5 | 775.26562 Hz | 34650.1 /mC | 775.266 Hz | 851197 | 1 | 34761.9 /mC
Trigger 5 corrected for pulser:
5 (phys) | 765.0884 Hz | 34195.2 /mC | 765.088 Hz | 840023.0 | 1 | 34305.6 /mC
8 | 1024.0 Hz | 45767.2 /mC | 0.016 Hz | 1124293 | 65535 | 45914.8 /mC
output 912.592 Hz
Av. deadtime from accepted triggers = 0.1775
Av. deadtime from gated scalers = 0.1819
Accepted triggers = 1001973.00000
Rate of Left Arm Pulser for electronic DT = 10.177219
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.171754
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.0005369608
Right Arm Electronic DT = -1
Rate of Left Strobe = 88431.257
Rate of Right Arm Strobe = 98287.893
Signal | Charge (C)
upstream | 0.0244408
upstream 3x | 0.0245428
upstream 10x| 0.0246063
downstream | 0.0245322
downstream 3x | 0.0245882
downstream 10x| 0.0246011
****************************
End-of-run EPICS data for Run Number 2811 at Sun Mar 11 23:53:26 EST 2001
Right Arm D1 momentum : 2.799
Right Arm arm angle : 18.5811
Left Arm D1 momentum : 1.11301
Left Arm arm angle : 53.1719
Tiefenbach Hall A energy : 3399.17
Right Arm arm mispointing (HPT) : -1.61144
Left Arm arm mispointing (HPT) : 5.41991
Right Arm Q1 power supply current : 2104.66
Right Arm Q1 momentum : 2.79899
Right Arm Q1 gauss meter : -0.05229
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1204.57
Right Arm Q2 momentum : 2.79893
Right Arm Q2 gauss meter : 0.6324
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 997.406
Right Arm D1 momentum : 2.799
Right Arm D1 NMR : 1.03867
Right Arm Q3 power supply current : 1113.56
Right Arm Q3 momentum : 2.79854
Right Arm Q3 gauss meter : 0.4995
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 837.06
Left Arm Q1 momentum : 1.11276
Left Arm Q1 gauss meter : 0.07158
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 479.516
Left Arm Q2 momentum : 1.1136
Left Arm Q2 gauss meter : -0.2529
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 371.548
Left Arm D1 momentum : 1.113
Left Arm D1 NMR : 0.412048
Left Arm Q3 power supply current : 443.038
Left Arm Q3 momentum : 1.11283
Left Arm Q3 gauss meter : 0.2212
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 24.1772
Current on Unser monitor : 31.7357
Current on Upstream bcm : 24.1888
Current on Downstream bcm : 24.1656
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 24.3754
MBSY1c Hall A Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
MBSY1c Bdl : 849671
MBSY3c Hall C Beam energy : 885.574
Tiefenbach Hall A energy : 3399.17
Tiefenbach Hall C energy : 884.441
Delta(E)/E width (MV_AI_DXWID) : 1.17947
IPM1C12.XPOS : -0.00700577
IPM1H04A.XPOS : -0.123248
IPM1H04A.YPOS : 0.478456
IPM1H04B.XPOS : 0.00362723
IPM1H04B.YPOS : -0.0283282
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1048
HacR_VPM_LVDT:VALr : 119
HacR_HPE1313A:0_Ch58 : -0.522461
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.825195
HacR_alignROLL : -0.344834
HacR_alignPITCH : -0.0324391
HacR_alignHPT : -1.61173
HacL_HPM_LVDT:VALr : -8185
HacL_VPM_LVDT:VALr : -585
HacL_HPE1313A:0_Ch58 : -0.297852
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.391113
HacL_alignROLL : -0.0157774
HacL_alignPITCH : 0.0210936
HacL_alignHPT : 5.42012
haBDSPOS : 3.10127e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 27
haL3_Fan_frequency_R : 37
haH2_P_Fill_Target_R : 19.58
haH2_P_Exhaust_R : 20.32
haH2_P_Fill_Bottle_R : 20.11
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -800
haD2_P_Exhaust_R : 18
haD2_P_Fill_Bottle_R : 37.25
haD2_DP_Fill_Exhaust_R : 0.0744
haSC200_6_Sensor_1_R : 241.29
haSC200_6_Sensor_2_R : 27.32
haSC200_6_Sensor_3_R : 38.05
haSC200_6_Sensor_4_R : 40.69
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.78
haITC502_1_Sensor_2_R : 83.07
haITC502_1_Sensor_3_R : 76.7
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.03
haITC502_4_Sensor_1_R : 84.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 22
haITC502_5_Sensor_1_R : 91.15
haITC502_5_Sensor_2_R : 82.42
haITC502_5_Sensor_3_R : 266.6
haITC502_6_Sensor_1_R : 98.45
haITC502_6_Sensor_2_R : 82.22
haITC502_6_Sensor_3_R : 28.36
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 186
Laser power Hall A : 57
Half-wave plate (off=out) : ON