• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 00:34:28 on March 12, 2001

    Entry number 58479

    keyword=End_of_Run_2815
    ****************************
     Run Number: 2815
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=3,comment=coin10,mode=coincidence,Lmom=1.1130,Rmom=-2.799,Ene=3.399,Angle_R=18.582,Angle_L=53.172
    
    Time of run = 8.6743978 min
    Av. current (on 3x) = 24.225505 uA
    Av. current (on 1x) = 24.148266 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   12.5683  |   12.6085  |   12.6275
    up-down    (mC)|   -0.0617  |   -0.0330  |   -0.0088
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 28206.715 Hz  |   1164339.6 /mC  |   78.352 Hz  |  14680576  |   360   |   1168063.8 /mC
        2      | 52606.766 Hz  |   2171544.7 /mC  |   36.532 Hz  |  27379921  |  1440   |   2178490.4 /mC
        3      | 8103.3809 Hz  |    334497.9 /mC  |  135.056 Hz  |   4217517  |    60   |    335567.8 /mC
        4      | 31607.973 Hz  |   1304739.5 /mC  |   43.900 Hz  |  16450808  |   720   |   1308912.7 /mC
        5      | 903.45176 Hz  |     37293.4 /mC  |  903.452 Hz  |    470214  |     1   |     37412.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 893.26085 Hz  |     36872.7 /mC  |  893.261 Hz  | 464910.0  |     1   |     36990.7 /mC
        8    | 1024.0 Hz  |     42269.5 /mC  |    0.016 Hz  |    532955  | 65535   |     42404.7 /mC
        output                       966.828 Hz
    Av. deadtime from accepted triggers = 0.1805
    Av. deadtime from gated scalers = 0.1822
    Accepted triggers  = 503199.00000
    Rate of Left Arm Pulser for electronic DT  = 10.190909
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.183224
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00075414781
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 62851.819
    Rate of Right Arm Strobe  = 85467.714
        Signal     |    Charge   (C)   
       upstream    |    0.0125374     
       upstream 3x |    0.0125920     
       upstream 10x|    0.0126231     
      downstream   |    0.0125991   
     downstream 3x |    0.0126250   
     downstream 10x|    0.0126319    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2815 at Mon Mar 12 00:34:14 EST 2001
    Right Arm D1 momentum                    : 2.799
    Right Arm arm angle                      : 18.5811
    Left Arm D1 momentum                      : 1.113
    Left Arm arm angle                        : 53.1719
    Tiefenbach Hall A energy                : 3399.16
    Right Arm arm mispointing (HPT)          : -1.60396
    Left Arm arm mispointing (HPT)            : 5.42144
    Right Arm Q1 power supply current        : 2104.62
    Right Arm Q1 momentum                    : 2.79894
    Right Arm Q1 gauss meter                 : -0.0523
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1204.52
    Right Arm Q2 momentum                    : 2.79883
    Right Arm Q2 gauss meter                 : 0.6324
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 997.402
    Right Arm D1 momentum                    : 2.799
    Right Arm D1 NMR                         : 1.03867
    Right Arm Q3 power supply current        : 1113.6
    Right Arm Q3 momentum                    : 2.79863
    Right Arm Q3 gauss meter                 : 0.4995
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 837.13
    Left Arm Q1 momentum                      : 1.11271
    Left Arm Q1 gauss meter                   : 0.07157
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 479.428
    Left Arm Q2 momentum                      : 1.1134
    Left Arm Q2 gauss meter                   : -0.2529
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 371.546
    Left Arm D1 momentum                      : 1.113
    Left Arm D1 NMR                           : 0.412048
    Left Arm Q3 power supply current          : 443.087
    Left Arm Q3 momentum                      : 1.11295
    Left Arm Q3 gauss meter                   : 0.2213
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 24.3256
    Current on Unser monitor                : 29.5159
    Current on Upstream bcm                 : 24.3872
    Current on Downstream bcm               : 24.264
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 24.5755
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.16
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.16493
    IPM1C12.XPOS                            : 0.00641009
    IPM1H04A.XPOS                           : -0.146588
    IPM1H04A.YPOS                           : 0.642798
    IPM1H04B.XPOS                           : -0.0206738
    IPM1H04B.YPOS                           : -0.0606614
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -1056
     HacR_VPM_LVDT:VALr                     : 118
     HacR_HPE1313A:0_Ch58                   : -0.522949
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.824707
     HacR_alignROLL                         : -0.344225
     HacR_alignPITCH                        : -0.0330217
     HacR_alignHPT                          : -1.60424
     HacL_HPM_LVDT:VALr                     : -8187
     HacL_VPM_LVDT:VALr                     : -579
     HacL_HPE1313A:0_Ch58                   : -0.294922
     HacL_HPE1313A:0_Ch55                   : 23.584
     HacL_HPE1313A:0_Ch54                   : -0.38916
     HacL_alignROLL                         : -0.014316
     HacL_alignPITCH                        : 0.0200787
     HacL_alignHPT                          : 5.42277
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 25.5
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 19.52
    haH2_P_Exhaust_R                         : 20.26
    haH2_P_Fill_Bottle_R                     : 20.08
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -600
    haD2_P_Exhaust_R                         : 17.95
    haD2_P_Fill_Bottle_R                     : 37.19
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.64
    haSC200_6_Sensor_2_R                     : 27.57
    haSC200_6_Sensor_3_R                     : 38.34
    haSC200_6_Sensor_4_R                     : 40.86
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.81
    haITC502_1_Sensor_2_R                    : 83.1
    haITC502_1_Sensor_3_R                    : 77.23
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.03
    haITC502_4_Sensor_1_R                    : 84.8
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 91.06
    haITC502_5_Sensor_2_R                    : 82.38
    haITC502_5_Sensor_3_R                    : 266.7
    haITC502_6_Sensor_1_R                    : 98.43
    haITC502_6_Sensor_2_R                    : 82.27
    haITC502_6_Sensor_3_R                    : 28.34
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 186
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON