    User name adev

    Log entry time 12:20:22 on March 12, 2001

    Entry number 58547

    keyword=End_of_Run_2846
    ****************************
     Run Number: 2846
    End of Run Comment:
    RunType=pion_prod,Tar=LD2-15cm,Rad=6,comment=coin22,mode=coincidence,Lmom=2.4660,Rmom=-1.6138,Ene=3.399,Angle_R=45.240,Angle_L=27.649
    
    
    Time of run = 58.39253 min
    Av. current (on 3x) = 28.229239 uA
    Av. current (on 1x) = 28.141499 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|   98.5952  |   98.9026  |   99.0371
    up-down    (mC)|   -0.4899  |   -0.2197  |   -0.0419
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 541.98285 Hz  |     19199.3 /mC  |  108.397 Hz  |   1898865  |     5   |     19259.2 /mC
        2      | 57149.035 Hz  |   2024462.5 /mC  |   28.575 Hz  | 200224600  |  2000   |   2030774.3 /mC
        3      | 2473.0024 Hz  |     87604.3 /mC  |   98.920 Hz  |   8664292  |    25   |     87877.4 /mC
        4      | 74619.403 Hz  |   2643337.4 /mC  |   37.310 Hz  | 261432940  |  2000   |   2651578.8 /mC
        5      | 31.286251 Hz  |      1108.3 /mC  |   31.286 Hz  |    109613  |     1   |      1111.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 21.105725 Hz  |       747.7 /mC  |   21.106 Hz  | 73945.0  |     1   |       750.0 /mC
        8    | 1024.0 Hz  |     36274.4 /mC  |    0.016 Hz  |   3587637  | 65535   |     36387.5 /mC
        output                       285.320 Hz
    Av. deadtime from accepted triggers = 0.0393
    Av. deadtime from gated scalers = 0.0518
    Accepted triggers  = 999634.00000
    Rate of Left Arm Pulser for electronic DT  = 10.180526
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.178813
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.00016821801
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 120518.97
    Rate of Right Arm Strobe  = 58935.763
        Signal     |    Charge   (C)   
       upstream    |    0.0983502     
       upstream 3x |    0.0987928     
       upstream 10x|    0.0990162     
      downstream   |    0.0988401   
     downstream 3x |    0.0990125   
     downstream 10x|    0.0990581    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2846 at Mon Mar 12 12:20:05 EST 2001
    Right Arm D1 momentum                    : 1.6138
    Right Arm arm angle                      : 45.2401
    Left Arm D1 momentum                      : 2.466
    Left Arm arm angle                        : 27.6493
    Tiefenbach Hall A energy                : 3399.17
    Right Arm arm mispointing (HPT)          : -1.17737
    Left Arm arm mispointing (HPT)            : 5.68669
    Right Arm Q1 power supply current        : 1213.59
    Right Arm Q1 momentum                    : 1.61396
    Right Arm Q1 gauss meter                 : -0.03024
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 694.653
    Right Arm Q2 momentum                    : 1.61409
    Right Arm Q2 gauss meter                 : 0.365
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 554.966
    Right Arm D1 momentum                    : 1.6138
    Right Arm D1 NMR                         : 0.598862
    Right Arm Q3 power supply current        : 642.083
    Right Arm Q3 momentum                    : 1.61364
    Right Arm Q3 gauss meter                 : 0.288
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1855.31
    Left Arm Q1 momentum                      : 2.46609
    Left Arm Q1 gauss meter                   : 0.15752
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 
    Left Arm Q2 momentum                      : 2.46608
    Left Arm Q2 gauss meter                   : -0.5593
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 848.583
    Left Arm D1 momentum                      : 2.466
    Left Arm D1 NMR                           : 0.912691
    Left Arm Q3 power supply current          : 981.743
    Left Arm Q3 momentum                      : 2.46596
    Left Arm Q3 gauss meter                   : 0.4901
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 29.0428
    Current on Unser monitor                : 36.9348
    Current on Upstream bcm                 : 29.1117
    Current on Downstream bcm               : 28.9739
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 29.2316
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.17
    Tiefenbach Hall C energy                : 884.441
    Delta(E)/E width (MV_AI_DXWID)          : 1.18639
    IPM1C12.XPOS                            : -0.00771028
    IPM1H04A.XPOS                           : -0.178502
    IPM1H04A.YPOS                           : 0.464334
    IPM1H04B.XPOS                           : -0.117416
    IPM1H04B.YPOS                           : -0.0325604
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616943
     HacR_HPM_LVDT:VALr                     : -1466
     HacR_VPM_LVDT:VALr                     : 632
     HacR_HPE1313A:0_Ch58                   : -0.524902
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.903809
     HacR_alignROLL                         : -0.423602
     HacR_alignPITCH                        : -0.0294302
     HacR_alignHPT                          : -1.17513
     HacL_HPM_LVDT:VALr                     : -8491
     HacL_VPM_LVDT:VALr                     : 1241
     HacL_HPE1313A:0_Ch58                   : -0.149902
     HacL_HPE1313A:0_Ch55                   : 23.6328
     HacL_HPE1313A:0_Ch54                   : -0.216797
     HacL_alignROLL                         : 0.141625
     HacL_alignPITCH                        : -0.110911
     HacL_alignHPT                          : 5.68647
    haBDSPOS                                 : 3.10127e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 64
    haL3_Fan_frequency_R                     : 37
    haH2_P_Fill_Target_R                     : 20.43
    haH2_P_Exhaust_R                         : 20.94
    haH2_P_Fill_Bottle_R                     : 21.05
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -360
    haD2_P_Exhaust_R                         : 18.76
    haD2_P_Fill_Bottle_R                     : 38.79
    haD2_DP_Fill_Exhaust_R                   : 0.0744
    haSC200_6_Sensor_1_R                     : 241.58
    haSC200_6_Sensor_2_R                     : 27.4
    haSC200_6_Sensor_3_R                     : 38.3
    haSC200_6_Sensor_4_R                     : 40.86
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.7
    haITC502_1_Sensor_2_R                    : 83.02
    haITC502_1_Sensor_3_R                    : 76.88
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.01
    haITC502_4_Sensor_1_R                    : 84.3
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 22
    haITC502_5_Sensor_1_R                    : 91.19
    haITC502_5_Sensor_2_R                    : 82.48
    haITC502_5_Sensor_3_R                    : 266.8
    haITC502_6_Sensor_1_R                    : 98.07
    haITC502_6_Sensor_2_R                    : 81.67
    haITC502_6_Sensor_3_R                    : 28.33
    Right Arm Arm Collimator                 : 0.615088
    Left Arm Arm Collimator                   : 0.616943
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 204
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : ON