User name adev
Log entry time 20:23:24 on March 12, 2001
Entry number 58608
keyword=Start_Run_2867_RunType=Optics,Tar=carbon,Rad=out,comment=kinematics17,mode=singles,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
Beginning-of-run EPICS data for Run Number 2867 at Mon Mar 12 20:23:14 EST 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=20,ps3=10,ps4=10,ps5=1,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 636.055
Right Arm Q1 momentum : 0.845891
Right Arm Q1 gauss meter : -0.015932
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 364.011
Right Arm Q2 momentum : 0.845815
Right Arm Q2 gauss meter : 0.19144
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 288.528
Right Arm D1 momentum : 0.846002
Right Arm D1 NMR : 0.313941
Right Arm Q3 power supply current : 336.704
Right Arm Q3 momentum : 0.846185
Right Arm Q3 gauss meter : 0.15087
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.11
Left Arm Q1 momentum : 1.98598
Left Arm Q1 gauss meter : 0.12695
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.008
Left Arm Q2 momentum : 1.98562
Left Arm Q2 gauss meter : -0.4506
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 673.715
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734892
Left Arm Q3 power supply current : 790.518
Left Arm Q3 momentum : 1.98564
Left Arm Q3 gauss meter : 0.3949
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 5.18401
Current on Unser monitor : 12.4424
Current on Upstream bcm : 5.2105
Current on Downstream bcm : 5.08043
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 5.14697
Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.168498
haBDSPOS : 708449
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 66
haL3_Fan_frequency_R : 25
haSC200_6_Sensor_1_R : 241.14
haSC200_6_Sensor_2_R : 27.24
haSC200_6_Sensor_3_R : 38.2
haSC200_6_Sensor_4_R : 40.73
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.53
haITC502_1_Sensor_2_R : 82.84
haITC502_1_Sensor_3_R : 76.54
haITC502_4_Sensor_1_R : 84.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 91.09
haITC502_5_Sensor_2_R : 82.3
haITC502_5_Sensor_3_R : 269.8
haITC502_6_Sensor_1_R : 97.95
haITC502_6_Sensor_2_R : 81.53
haITC502_6_Sensor_3_R : 28.58
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1797
HacR_VPM_LVDT:VALr : 581
HacR_HPE1313A:0_Ch58 : -0.522461
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.886719
HacR_alignROLL : -0.406952
HacR_alignPITCH : -0.0315413
HacR_alignHPT : -0.814107
HacL_HPM_LVDT:VALr : -7066
HacL_VPM_LVDT:VALr : 1641
HacL_HPE1313A:0_Ch58 : -0.234863
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.104492
HacL_alignROLL : 0.441004
HacL_alignPITCH : -0.055342
HacL_alignHPT : 3.95054
Right Arm Angle Floor Angle : 48
Right Arm Angle Vernier : -36
Right Arm Scattering Angle : 47.995
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4729
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 256
Laser power Hall A : 57
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88