User name adev
Log entry time 23:23:59 on March 13, 2001
Entry number 58720
keyword=End_of_Run_2903
****************************
Run Number: 2903
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics17,mode=coincidence,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
Time of run = 66.435563 min
Av. current (on 3x) = 31.627915 uA
Av. current (on 1x) = 31.54006 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 125.7229 | 126.0731 | 125.9159
up-down (mC)| -0.6462 | -0.1829 | -0.1667
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 3145.4765 Hz | 99452.5 /mC | 3.495 Hz | 12538290 | 900 | 99729.6 /mC
2 | 13621.976 Hz | 430694.7 /mC | 3.892 Hz | 54299020 | 3500 | 431894.4 /mC
3 | 134029.93 Hz | 4237710.0 /mC | 3.808 Hz | 534261240 | 35200 | 4249514.1 /mC
4 | 40748.02 Hz | 1288356.2 /mC | 38.808 Hz | 162427060 | 1050 | 1291944.9 /mC
5 | 55.946692 Hz | 1768.9 /mC | 55.947 Hz | 223011 | 1 | 1773.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 45.767656 Hz | 1447.1 /mC | 45.768 Hz | 182436.0 | 1 | 1451.1 /mC
8 | 1024.0 Hz | 32376.5 /mC | 85.333 Hz | 4081801 | 12 | 32466.6 /mC
output 188.103 Hz
Av. deadtime from accepted triggers = 0.0163
Av. deadtime from gated scalers = 0.0293
Accepted triggers = 749805.00000
Rate of Left Arm Pulser for electronic DT = 10.179036
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.106535
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.0071226124
Right Arm Electronic DT = -1
Rate of Left Strobe = 256173.17
Rate of Right Arm Strobe = 17358.489
Signal | Charge (C)
upstream | 0.1253998
upstream 3x | 0.1259817
upstream 10x| 0.1258326
downstream | 0.1260460
downstream 3x | 0.1261646
downstream 10x| 0.1259993
****************************
End-of-run EPICS data for Run Number 2903 at Tue Mar 13 23:23:48 EST 2001
Right Arm D1 momentum : 0.846
Right Arm arm angle : 47.9952
Left Arm D1 momentum : 1.986
Left Arm arm angle : 12.473
Tiefenbach Hall A energy : 3399.2
Right Arm arm mispointing (HPT) : -0.844828
Left Arm arm mispointing (HPT) : 3.94071
Right Arm Q1 power supply current : 635.985
Right Arm Q1 momentum : 0.845798
Right Arm Q1 gauss meter : -0.015935
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 364.21
Right Arm Q2 momentum : 0.846277
Right Arm Q2 gauss meter : 0.19148
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 288.528
Right Arm D1 momentum : 0.846
Right Arm D1 NMR : 0.313941
Right Arm Q3 power supply current : 336.569
Right Arm Q3 momentum : 0.845846
Right Arm Q3 gauss meter : 0.15089
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.19
Left Arm Q1 momentum : 1.98607
Left Arm Q1 gauss meter : 0.12697
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.222
Left Arm Q2 momentum : 1.98612
Left Arm Q2 gauss meter : -0.4507
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 673.706
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734893
Left Arm Q3 power supply current : 790.561
Left Arm Q3 momentum : 1.98574
Left Arm Q3 gauss meter : 0.3948
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 67.2803
Current on Unser monitor : 73.0863
Current on Upstream bcm : 67.3789
Current on Downstream bcm : 67.1817
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 67.8324
MBSY1c Hall A Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
MBSY1c Bdl : 849671
MBSY3c Hall C Beam energy : 885.574
Tiefenbach Hall A energy : 3399.2
Tiefenbach Hall C energy : 884.441
Delta(E)/E width (MV_AI_DXWID) : 1.17531
IPM1C12.XPOS : 0.00362554
IPM1H04A.XPOS : 1.75827
IPM1H04A.YPOS : 0.557169
IPM1H04B.XPOS : 0.0230721
IPM1H04B.YPOS : 0.0170272
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1770
HacR_VPM_LVDT:VALr : 511
HacR_HPE1313A:0_Ch58 : -0.520996
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.886719
HacR_alignROLL : -0.405966
HacR_alignPITCH : -0.0333369
HacR_alignHPT : -0.846011
HacL_HPM_LVDT:VALr : -7057
HacL_VPM_LVDT:VALr : 1683
HacL_HPE1313A:0_Ch58 : -0.227051
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : 0.104004
HacL_alignROLL : 0.44046
HacL_alignPITCH : -0.0626917
HacL_alignHPT : 3.94075
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 71
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 20.12
haH2_P_Exhaust_R : 20.51
haH2_P_Fill_Bottle_R : 20.65
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.6
haD2_P_Fill_Bottle_R : 38.55
haD2_DP_Fill_Exhaust_R : 0.074
haSC200_6_Sensor_1_R : 241.61
haSC200_6_Sensor_2_R : 27.54
haSC200_6_Sensor_3_R : 38.5
haSC200_6_Sensor_4_R : 40.99
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 83.21
haITC502_1_Sensor_2_R : 82.48
haITC502_1_Sensor_3_R : 78.56
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.19
haITC502_4_Sensor_1_R : 86.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 89.34
haITC502_5_Sensor_2_R : 81.48
haITC502_5_Sensor_3_R : 264.6
haITC502_6_Sensor_1_R : 99.56
haITC502_6_Sensor_2_R : 84
haITC502_6_Sensor_3_R : 27.88
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 349
Laser power Hall A : 57
Half-wave plate (off=out) : ON