Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 05:11:20 on March 14, 2001
Entry number 58740
keyword=End_of_Run_2910
****************************
Run Number: 2910
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics17,mode=coincidence,Lmom=1.98600,Rmom=-0.84600,Ene=3.399,Angle_R=47.995,Angle_L=12.473
Time of run = 41.711492 min
Av. current (on 3x) = 72.675656 uA
Av. current (on 1x) = 72.506877 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 181.4622 | 181.8846 | 166.3700
up-down (mC)| -1.0037 | -0.0416 | -3.2197
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 6903.4253 Hz | 94989.5 /mC | 7.670 Hz | 17277130 | 900 | 95210.6 /mC
2 | 30097.721 Hz | 414137.6 /mC | 8.599 Hz | 75325250 | 3500 | 415101.6 /mC
3 | 289566.08 Hz | 3984361.5 /mC | 8.226 Hz | 724693990 | 35200 | 3993636.1 /mC
4 | 87609.253 Hz | 1205482.8 /mC | 9.222 Hz | 219258760 | 9500 | 1208288.9 /mC
5 | 190.60095 Hz | 2622.6 /mC | 190.601 Hz | 477015 | 1 | 2628.7 /mC
Trigger 5 corrected for pulser:
5 (phys) | 180.4235 Hz | 2482.6 /mC | 180.423 Hz | 451544.0 | 1 | 2488.4 /mC
8 | 1024.0 Hz | 14090.0 /mC | 85.333 Hz | 2562754 | 12 | 14122.8 /mC
output 300.160 Hz
Av. deadtime from accepted triggers = 0.0300
Av. deadtime from gated scalers = 0.0452
Accepted triggers = 751207.00000
Rate of Left Arm Pulser for electronic DT = 10.177451
Rate of Right Arm Pulser for electronic DT = 0.0
Rate of Left Arm Pulser&trig for electronic DT = 10.026014
Rate of Right Arm Pulser&trig for electronic DT = 0.0
Left Arm Electronic DT = 0.014879667
Right Arm Electronic DT = -1
Rate of Left Strobe = 543002.7
Rate of Right Arm Strobe = 38299.672
Signal | Charge (C)
upstream | 0.1809603
upstream 3x | 0.1818638
upstream 10x| 0.1647602
downstream | 0.1819640
downstream 3x | 0.1819054
downstream 10x| 0.1679799
****************************
End-of-run EPICS data for Run Number 2910 at Wed Mar 14 05:11:09 EST 2001
Right Arm D1 momentum : 0.846
Right Arm arm angle : 47.9952
Left Arm D1 momentum : 1.986
Left Arm arm angle : 12.473
Tiefenbach Hall A energy : 3399.18
Right Arm arm mispointing (HPT) : -0.845666
Left Arm arm mispointing (HPT) : 3.94276
Right Arm Q1 power supply current : 636.09
Right Arm Q1 momentum : 0.845938
Right Arm Q1 gauss meter : -0.015947
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 363.976
Right Arm Q2 momentum : 0.845734
Right Arm Q2 gauss meter : 0.19138
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 288.528
Right Arm D1 momentum : 0.845999
Right Arm D1 NMR : 0.31394
Right Arm Q3 power supply current : 336.558
Right Arm Q3 momentum : 0.845817
Right Arm Q3 gauss meter : 0.15092
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1494.11
Left Arm Q1 momentum : 1.98598
Left Arm Q1 gauss meter : 0.12697
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 855.025
Left Arm Q2 momentum : 1.98566
Left Arm Q2 gauss meter : -0.4506
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 673.708
Left Arm D1 momentum : 1.986
Left Arm D1 NMR : 0.734892
Left Arm Q3 power supply current : 790.666
Left Arm Q3 momentum : 1.986
Left Arm Q3 gauss meter : 0.3948
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 81.1657
Current on Unser monitor : 86.3145
Current on Upstream bcm : 81.2278
Current on Downstream bcm : 81.1037
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 100.111
MBSY1c Hall A Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
MBSY1c Bdl : 849671
MBSY3c Hall C Beam energy : 885.574
Tiefenbach Hall A energy : 3399.18
Tiefenbach Hall C energy : 884.414
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00104079
IPM1H04A.XPOS : 1.7866
IPM1H04A.YPOS : 0.70822
IPM1H04B.XPOS : -0.00180681
IPM1H04B.YPOS : 0.0908318
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -1768
HacR_VPM_LVDT:VALr : 508
HacR_HPE1313A:0_Ch58 : -0.521484
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.885742
HacR_alignROLL : -0.406572
HacR_alignPITCH : -0.0327544
HacR_alignHPT : -0.844547
HacL_HPM_LVDT:VALr : -7058
HacL_VPM_LVDT:VALr : 1682
HacL_HPE1313A:0_Ch58 : -0.226074
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : 0.10498
HacL_alignROLL : 0.44139
HacL_alignPITCH : -0.0631283
HacL_alignHPT : 3.94253
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 65
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 19.67
haH2_P_Exhaust_R : 20.04
haH2_P_Fill_Bottle_R : 20.14
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.24
haD2_P_Fill_Bottle_R : 37.91
haD2_DP_Fill_Exhaust_R : 0.0741
haSC200_6_Sensor_1_R : 241.54
haSC200_6_Sensor_2_R : 27.22
haSC200_6_Sensor_3_R : 38.45
haSC200_6_Sensor_4_R : 41.01
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.92
haITC502_1_Sensor_2_R : 82.23
haITC502_1_Sensor_3_R : 75.79
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 18.99
haITC502_2_Sensor_3_R : 19.22
haITC502_4_Sensor_1_R : 83.8
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 90.35
haITC502_5_Sensor_2_R : 81.69
haITC502_5_Sensor_3_R : 264.5
haITC502_6_Sensor_1_R : 97.37
haITC502_6_Sensor_2_R : 81
haITC502_6_Sensor_3_R : 27.86
Right Arm Arm Collimator : 0.615186
Left Arm Arm Collimator : 0.616943
Wien angle : 51.3832
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1151.4
Wien field : 33.611
Laser attenuation Hall A : 476
Laser power Hall A : 57
Half-wave plate (off=out) : ON