• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 23:22:22 on March 16, 2001

    Entry number 58916

    keyword=End_of_Run_2974
    ****************************
     Run Number: 2974
    End of Run Comment:
    RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=kinematics18,mode=coincidence,Lmom=1.8930,Rmom=-0.788000,Ene=3.399,Angle_R=55.871,Angle_L=12.473
    
    
    Time of run = 132.15143 min
    Av. current (on 3x) = -53.652755 uA
    Av. current (on 1x) = 79.137042 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  627.4844  |  -425.4173  |  -123.7237
    up-down    (mC)|   -3.3920  |   20.7082  |  -23.8463
     Trigger   | Rate(Hz)   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      | 3375.3012 Hz  |    -62910.1 /mC  |    3.750 Hz  |  26763053  |   900   |     42651.3 /mC
        2      | 26333.879 Hz  |   -490820.6 /mC  |    7.524 Hz  | 208803590  |  3500   |    332763.0 /mC
        3      | -177773.44 Hz  |   3313407.3 /mC  |   -5.050 Hz  | -1409580800  | 35200   |  -2246399.8 /mC
        4      | 92611.192 Hz  |  -1726121.9 /mC  |    9.749 Hz  | 734322100  |  9500   |   1170263.5 /mC
        5      | 120.58263 Hz  |     -2247.5 /mC  |  120.583 Hz  |    956110  |     1   |      1523.7 /mC
     Trigger 5 corrected for pulser:
    
      5 (phys) | 110.40403 Hz  |     -2057.8 /mC  |  110.404 Hz  | 875403.0  |     1   |      1395.1 /mC
        8    | 1024.0 Hz  |    -19085.7 /mC  |    0.016 Hz  |   8119384  | 65535   |     12939.6 /mC
        output                       150.813 Hz
    Av. deadtime from accepted triggers = -0.1054
    Av. deadtime from gated scalers = -0.0900
    Accepted triggers  = 1195812.00000
    Rate of Left Arm Pulser for electronic DT  = 10.178601
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 9.9638219
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.02110102
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 88266.714
    Rate of Right Arm Strobe  = 30623.17
        Signal     |    Charge   (C)   
       upstream    |    0.6257884     
       upstream 3x |    -0.4150632     
       upstream 10x|    -0.1356469     
      downstream   |    0.6291804   
     downstream 3x |    -0.4357714   
     downstream 10x|    -0.1118006    
     
     
    
    ****************************
    End-of-run EPICS data for Run Number 2974 at Fri Mar 16 23:22:07 EST 2001
    Right Arm D1 momentum                    : 0.787999
    Right Arm arm angle                      : 55.8711
    Left Arm D1 momentum                      : 1.89301
    Left Arm arm angle                        : 12.473
    Tiefenbach Hall A energy                : 3399.2
    Right Arm arm mispointing (HPT)          : 2.37559
    Left Arm arm mispointing (HPT)            : 3.94068
    Right Arm Q1 power supply current        : 592.585
    Right Arm Q1 momentum                    : 0.78808
    Right Arm Q1 gauss meter                 : -0.014864
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 339.146
    Right Arm Q2 momentum                    : 0.78804
    Right Arm Q2 gauss meter                 : 0.17836
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 268.649
    Right Arm D1 momentum                    : 0.787999
    Right Arm D1 NMR                         : 0.292417
    Right Arm Q3 power supply current        : 313.413
    Right Arm Q3 momentum                    : 0.787651
    Right Arm Q3 gauss meter                 : 0.14055
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1424.11
    Left Arm Q1 momentum                      : 1.89294
    Left Arm Q1 gauss meter                   : 0.12111
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 815.427
    Left Arm Q2 momentum                      : 1.89316
    Left Arm Q2 gauss meter                   : -0.4296
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 640.19
    Left Arm D1 momentum                      : 1.89301
    Left Arm D1 NMR                           : 0.700504
    Left Arm Q3 power supply current          : 753.638
    Left Arm Q3 momentum                      : 1.893
    Left Arm Q3 gauss meter                   : 0.3763
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 86.2419
    Current on Unser monitor                : 93.4444
    Current on Upstream bcm                 : 86.1851
    Current on Downstream bcm               : 86.2988
    Upstream Cavity Coefficient             : 76.7
    Downstream Cavity Coefficient           : 78.1
     Current on IBC0L02 (source)            : 101.862
    MBSY1c Hall A Beam energy               : 3404.8
    MBSY1c magnet current (amp)             : 141.8
    MBSY1c Bdl                              : 849671
    MBSY3c Hall C Beam energy               : 885.574
    Tiefenbach Hall A energy                : 3399.2
    Tiefenbach Hall C energy                : 884.147
    Delta(E)/E width (MV_AI_DXWID)          : 15.6426
    IPM1C12.XPOS                            : -0.00173339
    IPM1H04A.XPOS                           : 1.74715
    IPM1H04A.YPOS                           : 0.719373
    IPM1H04B.XPOS                           : 0.000506584
    IPM1H04B.YPOS                           : 0.0209502
    Right Arm Arm Collimator                 : 0.615186
    Left Arm Arm Collimator                   : 0.616992
     HacR_HPM_LVDT:VALr                     : -4728
     HacR_VPM_LVDT:VALr                     : 570
     HacR_HPE1313A:0_Ch58                   : -0.514648
     HacR_HPE1313A:0_Ch55                   : 22.6074
     HacR_HPE1313A:0_Ch54                   : -0.796875
     HacR_alignROLL                         : -0.315922
     HacR_alignPITCH                        : -0.0389718
     HacR_alignHPT                          : 2.37527
     HacL_HPM_LVDT:VALr                     : -7057
     HacL_VPM_LVDT:VALr                     : 1759
     HacL_HPE1313A:0_Ch58                   : -0.225586
     HacL_HPE1313A:0_Ch55                   : 23.4375
     HacL_HPE1313A:0_Ch54                   : 0.106445
     HacL_alignROLL                         : 0.442546
     HacL_alignPITCH                        : -0.0629098
     HacL_alignHPT                          : 3.93974
    haBDSPOS                                 : 4.643e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 66
    haL3_Fan_frequency_R                     : 24.5
    haH2_P_Fill_Target_R                     : 19.6
    haH2_P_Exhaust_R                         : 20.03
    haH2_P_Fill_Bottle_R                     : 20.14
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : -999.99
    haD2_P_Exhaust_R                         : 18.15
    haD2_P_Fill_Bottle_R                     : 38.06
    haD2_DP_Fill_Exhaust_R                   : 0.0743
    haSC200_6_Sensor_1_R                     : 241.59
    haSC200_6_Sensor_2_R                     : 26.97
    haSC200_6_Sensor_3_R                     : 38.8
    haSC200_6_Sensor_4_R                     : 40.98
    haHe_Omega_DPG_Sensor_R                  : 0
    haITC502_1_Sensor_1_R                    : 83.05
    haITC502_1_Sensor_2_R                    : 82.37
    haITC502_1_Sensor_3_R                    : 75.76
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.23
    haITC502_4_Sensor_1_R                    : 83.5
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 21.9
    haITC502_5_Sensor_1_R                    : 90.59
    haITC502_5_Sensor_2_R                    : 81.91
    haITC502_5_Sensor_3_R                    : 263.7
    haITC502_6_Sensor_1_R                    : 97.38
    haITC502_6_Sensor_2_R                    : 80.91
    haITC502_6_Sensor_3_R                    : 28.35
    Right Arm Arm Collimator                 : 0.615137
    Left Arm Arm Collimator                   : 0.616895
    Wien angle                               : 51.3832
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1151.4
    Wien field                               : 33.611
    Laser attenuation Hall A                 : 395
    Laser power  Hall A                      : 57
    Half-wave plate (off=out)                : OFF