User name adev
Log entry time 20:14:24 on March 24, 2001
Entry number 59262
keyword=End_of_Run_3093
****************************
Run Number: 3093
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=production_kin20,mode=coincidence,Lmom=1.7410,Rmom=-0.8853,Ene=3.399,Angle_R=52.467,Angle_L=13.787 Adjusting Beam Current etc.
Time of run = 10.894629 min
Av. current (on 3x) = 40.603953 uA
Av. current (on 1x) = 40.510635 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 26.4809 | 26.5419 | 23.4115
up-down (mC)| -0.2197 | -0.0999 | -0.5052
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 1551.7723 Hz | 38217.3 /mC | 1.724 Hz | 1014359 | 900 | 38305.3 /mC
2 | 15811.313 Hz | 389403.3 /mC | 4.518 Hz | 10335503 | 3500 | 390300.3 /mC
3 | 201567.13 Hz | 4964224.5 /mC | 5.678 Hz | 131759950 | 35500 | 4975659.8 /mC
4 | 46626.014 Hz | 1148312.2 /mC | 4.908 Hz | 30478387 | 9500 | 1150957.4 /mC
5 | 65.093238 Hz | 1603.1 /mC | 65.093 Hz | 42550 | 1 | 1606.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 54.930738 Hz | 1352.8 /mC | 54.931 Hz | 35907.0 | 1 | 1356.0 /mC
8 | 1024.0 Hz | 25219.2 /mC | 0.016 Hz | 669366 | 65535 | 25277.3 /mC
output 80.876 Hz
Av. deadtime from accepted triggers = 0.0121
Av. deadtime from gated scalers = 0.0216
Accepted triggers = 52867.00000
Rate of Left Arm Pulser for electronic DT = 10.1625
Rate of Right Arm Pulser for electronic DT = 10.141083
Rate of Left Arm Pulser&trig for electronic DT = 10.029407
Rate of Right Arm Pulser&trig for electronic DT = 10.141083
Left Arm Electronic DT = 0.013096493
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 332788.21
Rate of Right Arm Strobe = 18288.922
Signal | Charge (C)
upstream | 0.0263711
upstream 3x | 0.0264920
upstream 10x| 0.0231589
downstream | 0.0265908
downstream 3x | 0.0265919
downstream 10x| 0.0236641
****************************
End-of-run EPICS data for Run Number 3093 at Sat Mar 24 20:14:13 EST 2001
Right Arm D1 momentum : 0.885301
Right Arm arm angle : 52.4674
Left Arm D1 momentum : 1.74101
Left Arm arm angle : 13.7872
Tiefenbach Hall A energy : 3399.23
Right Arm arm mispointing (HPT) : 2.19218
Left Arm arm mispointing (HPT) : 4.81419
Right Arm Q1 power supply current : 665.735
Right Arm Q1 momentum : 0.885363
Right Arm Q1 gauss meter : -0.016659
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 381.064
Right Arm Q2 momentum : 0.885439
Right Arm Q2 gauss meter : 0.2003
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 302.261
Right Arm D1 momentum : 0.885301
Right Arm D1 NMR : 0.328525
Right Arm Q3 power supply current : 352.399
Right Arm Q3 momentum : 0.885627
Right Arm Q3 gauss meter : 0.15792
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1309.67
Left Arm Q1 momentum : 1.74081
Left Arm Q1 gauss meter : 0.11148
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.617
Left Arm Q2 momentum : 1.74087
Left Arm Q2 gauss meter : -0.3951
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 586.407
Left Arm D1 momentum : 1.74101
Left Arm D1 NMR : 0.64429
Left Arm Q3 power supply current : 693.125
Left Arm Q3 momentum : 1.741
Left Arm Q3 gauss meter : 0.3461
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 93.9997
Current on Unser monitor : 102.116
Current on Upstream bcm : 94.1521
Current on Downstream bcm : 93.8473
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 94.4413
MBSY1c Hall A Beam energy : 3404.8
MBSY1c magnet current (amp) : 141.8
MBSY1c Bdl : 849671
MBSY3c Hall C Beam energy : 885.173
Tiefenbach Hall A energy : 3399.23
Tiefenbach Hall C energy : 883.972
Delta(E)/E width (MV_AI_DXWID) : 1.5441
IPM1C12.XPOS : -0.0011754
IPM1H04A.XPOS : 1.17436
IPM1H04A.YPOS : 0.278872
IPM1H04B.XPOS : -0.0550915
IPM1H04B.YPOS : 0.0238885
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.616943
HacR_HPM_LVDT:VALr : -4527
HacR_VPM_LVDT:VALr : 398
HacR_HPE1313A:0_Ch58 : -0.51416
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.803223
HacR_alignROLL : -0.322448
HacR_alignPITCH : -0.0392868
HacR_alignHPT : 2.19362
HacL_HPM_LVDT:VALr : -7822
HacL_VPM_LVDT:VALr : 1974
HacL_HPE1313A:0_Ch58 : -0.202148
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0634766
HacL_alignROLL : 0.401031
HacL_alignPITCH : -0.0841555
HacL_alignHPT : 4.81445
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 73.5
haL3_Fan_frequency_R : 25
haH2_P_Fill_Target_R : 19.98
haH2_P_Exhaust_R : 20.42
haH2_P_Fill_Bottle_R : 20.08
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.41
haD2_P_Fill_Bottle_R : 38.57
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 241.38
haSC200_6_Sensor_2_R : 28.34
haSC200_6_Sensor_3_R : 39.73
haSC200_6_Sensor_4_R : 41.04
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 81.9
haITC502_1_Sensor_2_R : 81.89
haITC502_1_Sensor_3_R : 84.3
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.24
haITC502_4_Sensor_1_R : 86.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 82.7
haITC502_5_Sensor_2_R : 82.05
haITC502_5_Sensor_3_R : 261.8
haITC502_6_Sensor_1_R : 82.21
haITC502_6_Sensor_2_R : 82.56
haITC502_6_Sensor_3_R : 28.22
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 316
Laser power Hall A : 57
Half-wave plate (off=out) : OFF