User name adev
Log entry time 03:16:40 on March 30, 2001
Entry number 59565
keyword=End_of_Run_3203
****************************
Run Number: 3203
End of Run Comment:
RunType=pion_prod,Tar=LH2-15cm,Rad=out,comment=production_kin22,mode=coincidence,Lmom=2.542,Rmom=-1.120,Ene=4.232,Angle_R=40.775,Angle_L=12.530
Time of run = 75.035205 min
Av. current (on 3x) = 80.72573 uA
Av. current (on 1x) = 80.540061 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 362.6004 | 363.4363 | -25.8191
up-down (mC)| -3.1336 | -1.2604 | -13.6389
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 8487.1739 Hz | 105135.9 /mC | 7.716 Hz | 38210210 | 1100 | 105378.3 /mC
2 | 38805.097 Hz | 480703.0 /mC | 11.087 Hz | 174704910 | 3500 | 481811.1 /mC
3 | 208350.08 Hz | 2580962.5 /mC | 5.869 Hz | 938015450 | 35500 | 2586912.3 /mC
4 | 88679.21 Hz | 1098524.7 /mC | 9.335 Hz | 399243760 | 9500 | 1101057.1 /mC
5 | 192.8748 Hz | 2389.3 /mC | 192.875 Hz | 868344 | 1 | 2394.8 /mC
Trigger 5 corrected for pulser:
5 (phys) | 182.70224 Hz | 2263.2 /mC | 182.702 Hz | 822546.0 | 1 | 2268.5 /mC
8 | 1024.0 Hz | 12684.9 /mC | 0.016 Hz | 4610163 | 65535 | 12714.2 /mC
output 221.746 Hz
Av. deadtime from accepted triggers = 0.0219
Av. deadtime from gated scalers = -0.3214
Accepted triggers = 998327.00000
Rate of Left Arm Pulser for electronic DT = 10.172558
Rate of Right Arm Pulser for electronic DT = 10.18322
Rate of Left Arm Pulser&trig for electronic DT = 10.053725
Rate of Right Arm Pulser&trig for electronic DT = 10.18322
Left Arm Electronic DT = 0.011681733
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 398030.1
Rate of Right Arm Strobe = 51729.255
Signal | Charge (C)
upstream | 0.3610336
upstream 3x | 0.3628061
upstream 10x| -0.0326385
downstream | 0.3641672
downstream 3x | 0.3640665
downstream 10x| -0.0189996
****************************
End-of-run EPICS data for Run Number 3203 at Fri Mar 30 03:16:25 EST 2001
Right Arm D1 momentum : 1.12
Right Arm arm angle : 40.7748
Left Arm D1 momentum : 2.542
Left Arm arm angle : 12.5299
Tiefenbach Hall A energy : 4237
Right Arm arm mispointing (HPT) : 2.12638
Left Arm arm mispointing (HPT) : 4.22559
Right Arm Q1 power supply current : 842.1
Right Arm Q1 momentum : 1.11991
Right Arm Q1 gauss meter : -0.021047
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 482.035
Right Arm Q2 momentum : 1.12005
Right Arm Q2 gauss meter : 0.2534
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 382.938
Right Arm D1 momentum : 1.12
Right Arm D1 NMR : 0.415618
Right Arm Q3 power supply current : 445.741
Right Arm Q3 momentum : 1.12021
Right Arm Q3 gauss meter : 0.19963
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1912.47
Left Arm Q1 momentum : 2.54206
Left Arm Q1 gauss meter : 0.16222
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1094.32
Left Arm Q2 momentum : 2.54138
Left Arm Q2 gauss meter : -0.5764
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 877.538
Left Arm D1 momentum : 2.542
Left Arm D1 NMR : 0.940891
Left Arm Q3 power supply current : 1012.07
Left Arm Q3 momentum : 2.54214
Left Arm Q3 gauss meter : 0.5052
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 89.3957
Current on Unser monitor : 96.135
Current on Upstream bcm : 89.3485
Current on Downstream bcm : 89.4429
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 137.868
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4237
Tiefenbach Hall C energy : 884.237
Delta(E)/E width (MV_AI_DXWID) : 8.04495
IPM1C12.XPOS : -0.000451267
IPM1H04A.XPOS : 0.908685
IPM1H04A.YPOS : 0.300879
IPM1H04B.XPOS : 0.00546742
IPM1H04B.YPOS : -0.0571115
Right Arm Arm Collimator : 0.615088
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -4376
HacR_VPM_LVDT:VALr : 477
HacR_HPE1313A:0_Ch58 : -0.526855
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.93457
HacR_alignROLL : -0.45598
HacR_alignPITCH : -0.0276832
HacR_alignHPT : 2.1261
HacL_HPM_LVDT:VALr : -7309
HacL_VPM_LVDT:VALr : 1632
HacL_HPE1313A:0_Ch58 : -0.223145
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0942383
HacL_alignROLL : 0.430929
HacL_alignPITCH : -0.0664024
HacL_alignHPT : 4.2269
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 19.5
haL2_Fan_frequency_R : 69.5
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.32
haH2_P_Exhaust_R : 20.66
haH2_P_Fill_Bottle_R : 20.41
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.67
haD2_P_Fill_Bottle_R : 38.86
haD2_DP_Fill_Exhaust_R : 0.0745
haSC200_6_Sensor_1_R : 241.34
haSC200_6_Sensor_2_R : 28.13
haSC200_6_Sensor_3_R : 40.31
haSC200_6_Sensor_4_R : 41.14
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 82.7
haITC502_1_Sensor_2_R : 82.68
haITC502_1_Sensor_3_R : 85.04
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.25
haITC502_4_Sensor_1_R : 0
haITC502_4_Sensor_2_R : 0
haITC502_4_Sensor_3_R : 0
haITC502_5_Sensor_1_R : 83.51
haITC502_5_Sensor_2_R : 82.84
haITC502_5_Sensor_3_R : 260.7
haITC502_6_Sensor_1_R : 83.07
haITC502_6_Sensor_2_R : 83.39
haITC502_6_Sensor_3_R : 28.15
Right Arm Arm Collimator : 0.615039
Left Arm Arm Collimator : 0.616992
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 419
Laser power Hall A : 57
Half-wave plate (off=out) : ON