Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 19:18:44 on April 3, 2001
Entry number 59882
keyword=End_of_Run_3339
****************************
Run Number: 3339
End of Run Comment:
RunType=Other,Tar=LH2-15cm,Rad=out,comment=kin23,mode=coincidence,Lmom=1.741,Rmom=-1.6880,Ene=4.232,Angle_R=32.991,Angle_L=18.555
Time of run = 2.367985 min
Av. current (on 3x) = 4.9585055 uA
Av. current (on 1x) = 4.9366867 uA
| on 1x | on 3x | on 10x
Av. charge (mC)| 0.7014 | 0.7045 | 0.7074
up-down (mC)| 0.0002 | -0.0066 | -0.0027
Trigger | Rate(Hz) | Scaler/charge(3x)|Scaler/time/ps| Scaler | Prescale| Scaler/charge(1x)
1 | 259.18661 Hz | 52271.1 /mC | 2.592 Hz | 36825 | 100 | 52502.1 /mC
2 | 4035.4282 Hz | 813839.6 /mC | 1.153 Hz | 573350 | 3500 | 817436.6 /mC
3 | 20015.991 Hz | 4036698.4 /mC | 56.383 Hz | 2843854 | 355 | 4054539.5 /mC
4 | 5935.2431 Hz | 1196982.3 /mC | 0.625 Hz | 843274 | 9500 | 1202272.6 /mC
5 | 11.043144 Hz | 2227.1 /mC | 11.043 Hz | 1569 | 1 | 2237.0 /mC
Trigger 5 corrected for pulser:
5 (phys) | 0.851638 Hz | 171.8 /mC | 0.852 Hz | 121.0 | 1 | 172.5 /mC
8 | 1024.0 Hz | 206513.8 /mC | 0.016 Hz | 145489 | 65535 | 207426.6 /mC
output 71.481 Hz
Av. deadtime from accepted triggers = 0.0026
Av. deadtime from gated scalers = 0.0097
Accepted triggers = 10156.00000
Rate of Left Arm Pulser for electronic DT = 10.191506
Rate of Right Arm Pulser for electronic DT = 10.332273
Rate of Left Arm Pulser&trig for electronic DT = 10.184468
Rate of Right Arm Pulser&trig for electronic DT = 10.332273
Left Arm Electronic DT = 0.00069060773
Right Arm Electronic DT = 0.0
Rate of Left Strobe = 34333.065
Rate of Right Arm Strobe = 4379.6871
Signal | Charge (C)
upstream | 0.0007015
upstream 3x | 0.0007012
upstream 10x| 0.0007060
downstream | 0.0007013
downstream 3x | 0.0007078
downstream 10x| 0.0007087
****************************
End-of-run EPICS data for Run Number 3339 at Tue Apr 3 19:18:27 EDT 2001
Right Arm D1 momentum : 1.688
Right Arm arm angle : 32.991
Left Arm D1 momentum : 1.741
Left Arm arm angle : 18.5551
Tiefenbach Hall A energy : 4236.97
Right Arm arm mispointing (HPT) : -0.171887
Left Arm arm mispointing (HPT) : 5.00566
Right Arm Q1 power supply current : 1269.24
Right Arm Q1 momentum : 1.68797
Right Arm Q1 gauss meter : -0.0316
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 726.459
Right Arm Q2 momentum : 1.688
Right Arm Q2 gauss meter : 0.3818
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 581.855
Right Arm D1 momentum : 1.688
Right Arm D1 NMR : 0.626396
Right Arm Q3 power supply current : 671.515
Right Arm Q3 momentum : 1.68761
Right Arm Q3 gauss meter : 0.3013
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1309.59
Left Arm Q1 momentum : 1.74072
Left Arm Q1 gauss meter : 0.11149
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 749.532
Left Arm Q2 momentum : 1.74067
Left Arm Q2 gauss meter : -0.3952
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 585.645
Left Arm D1 momentum : 1.741
Left Arm D1 NMR : 0.644288
Left Arm Q3 power supply current : 693.057
Left Arm Q3 momentum : 1.74083
Left Arm Q3 gauss meter : 0.346
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 4.92737
Current on Unser monitor : 12.6987
Current on Upstream bcm : 5.04947
Current on Downstream bcm : 5.054
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 47.5994
MBSY1c Hall A Beam energy : 4245.79
MBSY1c magnet current (amp) : 176.993
MBSY1c Bdl : 1.05954e+06
MBSY3c Hall C Beam energy : 885.654
Tiefenbach Hall A energy : 4237
Tiefenbach Hall C energy : 884.197
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.0527118
IPM1H04A.XPOS : 0.852765
IPM1H04A.YPOS : 0.0141802
IPM1H04B.XPOS : -0.0258281
IPM1H04B.YPOS : -0.0925844
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
HacR_HPM_LVDT:VALr : -2376
HacR_VPM_LVDT:VALr : 333
HacR_HPE1313A:0_Ch58 : -0.53125
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.789062
HacR_alignROLL : -0.308469
HacR_alignPITCH : -0.0242255
HacR_alignHPT : -0.171325
HacL_HPM_LVDT:VALr : -7921
HacL_VPM_LVDT:VALr : 2222
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.4863
HacL_HPE1313A:0_Ch54 : -0.11084
HacL_alignROLL : 0.23778
HacL_alignPITCH : -0.111199
HacL_alignHPT : 5.00343
haBDSPOS : 4.643e+06
haL1_Fan_frequency_R : 20
haL2_Fan_frequency_R : 71
haL3_Fan_frequency_R : 24.5
haH2_P_Fill_Target_R : 20.17
haH2_P_Exhaust_R : 20.51
haH2_P_Fill_Bottle_R : 20.24
haH2_DP_Fill_Exhaust_R : 0
haD2_P_Fill_Target_R : -999.99
haD2_P_Exhaust_R : 18.42
haD2_P_Fill_Bottle_R : 38.43
haD2_DP_Fill_Exhaust_R : 0.0746
haSC200_6_Sensor_1_R : 241.69
haSC200_6_Sensor_2_R : 28.39
haSC200_6_Sensor_3_R : 41.03
haSC200_6_Sensor_4_R : 41.46
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 85.84
haITC502_1_Sensor_2_R : 85.83
haITC502_1_Sensor_3_R : 88.28
haITC502_2_Sensor_1_R : 19
haITC502_2_Sensor_2_R : 19
haITC502_2_Sensor_3_R : 19.03
haITC502_4_Sensor_1_R : 90.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 86.46
haITC502_5_Sensor_2_R : 85.97
haITC502_5_Sensor_3_R : 260.6
haITC502_6_Sensor_1_R : 86.03
haITC502_6_Sensor_2_R : 86.45
haITC502_6_Sensor_3_R : 28.12
Right Arm Arm Collimator : 0.615137
Left Arm Arm Collimator : 0.616992
Wien angle : 61.2233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1382.7
Wien field : 40.224
Laser attenuation Hall A : 189
Laser power Hall A : 57
Half-wave plate (off=out) : ON