User name adev
Log entry time 13:14:01 on April 19, 2001
Entry number 60803
keyword=Start_Run_3693_RunType=Harp,Tar=carbon,Rad=out,comment=ep_scan,mode=coincidence,Lmom=2.377,Rmom=2.377,Ene=3995,Angle_R=32.841,Angle_L=32.762
Beginning-of-run EPICS data for Run Number 3693 at Thu Apr 19 13:13:51 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string (and I MEAN IT !!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=7,ps2=625,ps3=9,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=2
Right Arm Q1 power supply current : 1787.42
Right Arm Q1 momentum : 2.37709
Right Arm Q1 gauss meter : 0.04465
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1023.17
Right Arm Q2 momentum : 2.37743
Right Arm Q2 gauss meter : -0.5382
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 813.517
Right Arm D1 momentum : 2.13088
Right Arm D1 NMR : 0.790746
Right Arm Q3 power supply current : 945.968
Right Arm Q3 momentum : 2.37735
Right Arm Q3 gauss meter : -0.4241
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1788.29
Left Arm Q1 momentum : 2.377
Left Arm Q1 gauss meter : -0.15116
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1023.35
Left Arm Q2 momentum : 2.37657
Left Arm Q2 gauss meter : 0.5396
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 815.736
Left Arm D1 momentum : 2.37701
Left Arm D1 NMR : 0.879671
Left Arm Q3 power supply current : 946.251
Left Arm Q3 momentum : 2.37681
Left Arm Q3 gauss meter : -0.4721
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 5.1258
Current on Unser monitor : 12.5966
Current on Upstream bcm : 5.06648
Current on Downstream bcm : 5.06315
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 55.9992
Beam energy : 4007.97
MBSY1c magnet current (amp) : 167.035
Radiator 5V Linear Supply : 4.99145
Radiator Encoder : 0.161172
haBDSPOS : 682848
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 64.5
haL3_Fan_frequency_R : 24.5
haSC200_6_Sensor_1_R : 242.16
haSC200_6_Sensor_2_R : 26.87
haSC200_6_Sensor_3_R : 43.55
haSC200_6_Sensor_4_R : 41.91
haHe_Omega_DPG_Sensor_R : 0
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 82.36
haITC502_4_Sensor_1_R : 88.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 21.9
haITC502_5_Sensor_1_R : 0
haITC502_5_Sensor_2_R : 3.99
haITC502_5_Sensor_3_R : 10
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 87.29
haITC502_6_Sensor_3_R : 28.71
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617041
HacR_HPM_LVDT:VALr : -937
HacR_VPM_LVDT:VALr : 524
HacR_HPE1313A:0_Ch58 : -0.531738
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.820312
HacR_alignROLL : -0.339962
HacR_alignPITCH : -0.0229454
HacR_alignHPT : -1.76409
HacL_HPM_LVDT:VALr : -8393
HacL_VPM_LVDT:VALr : 866
HacL_HPE1313A:0_Ch58 : -0.16748
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.268066
HacL_alignROLL : 0.0955234
HacL_alignPITCH : -0.0963601
HacL_alignHPT : 5.6118
Right Arm Angle Floor Angle : 32.5
Right Arm Angle Vernier : 23
Right Arm Scattering Angle : 32.8415
Left Arm Angle Floor Angle : 33
Left Arm Angle Vernier : -3.6
Left Arm Scattering Angle : 32.7622
Wien angle : 36.5716
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 811.44
Wien field : 23.657
Laser attenuation Hall A : 210
Laser power Hall A : 57
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88