NEXT
User name a-onl
Log entry time 15:06:43 on October 16, 2001
Entry number 74829
keyword=End_of_Run_1142
****************************
Run Number: 1142
End of Run Comment:
Run_type=cosmics,beam_energy=,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=Cosmic run aerogels, test,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_halfwaveplate=out,target_name=TEST,target_polarization=,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=65535
EVENTS[0]: 474260 [+]: 233049 [-]: 232468
TIME [0]: 185.214 mins [+]: 90.894 mins [-]: 90.901 mins
LIVE [0]: 179.81% [+]: 179.93% [-]: 179.65%
TRIGGER RATES:
T1[0] [PRES/REAL]:10.1/10.1 Hz T2[0] [PRES/REAL]:13.6/13.6 Hz T8[0] [PRES/REAL]: 0.0/1024.0 Hz
T1[+] [PRES/REAL]:10.1/10.1 Hz T2[+] [PRES/REAL]:13.6/13.6 Hz T8[+] [PRES/REAL]: 0.0/1024.0 Hz
T1[-] [PRES/REAL]:10.1/10.1 Hz T2[-] [PRES/REAL]:13.6/13.6 Hz T8[-] [PRES/REAL]: 0.0/1024.0 Hz
TRIGGER TOTALS:
T1[0] [PRES/REAL]: 112318/112318 T2[0] [PRES/REAL]: 151268/151268 T8[0] [PRES/REAL]: 173/11379549
T1[+] [PRES/REAL]: 55060/55060 T2[+] [PRES/REAL]: 74376/74376 T8[+] [PRES/REAL]: 85/5584531
T1[-] [PRES/REAL]: 55219/55219 T2[-] [PRES/REAL]: 74093/74093 T8[-] [PRES/REAL]: 85/5584937
AVERAGE CURRENT
BCM x1 : 0.0018 uA BCM x3 : 0.0240 uA BCM x10: 0.0389 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :2.026E+04 ppm BCM u3 :5.353E+04 ppm BCM u10: 771.7 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1485 ppm BCM d10: 401.6 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0001158 BCM u3 [0]:1.748E-05 BCM u10[0]:0.0003229
BCM u1 [+]:5.546E-05 BCM u3 [+]:9.449E-06 BCM u10[+]:0.0001588
BCM u1 [-]:5.326E-05 BCM u3 [-]:8.49E-06 BCM u10[-]:0.0001586
BCM d1 [0]:-7.591E-05 BCM d3 [0]:0.0005156 BCM d10[0]:0.000542
BCM d1 [+]:-3.696E-05 BCM d3 [+]:0.0002543 BCM d10[+]:0.0002668
BCM d1 [-]:-4.009E-05 BCM d3 [-]:0.0002536 BCM d10[-]:0.0002666
****************************
End-of-run EPICS data for Run Number 1142 at Tue Oct 16 15:06:15 EDT 2001
Right Arm D1 momentum : 1.066
Right Arm arm angle :
Left Arm D1 momentum : 4.30001
Left Arm arm angle : 12.4997
Tiefenbach Hall A energy :
Right Arm arm mispointing (HPT) :
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current :
Right Arm Q1 momentum :
Right Arm Q1 gauss meter :
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current :
Right Arm Q2 momentum :
Right Arm Q2 gauss meter :
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current :
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.39558
Right Arm Q3 power supply current :
Right Arm Q3 momentum :
Right Arm Q3 gauss meter :
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3235.65
Left Arm Q1 momentum : 4.30082
Left Arm Q1 gauss meter : -0.2732
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.190273
Left Arm Q2 momentum : 0.000441878
Left Arm Q2 gauss meter : 0.003621
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1677
Left Arm D1 momentum : 4.30001
Left Arm D1 NMR : 1.59323
Left Arm Q3 power supply current : 2.09622
Left Arm Q3 momentum :
Left Arm Q3 gauss meter : 0.0002461
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0698329
Current on Unser monitor : 6.9639
Current on Upstream bcm : 0.0580017
Current on Downstream bcm : 0.0816642
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) :
MBSY1c Hall A Beam energy : 5738.82
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.43213e+06
MBSY3c Hall C Beam energy : 3493.3
Tiefenbach Hall A energy : 5727
Tiefenbach Hall C energy : 3483.86
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position : 0
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0962182
Waterfall Tachometer : 0.525521
Waterfall Encoder : 1.15249
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator : 0.617041
HacR_HPE1313A:0_Ch58 : -0.516113
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.856445
HacR_alignROLL :
HacR_alignPITCH :
HacR_alignHPT :
HacL_HPE1313A:0_Ch58 : -0.210938
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : 0.102539
HacL_alignROLL : 0.286392
HacL_alignPITCH : 0.104029
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.614844
Left Arm Arm Collimator : 0.616992
Laser attenuation Hall A :
Laser power Hall A :
OTR x-position : -6.7914
OTR y-position : 3.57362
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position : 0
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0999548
Waterfall Tachometer : -13.0098
Waterfall Encoder : 1.15337