NEXT
User name a-onl
Log entry time 18:27:23 on October 16, 2001
Entry number 74837
keyword=End_of_Run_1147
****************************
Run Number: 1147
End of Run Comment:
Run_type=cosmics,beam_energy=,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=Cosmic run,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_halfwaveplate=out,target_name=TEST,target_polarization=,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=65535
EVENTS[0]: 16896 [+]: 8276 [-]: 8349
TIME [0]: 6.547 mins [+]: 3.213 mins [-]: 3.213 mins
LIVE [0]: 179.40% [+]: 179.37% [-]: 179.20%
TRIGGER RATES:
T1[0] [PRES/REAL]:10.1/10.1 Hz T2[0] [PRES/REAL]:13.9/13.9 Hz T8[0] [PRES/REAL]: 0.0/1024.0 Hz
T1[+] [PRES/REAL]:10.2/10.2 Hz T2[+] [PRES/REAL]:13.8/13.8 Hz T8[+] [PRES/REAL]: 0.0/1024.0 Hz
T1[-] [PRES/REAL]:10.1/10.1 Hz T2[-] [PRES/REAL]:14.1/14.1 Hz T8[-] [PRES/REAL]: 0.0/1024.0 Hz
TRIGGER TOTALS:
T1[0] [PRES/REAL]: 3962/3962 T2[0] [PRES/REAL]: 5450/5450 T8[0] [PRES/REAL]: 6/402275
T1[+] [PRES/REAL]: 1957/1957 T2[+] [PRES/REAL]: 2654/2654 T8[+] [PRES/REAL]: 3/197383
T1[-] [PRES/REAL]: 1938/1938 T2[-] [PRES/REAL]: 2718/2718 T8[-] [PRES/REAL]: 3/197415
AVERAGE CURRENT
BCM x1 : 0.0074 uA BCM x3 : 0.0274 uA BCM x10: 0.0415 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :1.311E+04 ppm BCM u3 : 7367 ppm BCM u10: 254.8 ppm
BCM d1 : 1E+39 ppm BCM d3 : 1483 ppm BCM d10: 403.5 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:7.078E-06 BCM u3 [0]:3.065E-06 BCM u10[0]:1.333E-05
BCM u1 [+]:3.43E-06 BCM u3 [+]:1.525E-06 BCM u10[+]:6.542E-06
BCM u1 [-]:3.342E-06 BCM u3 [-]:1.503E-06 BCM u10[-]:6.54E-06
BCM d1 [0]:-1.238E-06 BCM d3 [0]:1.847E-05 BCM d10[0]:1.927E-05
BCM d1 [+]:-6.226E-07 BCM d3 [+]:9.112E-06 BCM d10[+]:9.479E-06
BCM d1 [-]:-7.013E-07 BCM d3 [-]:9.087E-06 BCM d10[-]:9.473E-06
****************************
End-of-run EPICS data for Run Number 1147 at Tue Oct 16 18:26:39 EDT 2001
Right Arm D1 momentum : 0
Right Arm arm angle :
Left Arm D1 momentum : 4.30001
Left Arm arm angle : 12.4997
Tiefenbach Hall A energy :
Right Arm arm mispointing (HPT) :
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current :
Right Arm Q1 momentum :
Right Arm Q1 gauss meter :
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current :
Right Arm Q2 momentum :
Right Arm Q2 gauss meter :
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current :
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.349971
Right Arm Q3 power supply current :
Right Arm Q3 momentum :
Right Arm Q3 gauss meter :
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.0002753
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.268978
Left Arm Q2 momentum : 0.000624658
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1676.98
Left Arm D1 momentum : 4.3
Left Arm D1 NMR : 1.59322
Left Arm Q3 power supply current : 1.78526
Left Arm Q3 momentum : 0.00448423
Left Arm Q3 gauss meter : 0.0002706
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0712432
Current on Unser monitor : 6.87394
Current on Upstream bcm : 0.0633836
Current on Downstream bcm : 0.0791027
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) :
MBSY1c Hall A Beam energy : 5738.82
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.43213e+06
MBSY3c Hall C Beam energy : 3493.3
Tiefenbach Hall A energy : 5727
Tiefenbach Hall C energy : 3483.86
Delta(E)/E width (MV_AI_DXWID) :
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position : 0
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0924816
Waterfall Tachometer : 2.21744
Waterfall Encoder : 1.15082
Right Arm Arm Collimator :
Left Arm Arm Collimator : 0.617041
HacR_HPE1313A:0_Ch58 : -0.515625
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.854492
HacR_alignROLL :
HacR_alignPITCH :
HacR_alignHPT :
HacL_HPE1313A:0_Ch58 : -0.209961
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : 0.102051
HacL_alignROLL : 0.284611
HacL_alignPITCH : 0.105412
HacL_alignHPT : -0
Right Arm Arm Collimator :
Left Arm Arm Collimator : 0.617041
Laser attenuation Hall A :
Laser power Hall A :
OTR x-position : -6.7914
OTR y-position : 3.57362
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position : 0
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.047642
Waterfall Tachometer : -1.1664