NEXT
User name a-onl
Log entry time 00:40:03 on October 17, 2001
Entry number 74854
keyword=End_of_Run_1155
****************************
Run Number: 1155
End of Run Comment:
Run_type=cosmics,beam_energy=,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=Cosmic run,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_halfwaveplate=out,target_name=TEST,target_polarization=,target_type=Empty
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=1 ps5=1 ps8=65535
EVENTS[0]: 18521 [+]: 9030 [-]: 9132
TIME [0]: 7.251 mins [+]: 3.557 mins [-]: 3.558 mins
LIVE [0]: 181.13% [+]: 180.42% [-]: 181.73%
TRIGGER RATES:
T1[0] [PRES/REAL]: 9.8/9.8 Hz T2[0] [PRES/REAL]:13.7/13.7 Hz T8[0] [PRES/REAL]: 0.0/1024.0 Hz
T1[+] [PRES/REAL]: 9.8/9.8 Hz T2[+] [PRES/REAL]:13.7/13.7 Hz T8[+] [PRES/REAL]: 0.0/1024.0 Hz
T1[-] [PRES/REAL]: 9.7/9.7 Hz T2[-] [PRES/REAL]:13.8/13.8 Hz T8[-] [PRES/REAL]: 0.0/1024.0 Hz
TRIGGER TOTALS:
T1[0] [PRES/REAL]: 4242/4242 T2[0] [PRES/REAL]: 5977/5977 T8[0] [PRES/REAL]: 6/445483
T1[+] [PRES/REAL]: 2081/2081 T2[+] [PRES/REAL]: 2921/2921 T8[+] [PRES/REAL]: 3/218533
T1[-] [PRES/REAL]: 2073/2073 T2[-] [PRES/REAL]: 2949/2949 T8[-] [PRES/REAL]: 3/218618
AVERAGE CURRENT
BCM x1 : 0.0075 uA BCM x3 : 0.0277 uA BCM x10: 0.0418 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 6281 ppm BCM u3 : 4118 ppm BCM u10: 590.3 ppm
BCM d1 : 1E+39 ppm BCM d3 : 2046 ppm BCM d10: 817.7 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:7.986E-06 BCM u3 [0]:3.429E-06 BCM u10[0]:1.49E-05
BCM u1 [+]:3.843E-06 BCM u3 [+]:1.693E-06 BCM u10[+]:7.315E-06
BCM u1 [-]:3.796E-06 BCM u3 [-]:1.68E-06 BCM u10[-]:7.309E-06
BCM d1 [0]:-1.47E-06 BCM d3 [0]:2.07E-05 BCM d10[0]:2.145E-05
BCM d1 [+]:-7.266E-07 BCM d3 [+]:1.022E-05 BCM d10[+]:1.056E-05
BCM d1 [-]:-8.444E-07 BCM d3 [-]:1.018E-05 BCM d10[-]:1.055E-05
****************************
End-of-run EPICS data for Run Number 1155 at Tue Oct 16 19:46:39 EDT 2001
Right Arm D1 momentum : 0
Right Arm arm angle :
Left Arm D1 momentum : 4.30001
Left Arm arm angle : 12.4997
Tiefenbach Hall A energy :
Right Arm arm mispointing (HPT) :
Left Arm arm mispointing (HPT) : -0
Right Arm Q1 power supply current :
Right Arm Q1 momentum :
Right Arm Q1 gauss meter :
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current :
Right Arm Q2 momentum :
Right Arm Q2 gauss meter :
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current :
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.410537
Right Arm Q3 power supply current :
Right Arm Q3 momentum :
Right Arm Q3 gauss meter :
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0
Left Arm Q1 gauss meter : 0.000252
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.269786
Left Arm Q2 momentum : 0.000619868
Left Arm Q2 gauss meter : 0.0010995
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1676.98
Left Arm D1 momentum : 4.3
Left Arm D1 NMR : 1.59322
Left Arm Q3 power supply current : 1.76497
Left Arm Q3 momentum : 0.00443329
Left Arm Q3 gauss meter : 0.0002633
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0720769
Current on Unser monitor : 7.14018
Current on Upstream bcm : 0.0651277
Current on Downstream bcm : 0.0790262
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) :
MBSY1c Hall A Beam energy : 5738.82
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.43213e+06
MBSY3c Hall C Beam energy : 3493.3
Tiefenbach Hall A energy : 5727
Tiefenbach Hall C energy : 3483.86
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0 !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur.
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Waterfall Step Motor Position : 0
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.11677
Waterfall Tachometer : -7.93408
Waterfall Encoder : 1.15356
Right Arm Arm Collimator : 0.614893
Left Arm Arm Collimator :
HacR_HPE1313A:0_Ch58 : -0.515137
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.852051
HacR_alignROLL :
HacR_alignPITCH :
HacR_alignHPT :
HacL_HPE1313A:0_Ch58 : -0.209961
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : 0.101074
HacL_alignROLL : 0.284068
HacL_alignPITCH : 0.104466
HacL_alignHPT : -0
Right Arm Arm Collimator : 0.614795
Left Arm Arm Collimator : 0.616992
Laser attenuation Hall A :
Laser power Hall A :
OTR x-position : -6.7914
OTR y-position : 3.57362
OTR x-width : 0
OTR y-width : -0
OTR data valid flag : No
Waterfall Step Motor Position : 0
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0868766
Waterfall Tachometer : -40.564
Waterfall Encoder : 1.15347