    User name a-onl

    Log entry time 20:16:47 on October 17, 2001

    Entry number 74859

    keyword=End_of_Run_1158
    ****************************
     Run Number: 1158
     End of Run Comment:
    Run_type=cosmics,beam_energy=,beam_halfwaveplate=out,beam_polarization=,beam_raster=off,comment_text=Cosmic run,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_halfwaveplate=out,target_name=TEST,target_polarization=,target_type=Empty
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 36750        [+]: 17938        [-]: 18114        
    TIME  [0]: 14.378 mins  [+]: 7.055 mins  [-]: 7.055 mins  
    LIVE  [0]: 179.78%      [+]: 179.99%      [-]: 179.60%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:10.2/10.2 Hz   T2[0] [PRES/REAL]:13.5/13.5 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:10.2/10.2 Hz   T2[+] [PRES/REAL]:13.3/13.3 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:10.0/10.0 Hz   T2[-] [PRES/REAL]:13.8/13.8 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:   8760/8760     T2[0] [PRES/REAL]:  11669/11669    T8[0] [PRES/REAL]:     13/883407   
    T1[+] [PRES/REAL]:   4337/4337     T2[+] [PRES/REAL]:   5623/5623     T8[+] [PRES/REAL]:      6/433453   
    T1[-] [PRES/REAL]:   4243/4243     T2[-] [PRES/REAL]:   5837/5837     T8[-] [PRES/REAL]:      6/433469   
    
    AVERAGE CURRENT
    BCM x1 : -0.0008uA  BCM x3 : 0.0196 uA  BCM x10: 0.0335 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :1.576E+05 ppm     BCM u3 :    1E+39 ppm     BCM u10:     1222 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :     1980 ppm     BCM d10:    254.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:1.476E-06      BCM u3 [0]:-5.767E-06     BCM u10[0]:1.672E-05      
    BCM u1 [+]:5.865E-07      BCM u3 [+]:-2.754E-06     BCM u10[+]:8.214E-06      
    BCM u1 [-]:4.268E-07      BCM u3 [-]:-2.876E-06     BCM u10[-]:8.194E-06      
    
    BCM d1 [0]:-2.773E-06     BCM d3 [0]:3.956E-05      BCM d10[0]:4.115E-05      
    BCM d1 [+]:-1.36E-06      BCM d3 [+]:1.953E-05      BCM d10[+]:2.026E-05      
    BCM d1 [-]:-1.626E-06     BCM d3 [-]:1.946E-05      BCM d10[-]:2.025E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1158 at Wed Oct 17 20:16:19 EDT 2001
    Right Arm D1 momentum : 0
    Right Arm arm angle :
    Left Arm D1 momentum : 0
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy :
    Right Arm arm mispointing (HPT) :
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum :
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current :
    Right Arm Q2 momentum :
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current :
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.334984
    Right Arm Q3 power supply current :
    Right Arm Q3 momentum :
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 1e+06
    Left Arm Q1 momentum : 1329.2
    Left Arm Q1 gauss meter : 0.0002517
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : -0.000183426
    Left Arm Q2 momentum : -4.25978e-07
    Left Arm Q2 gauss meter : 0.0008843
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 0.124163
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.358391
    Left Arm Q3 power supply current : -0.000116045
    Left Arm Q3 momentum : -2.91484e-07
    Left Arm Q3 gauss meter : 0.0002659
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0612975
    Current on Unser monitor : 6.68883
    Current on Upstream bcm : 0.0458975
    Current on Downstream bcm : 0.0766975
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) :
    MBSY1c Hall A Beam energy : 5738.82
    MBSY1c magnet current (amp) : 0.0377197
    MBSY1c Bdl : 1.43213e+06
    MBSY3c Hall C Beam energy : 3493.3
    Tiefenbach Hall A energy : 5727
    Tiefenbach Hall C energy : 3483.86
    Delta(E)/E width (MV_AI_DXWID) : 1.2011
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : 0
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.0980865
    Waterfall Tachometer : 0.283818
    Waterfall Encoder : 1.15249
    Right Arm Arm Collimator : 0.614844
    Left Arm Arm Collimator : 0.617041
    HacR_HPE1313A:0_Ch58 : -0.515137
    HacR_HPE1313A:0_Ch55 : 22.4121
    HacR_HPE1313A:0_Ch54 : -0.850098
    HacR_alignROLL :
    HacR_alignPITCH :
    HacR_alignHPT :
    HacL_HPE1313A:0_Ch58 : -0.212402
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : 0.103027
    HacL_alignROLL : 0.28561
    HacL_alignPITCH : 0.102427
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.614795
    Left Arm Arm Collimator : 0.617041
    Laser attenuation Hall A :
    Laser power Hall A :
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 0
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.122375
    Waterfall Tachometer : 0.767224
    Waterfall Encoder : 1.15445