User name a-onl
Log entry time 16:52:29 on October 24, 2001
Entry number 74949
keyword=Start_Run_1200,Run_type=cosmics,beam_energy=,beam_raster=off,comment_text=cosmics,daq_mode=both HRS daq,leftarm_p=,leftarm_theta=,rightarm_p=,rightarm_theta=,target_name=,target_type=Empty
Beginning-of-run EPICS data for Run Number 1200 at Wed Oct 24 16:52:24 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=9999
Right Arm Q1 power supply current : 796.95
Right Arm Q1 momentum : 1.05987
Right Arm Q1 gauss meter : 0.020057
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 456.232
Right Arm Q2 momentum : 1.0601
Right Arm Q2 gauss meter : -0.2405
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 364.626
Right Arm D1 momentum : 1.06
Right Arm D1 NMR : 0.393353
Right Arm Q3 power supply current : 421.811
Right Arm Q3 momentum : 1.06007
Right Arm Q3 gauss meter : -0.18932
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3084.86
Left Arm Q1 momentum : 4.10041
Left Arm Q1 gauss meter : -0.26059
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1765.42
Left Arm Q2 momentum : 4.09991
Left Arm Q2 gauss meter : 0.9289
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1556.16
Left Arm D1 momentum : 4.1
Left Arm D1 NMR : 1.51901
Left Arm Q3 power supply current : 1632.5
Left Arm Q3 momentum : 4.10054
Left Arm Q3 gauss meter : -0.8164
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0660438
Current on Unser monitor : 5.56823
Current on Upstream bcm : 0.073638
Current on Downstream bcm : 0.0584496
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 4622.17
Beam energy : 4631.65
MBSY1c magnet current (amp) : 0.0377197
Arc1 dp/p : 0
Arc2 dp/p : 0
Waterfall Step Motor Position : -590016
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.129848
Waterfall Tachometer : 0.767224
Waterfall Encoder : 1.10534
Right Arm Arm Collimator : 0.614844
Left Arm Arm Collimator : 0.617041
HacR_HPE1313A:0_Ch58 : -0.505371
HacR_HPE1313A:0_Ch55 : 23.3398
HacR_HPE1313A:0_Ch54 : -0.831543
HacR_alignROLL : -0.350493
HacR_alignPITCH : -0.0485753
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.206543
HacL_HPE1313A:0_Ch55 : 25
HacL_HPE1313A:0_Ch54 : 0.0981445
HacL_alignROLL : 0.283256
HacL_alignPITCH : 0.109791
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 56
Right Arm Angle Vernier : 3.5
Right Arm Scattering Angle : 56.2172
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4998
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1