    Log entry time 08:30:07 on October 26, 2001

    Entry number 75063

    keyword=End_of_Run_1232
    ****************************
     Run Number: 1232
     End of Run Comment:
    Run_type=other,beam_energy=4627,beam_raster=off,comment_text=current scan of target.  TACH=1200, beam current 40 uA  All ps="normal",daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Waterfall
     ps1=220,ps2=12,ps3=1000,ps4=100,ps5=1
    
    PRESCALE FACTORS:ps1=220   ps2=12   ps3=1000   ps4=100   ps5=1   ps8=65535   
    
    EVENTS[0]: 1010289      [+]: 491958       [-]: 499662       
    TIME  [0]: 15.426 mins  [+]: 7.572 mins  [-]: 7.572 mins  
    LIVE  [0]: 927.31%      [+]: 927.35%      [-]: 927.10%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:78.1/17184.9 Hz   T2[0] [PRES/REAL]:39.6/475.0 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:77.5/17055.2 Hz   T2[+] [PRES/REAL]:39.2/470.7 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:78.7/17314.8 Hz   T2[-] [PRES/REAL]:39.9/478.9 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:  72299/15905972  T2[0] [PRES/REAL]:  36635/439631   T8[0] [PRES/REAL]:     14/947795   
    T1[+] [PRES/REAL]:  35222/7748890  T2[+] [PRES/REAL]:  17821/213862   T8[+] [PRES/REAL]:      7/465246   
    T1[-] [PRES/REAL]:  35756/7866375  T2[-] [PRES/REAL]:  18132/217591   T8[-] [PRES/REAL]:      7/465218   
    
    AVERAGE CURRENT
    BCM x1 : 31.0071uA  BCM x3 : 31.1129uA  BCM x10: 31.1459uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -6645 ppm     BCM u3 :    -6467 ppm     BCM u10:    -6504 ppm     
    BCM d1 :    -6653 ppm     BCM d3 :    -6349 ppm     BCM d10:    -6466 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02837        BCM u3 [0]:0.02853        BCM u10[0]:0.02858        
    BCM u1 [+]:0.01383        BCM u3 [+]:0.01391        BCM u10[+]:0.01393        
    BCM u1 [-]:0.01402        BCM u3 [-]:0.01409        BCM u10[-]:0.01412        
    
    BCM d1 [0]:0.02903        BCM d3 [0]:0.02907        BCM d10[0]:0.02908        
    BCM d1 [+]:0.01415        BCM d3 [+]:0.01418        BCM d10[+]:0.01418        
    BCM d1 [-]:0.01434        BCM d3 [-]:0.01436        BCM d10[-]:0.01437        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1232 at Fri Oct 26 08:29:58 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.92
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.733
    Right Arm Q2 momentum : 1.06589
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.752
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.395581
    Right Arm Q3 power supply current : 424.258
    Right Arm Q3 momentum : 1.06622
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.74
    Left Arm Q1 momentum : 4.12018
    Left Arm Q1 gauss meter : -0.26179
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.14
    Left Arm Q2 momentum : 4.12015
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.85
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.34
    Left Arm Q3 momentum : 4.12023
    Left Arm Q3 gauss meter : -0.8203
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 40.5384
    Current on Unser monitor : 46.8195
    Current on Upstream bcm : 40.3146
    Current on Downstream bcm : 40.7623
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 40.5417
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3477.77
    Delta(E)/E width (MV_AI_DXWID) : 10.8515
    IPM1C12.XPOS : -0.00583312
    IPM1H04A.XPOS : 0.0571579
    IPM1H04A.YPOS : -0.0443171
    IPM1H04B.XPOS : 0.10886
    IPM1H04B.YPOS : -0.00820268
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.02715
    Waterfall Tachometer : 1206.14
    Waterfall Encoder : 1.80817
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868604
    HacR_HPE1313A:0_Ch58 : -0.50293
    HacR_HPE1313A:0_Ch55 : 23.7305
    HacR_HPE1313A:0_Ch54 : -0.830078
    HacR_alignROLL : -0.348116
    HacR_alignPITCH : -0.0512912
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.20459
    HacL_HPE1313A:0_Ch55 : 25.3906
    HacL_HPE1313A:0_Ch54 : 0.0917969
    HacL_alignROLL : 0.27792
    HacL_alignPITCH : 0.111325
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.868604
    OTR x-position : 1.80267
    OTR y-position : 0.353489
    OTR x-width : 0.128058
    OTR y-width : 0.126181
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.02715
    Waterfall Tachometer : 1210.01
    Waterfall Encoder : 1.80983