• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:28:34 on October 26, 2001

    Entry number 75079

    keyword=End_of_Run_1238
    ****************************
     Run Number: 1238
     End of Run Comment:
    Run_type=cosmics,beam_energy=4627,beam_raster=off,comment_text=cosmics  TACH=1200, beam current 0 uA all ps=1,daq_mode=both HRS daq,leftarm_p=4.12,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps8=65535   
    
    EVENTS[0]: 356121       [+]: 174763       [-]: 174819       
    TIME  [0]: 131.638 mins  [+]: 64.599 mins  [-]: 64.601 mins  
    LIVE  [0]: 182.39%      [+]: 182.53%      [-]: 182.20%      
    
    TRIGGER RATES:
    T1[0] [PRES/REAL]:10.5/10.5 Hz   T2[0] [PRES/REAL]:14.2/14.2 Hz   T8[0] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[+] [PRES/REAL]:10.4/10.4 Hz   T2[+] [PRES/REAL]:14.2/14.2 Hz   T8[+] [PRES/REAL]: 0.0/1024.0 Hz   
    T1[-] [PRES/REAL]:10.5/10.5 Hz   T2[-] [PRES/REAL]:14.2/14.2 Hz   T8[-] [PRES/REAL]: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:
    T1[0] [PRES/REAL]:  82769/82769    T2[0] [PRES/REAL]: 112358/112358   T8[0] [PRES/REAL]:    123/8087866  
    T1[+] [PRES/REAL]:  40469/40469    T2[+] [PRES/REAL]:  55215/55215    T8[+] [PRES/REAL]:     60/3968985  
    T1[-] [PRES/REAL]:  40771/40771    T2[-] [PRES/REAL]:  55118/55118    T8[-] [PRES/REAL]:     60/3969108  
    
    AVERAGE CURRENT
    BCM x1 : 0.0126 uA  BCM x3 : 0.0331 uA  BCM x10: 0.0469 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 : 1.01E+04 ppm     BCM u3 :     5751 ppm     BCM u10:    415.7 ppm     
    BCM d1 :4.492E+04 ppm     BCM d3 :     1260 ppm     BCM d10:    332.8 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0001508      BCM u3 [0]:9.717E-05      BCM u10[0]:0.0003056      
    BCM u1 [+]:7.36E-05       BCM u3 [+]:4.848E-05      BCM u10[+]:0.0001505      
    BCM u1 [-]:7.213E-05      BCM u3 [-]:4.793E-05      BCM u10[-]:0.0001504      
    
    BCM d1 [0]:4.802E-05      BCM d3 [0]:0.0004253      BCM d10[0]:0.000436       
    BCM d1 [+]:2.321E-05      BCM d3 [+]:0.0002093      BCM d10[+]:0.0002143      
    BCM d1 [-]:2.121E-05      BCM d3 [-]:0.0002088      BCM d10[-]:0.0002142      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1238 at Fri Oct 26 17:28:25 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.11999
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.92
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.57
    Right Arm Q1 momentum : 1.06601
    Right Arm Q1 gauss meter :
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.842
    Right Arm Q2 momentum : 1.06616
    Right Arm Q2 gauss meter :
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.753
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.395581
    Right Arm Q3 power supply current : 424.171
    Right Arm Q3 momentum : 1.066
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3099.74
    Left Arm Q1 momentum : 4.12018
    Left Arm Q1 gauss meter : -0.26177
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.06
    Left Arm Q2 momentum : 4.11997
    Left Arm Q2 gauss meter : 0.9334
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1567.86
    Left Arm D1 momentum : 4.11999
    Left Arm D1 NMR : 1.52643
    Left Arm Q3 power supply current : 1640.14
    Left Arm Q3 momentum : 4.11972
    Left Arm Q3 gauss meter : -0.8202
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 0.0816215
    Current on Unser monitor : 5.29674
    Current on Upstream bcm : 0.073655
    Current on Downstream bcm : 0.0895599
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.92
    Tiefenbach Hall C energy : 3477.77
    Delta(E)/E width (MV_AI_DXWID) : 0.400572
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.06265
    Waterfall Tachometer : 1042.99
    Waterfall Encoder : 1.80807
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.502441
    HacR_HPE1313A:0_Ch55 : 23.7793
    HacR_HPE1313A:0_Ch54 : -0.828613
    HacR_alignROLL : -0.346579
    HacR_alignPITCH : -0.0522567
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.20459
    HacL_HPE1313A:0_Ch55 : 25.5371
    HacL_HPE1313A:0_Ch54 : 0.090332
    HacL_alignROLL : 0.276682
    HacL_alignPITCH : 0.112346
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865283
    Left Arm Arm Collimator : 0.868604
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3508.5
    Waterfall Flow Meter : 4.00473
    Waterfall Tachometer : 1211.94
    Waterfall Encoder : 1.80915