Log entry time 05:25:48 on October 27, 2001
Entry number 75154
keyword=Start_Run_1267,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=L-arm white spectra.,daq_mode=both HRS daq,leftarm_p=4.300,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Carbon (thick)
Beginning-of-run EPICS data for Run Number 1267 at Sat Oct 27 05:25:41 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=220,ps2=7,ps3=40,ps4=52,ps5=1,ps8=65535
Right Arm Q1 power supply current : 801.5
Right Arm Q1 momentum : 1.06592
Right Arm Q1 gauss meter : 0.020204
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.633
Right Arm Q2 momentum : 1.06568
Right Arm Q2 gauss meter : -0.2418
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.377
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.395579
Right Arm Q3 power supply current : 424.226
Right Arm Q3 momentum : 1.06614
Right Arm Q3 gauss meter : -0.19045
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3235.05
Left Arm Q1 momentum : 4.30003
Left Arm Q1 gauss meter : -0.27312
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1851.6
Left Arm Q2 momentum : 4.30004
Left Arm Q2 gauss meter : 0.9741
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1677.07
Left Arm D1 momentum : 4.30001
Left Arm D1 NMR : 1.59323
Left Arm Q3 power supply current : 1711.84
Left Arm Q3 momentum : 4.29983
Left Arm Q3 gauss meter : -0.8562
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.9919
Current on Unser monitor : 45.4818
Current on Upstream bcm : 39.7282
Current on Downstream bcm : 40.2557
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 39.8292
Tiefenbach Hall A energy : 4617.93
Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
Arc1 dp/p : 0.000110014
Arc2 dp/p : -0.000805896
Waterfall Step Motor Position : 349952
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.0999548
Waterfall Tachometer : 0.0421149
Waterfall Encoder : 1.18356
Right Arm Arm Collimator : 0.865186
Left Arm Arm Collimator : 0.868604
HacR_HPE1313A:0_Ch58 : -0.501953
HacR_HPE1313A:0_Ch55 : 23.7793
HacR_HPE1313A:0_Ch54 : -0.830078
HacR_alignROLL : -0.347014
HacR_alignPITCH : -0.0527731
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.203613
HacL_HPE1313A:0_Ch55 : 25.5371
HacL_HPE1313A:0_Ch54 : 0.0898438
HacL_alignROLL : 0.276217
HacL_alignPITCH : 0.11322
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 56
Right Arm Angle Vernier : 3.5
Right Arm Scattering Angle : 56.2172
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4999
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1