User name a-onl
Log entry time 05:43:26 on October 27, 2001
Entry number 75156
keyword=Start_Run_1268,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=L-arm white spectra. all ps factors 1,daq_mode=both HRS daq,leftarm_p=4.300,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Carbon (thick)
Beginning-of-run EPICS data for Run Number 1268 at Sat Oct 27 05:43:21 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=65535
Right Arm Q1 power supply current : 801.5
Right Arm Q1 momentum : 1.06592
Right Arm Q1 gauss meter : 0.020207
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.789
Right Arm Q2 momentum : 1.06604
Right Arm Q2 gauss meter : -0.2418
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.377
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.395579
Right Arm Q3 power supply current : 424.038
Right Arm Q3 momentum : 1.06567
Right Arm Q3 gauss meter : -0.19037
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3234.95
Left Arm Q1 momentum : 4.29989
Left Arm Q1 gauss meter : -0.27315
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1851.41
Left Arm Q2 momentum : 4.29961
Left Arm Q2 gauss meter : 0.974
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1677.06
Left Arm D1 momentum : 4.30001
Left Arm D1 NMR : 1.59323
Left Arm Q3 power supply current : 1711.9
Left Arm Q3 momentum : 4.29997
Left Arm Q3 gauss meter : -0.8563
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 0.0829963
Current on Unser monitor : 5.94977
Current on Upstream bcm : 0.0737602
Current on Downstream bcm : 0.0922324
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 4617.92
Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
Arc1 dp/p : 8.06884e-05
Arc2 dp/p : -0.000812487
Waterfall Step Motor Position : 349952
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.111165
Waterfall Tachometer : 2.21744
Waterfall Encoder : 1.18287
Right Arm Arm Collimator : 0.865234
Left Arm Arm Collimator : 0.868604
HacR_HPE1313A:0_Ch58 : -0.501465
HacR_HPE1313A:0_Ch55 : 23.8281
HacR_HPE1313A:0_Ch54 : -0.82959
HacR_alignROLL : -0.347565
HacR_alignPITCH : -0.0527058
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.204102
HacL_HPE1313A:0_Ch55 : 25.4883
HacL_HPE1313A:0_Ch54 : 0.0908203
HacL_alignROLL : 0.275594
HacL_alignPITCH : 0.113073
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 56
Right Arm Angle Vernier : 3.5
Right Arm Scattering Angle : 56.2172
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4999
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1