    User name a-onl

    Log entry time 06:22:21 on October 27, 2001

    Entry number 75160

    keyword=Start_Run_1270,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=L-arm white spectra.,daq_mode=both HRS daq,leftarm_p=4.245,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Carbon (thick)
    Beginning-of-run EPICS data for Run Number 1270 at Sat Oct 27 06:22:13 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ;
    ps1=220,ps2=7,ps3=40,ps4=52,ps5=1,ps8=65535
    Right Arm Q1 power supply current : 801.43
    Right Arm Q1 momentum : 1.06582
    Right Arm Q1 gauss meter : 0.020221
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.728
    Right Arm Q2 momentum : 1.0659
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.385
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.255
    Right Arm Q3 momentum : 1.06611
    Right Arm Q3 gauss meter : -0.19038
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3193.72
    Left Arm Q1 momentum : 4.24509
    Left Arm Q1 gauss meter : -0.26969
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1827.85
    Left Arm Q2 momentum : 4.24489
    Left Arm Q2 gauss meter : 0.9617
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1642.68
    Left Arm D1 momentum : 4.24501
    Left Arm D1 NMR : 1.57282
    Left Arm Q3 power supply current : 1689.95
    Left Arm Q3 momentum : 4.24484
    Left Arm Q3 gauss meter : -0.8454
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 40.3343
    Current on Unser monitor : 46.0078
    Current on Upstream bcm : 40.1148
    Current on Downstream bcm : 40.5538
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 40.1839
    Tiefenbach Hall A energy : 4617.95
    Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    Arc1 dp/p : 7.30629e-05
    Arc2 dp/p : -0.000808346
    Waterfall Step Motor Position : 349952
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.114901
    Waterfall Tachometer : -1.64981
    Waterfall Encoder : 1.18297
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.868555
    HacR_HPE1313A:0_Ch58 : -0.500977
    HacR_HPE1313A:0_Ch55 : 23.877
    HacR_HPE1313A:0_Ch54 : -0.830078
    HacR_alignROLL : -0.347014
    HacR_alignPITCH : -0.0527731
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.204102
    HacL_HPE1313A:0_Ch55 : 25.4883
    HacL_HPE1313A:0_Ch54 : 0.0908203
    HacL_alignROLL : 0.277068
    HacL_alignPITCH : 0.113147
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 56
    Right Arm Angle Vernier : 3.5
    Right Arm Scattering Angle : 56.2172
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4999
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1