User name a-onl
Log entry time 06:37:12 on October 27, 2001
Entry number 75162
keyword=Start_Run_1271,Run_type=other,beam_energy=4.627,beam_raster=off,comment_text=L-arm white spectra. all ps factors 1,daq_mode=both HRS daq,leftarm_p=4.245,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=,target_type=Carbon (thick)
Beginning-of-run EPICS data for Run Number 1271 at Sat Oct 27 06:36:55 EDT 2001
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 to measure efficiency
;
ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps8=65535
Right Arm Q1 power supply current : 801.43
Right Arm Q1 momentum : 1.06582
Right Arm Q1 gauss meter : 0.020214
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 458.579
Right Arm Q2 momentum : 1.06555
Right Arm Q2 gauss meter : -0.2418
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 366.376
Right Arm D1 momentum : 1.066
Right Arm D1 NMR : 0.395579
Right Arm Q3 power supply current : 424.22
Right Arm Q3 momentum : 1.06612
Right Arm Q3 gauss meter : -0.19042
Right Arm Q3 power supply polarity : enabled
Left Arm Q1 power supply current : 3193.72
Left Arm Q1 momentum : 4.24509
Left Arm Q1 gauss meter : -0.2697
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1827.85
Left Arm Q2 momentum : 4.2449
Left Arm Q2 gauss meter : 0.9618
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1642.68
Left Arm D1 momentum : 4.24501
Left Arm D1 NMR : 1.57282
Left Arm Q3 power supply current : 1690
Left Arm Q3 momentum : 4.24498
Left Arm Q3 gauss meter : -0.8453
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 39.877
Current on Unser monitor : 45.1029
Current on Upstream bcm : 39.6575
Current on Downstream bcm : 40.0965
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.1
Current on IBC0L02 (source) : 39.8063
Tiefenbach Hall A energy : 4617.91
Beam energy : 4627.36
MBSY1c magnet current (amp) : 193.03
Arc1 dp/p : 7.50755e-05
Arc2 dp/p : -0.000825182
Waterfall Step Motor Position : 349952
Waterfall Pump Speed : 2048
Waterfall Flow Meter : -0.122375
Waterfall Tachometer : 3.18425
Waterfall Encoder : 1.18278
Right Arm Arm Collimator : 0.865186
Left Arm Arm Collimator : 0.868604
HacR_HPE1313A:0_Ch58 : -0.501953
HacR_HPE1313A:0_Ch55 : 23.8281
HacR_HPE1313A:0_Ch54 : -0.82959
HacR_alignROLL : -0.347507
HacR_alignPITCH : -0.0523239
HacR_alignHPT : -0
HacL_HPE1313A:0_Ch58 : -0.203613
HacL_HPE1313A:0_Ch55 : 25.5371
HacL_HPE1313A:0_Ch54 : 0.0898438
HacL_alignROLL : 0.276217
HacL_alignPITCH : 0.11322
HacL_alignHPT : -0
Right Arm Angle Floor Angle : 56
Right Arm Angle Vernier : 3.5
Right Arm Scattering Angle : 56.2172
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 12.4999
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1