    User name a-onl

    Log entry time 17:22:06 on October 27, 2001

    Entry number 75209

    keyword=End_of_Run_1290
    ****************************
     Run Number: 1290
     End of Run Comment:
    Run_type=cosmics,beam_energy=4.627,beam_raster=off,comment_text=L-arm sieve slit run for RCS.  ps=1/65535/65535/65535/65535,daq_mode=both HRS daq,leftarm_p=4.3000,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=56.217,target_name=c12,target_type=Carbon (thick)
     
    
    PRESCALE FACTORS:ps1=1   ps2=65535   ps3=65535   ps4=65535   ps5=65535   ps8=65535   
    
    EVENTS[0]: 491769       [+]: 240187       [-]: 242354       
    TIME  [0]: 3.743 mins  [+]: 1.837 mins  [-]: 1.836 mins  
    LIVE  [0]:  73.16%      [+]:  73.29%      [-]:  73.03%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :2993.1/2993.1 Hz   T2[0] : 0.0/97.9 Hz   T3[0] : 0.0/140.3 Hz   T4[0] : 0.0/80.1 Hz   T5[0] : 0.0/3.6  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :2973.8/2973.8 Hz   T2[+] : 0.0/98.1 Hz   T3[+] : 0.0/137.2 Hz   T4[+] : 0.0/80.1 Hz   T5[+] : 0.0/3.5  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :3012.1/3012.1 Hz   T2[-] : 0.0/97.8 Hz   T3[-] : 0.0/143.3 Hz   T4[-] : 0.0/80.3 Hz   T5[-] : 0.0/3.7  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 672142/672142   T2[0] :      0/21987    T3[0] :      0/31500    T4[0] :      0/17989    T5[0] :      0/815      T8[0] :      3/229954   
    T1[+] : 327726/327726   T2[+] :      0/10811    T3[+] :      0/15125    T4[+] :      0/8823     T5[+] :      0/387      T8[+] :      1/112848   
    T1[-] : 331833/331833   T2[-] :      0/10777    T3[-] :      0/15785    T4[-] :      0/8848     T5[-] :      0/413      T8[-] :      1/112809   
    
    AVERAGE CURRENT
    BCM x1 : 10.2022uA  BCM x3 : 10.2564uA  BCM x10: 10.2812uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -5592 ppm     BCM u3 :    -5456 ppm     BCM u10:    -5484 ppm     
    BCM d1 :    -5590 ppm     BCM d3 :    -5348 ppm     BCM d10:    -5451 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002268       BCM u3 [0]:0.002279       BCM u10[0]:0.002287       
    BCM u1 [+]:0.001107       BCM u3 [+]:0.001112       BCM u10[+]:0.001116       
    BCM u1 [-]:0.001119       BCM u3 [-]:0.001124       BCM u10[-]:0.001128       
    
    BCM d1 [0]:0.002314       BCM d3 [0]:0.002328       BCM d10[0]:0.00233        
    BCM d1 [+]:0.001129       BCM d3 [+]:0.001136       BCM d10[+]:0.001137       
    BCM d1 [-]:0.001142       BCM d3 [-]:0.001148       BCM d10[-]:0.001149       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1290 at Sat Oct 27 17:21:24 EDT 2001
    Right Arm D1 momentum : 1.066
    Right Arm arm angle : 56.2172
    Left Arm D1 momentum : 4.3
    Left Arm arm angle : 12.4999
    Tiefenbach Hall A energy : 4617.88
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.43
    Right Arm Q1 momentum :
    Right Arm Q1 gauss meter : 0.020222
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.649
    Right Arm Q2 momentum : 1.06571
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.384
    Right Arm D1 momentum : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.244
    Right Arm Q3 momentum : 1.06618
    Right Arm Q3 gauss meter : -0.19043
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3235.12
    Left Arm Q1 momentum :
    Left Arm Q1 gauss meter : -0.27318
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1851.62
    Left Arm Q2 momentum : 4.3001
    Left Arm Q2 gauss meter : 0.9741
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1677.09
    Left Arm D1 momentum : 4.3
    Left Arm D1 NMR : 1.59322
    Left Arm Q3 power supply current : 1711.96
    Left Arm Q3 momentum : 4.30013
    Left Arm Q3 gauss meter : -0.8563
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 10.2104
    Current on Unser monitor : 15.8653
    Current on Upstream bcm : 10.1136
    Current on Downstream bcm : 10.284
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 10.2448
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.88
    Tiefenbach Hall C energy : 3478.88
    Delta(E)/E width (MV_AI_DXWID) : 4.79623
    IPM1C12.XPOS : 0.00554803
    IPM1H04A.XPOS : -0.0337649
    IPM1H04A.YPOS : -0.0449152
    IPM1H04B.XPOS : 0.0791544
    IPM1H04B.YPOS : -0.0158167
    Waterfall Step Motor Position : 349952
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.109296
    Waterfall Tachometer : -0.441291
    Waterfall Encoder : 1.18356
    Right Arm Arm Collimator : 0.865186
    Left Arm Arm Collimator : 0.365967
    HacR_HPE1313A:0_Ch58 : -0.500977
    HacR_HPE1313A:0_Ch55 : 23.8281
    HacR_HPE1313A:0_Ch54 : -0.828613
    HacR_alignROLL : -0.346463
    HacR_alignPITCH : -0.0528403
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202637
    HacL_HPE1313A:0_Ch55 : 25.5371
    HacL_HPE1313A:0_Ch54 : 0.090332
    HacL_alignROLL : 0.276682
    HacL_alignPITCH : 0.114094
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.865234
    Left Arm Arm Collimator : 0.366064
    OTR x-position : -6.7914
    OTR y-position : 3.57362
    OTR x-width : 0
    OTR y-width : -0
    OTR data valid flag : No
    Waterfall Step Motor Position : 349952
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.103691
    Waterfall Tachometer : 0.767224
    Waterfall Encoder : 1.18297