    User name a-onl

    Log entry time 23:59:16 on October 27, 2001

    Entry number 75247

    keyword=Start_Run_1305,Run_type=production,beam_energy=4.627,beam_raster=on,comment_text=collimator open on both arms. Beo Target run.,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=59.97,target_name=BeO,target_type=BeO
    Beginning-of-run EPICS data for Run Number 1305 at Sat Oct 27 23:59:11 EDT 2001
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string.
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ;
    ps1=35,ps2=3,ps3=250,ps4=25,ps5=1,ps8=65535
    Right Arm Q1 power supply current : 801.57
    Right Arm Q1 momentum : 1.06601
    Right Arm Q1 gauss meter : 0.020212
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 459.022
    Right Arm Q2 momentum : 1.06658
    Right Arm Q2 gauss meter : -0.2419
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.377
    Right Arm D1 momentum : 1.066
    Right Arm D1 NMR : 0.39558
    Right Arm Q3 power supply current : 424.274
    Right Arm Q3 momentum : 1.06624
    Right Arm Q3 gauss meter : -0.19041
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.51
    Left Arm Q1 momentum : 4.1212
    Left Arm Q1 gauss meter : -0.26192
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.35
    Left Arm Q2 momentum : 4.12065
    Left Arm Q2 gauss meter : 0.9339
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.04
    Left Arm D1 momentum : 4.121
    Left Arm D1 NMR : 1.5268
    Left Arm Q3 power supply current : 1640.62
    Left Arm Q3 momentum : 4.12093
    Left Arm Q3 gauss meter : -0.8207
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 29.268
    Current on Unser monitor : 35.517
    Current on Upstream bcm : 29.035
    Current on Downstream bcm : 29.5011
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 29.3057
    Tiefenbach Hall A energy : 4617.92
    Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    Arc1 dp/p : 9.18885e-05
    Arc2 dp/p : -0.000850259
    Waterfall Step Motor Position : 1.33478e+06
    Waterfall Pump Speed : 2048
    Waterfall Flow Meter : -0.124243
    Waterfall Tachometer : 8.50172
    Waterfall Encoder : 1.26727
    Right Arm Arm Collimator : 0.865381
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.478027
    HacR_HPE1313A:0_Ch55 : 23.8281
    HacR_HPE1313A:0_Ch54 : -0.78418
    HacR_alignROLL : -0.301633
    HacR_alignPITCH : -0.0743323
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202637
    HacL_HPE1313A:0_Ch55 : 25.5371
    HacL_HPE1313A:0_Ch54 : 0.090332
    HacL_alignROLL : 0.277613
    HacL_alignPITCH : 0.114968
    HacL_alignHPT : -0
    Right Arm Angle Floor Angle : 60
    Right Arm Angle Vernier : -39.4
    Right Arm Scattering Angle : 59.9699
    Left Arm Angle Floor Angle : 12.5
    Left Arm Angle Vernier : 31
    Left Arm Scattering Angle : 12.4999
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1