• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 23:44:46 on November 1, 2001

    Entry number 75593

    keyword=End_of_Run_1432
    ****************************
     Run Number: 1432
     End of Run Comment:
    Run_type=production,beam_energy=4.627,beam_raster=off,comment_text=CW 100uA,daq_mode=both HRS daq,leftarm_p=4.121,leftarm_theta=12.500,rightarm_p=1.066,rightarm_theta=74.82,target_name=H2O,target_type=Waterfall
     
    
    PRESCALE FACTORS:ps1=114   ps2=16   ps3=2400   ps4=240   ps5=1   ps8=65535   
    
    EVENTS[0]: 1499276      [+]: 737131       [-]: 733584       
    TIME  [0]: 52.486 mins  [+]: 25.748 mins  [-]: 25.749 mins  
    LIVE  [0]:  95.03%      [+]:  94.97%      [-]:  95.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :77.9/8882.2 Hz   T2[0] :40.3/645.3 Hz   T3[0] :91.6/219950.2 Hz   T4[0] :52.2/12522.7 Hz   T5[0] :238.9/238.9 Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :78.1/8901.3 Hz   T2[+] :40.4/646.7 Hz   T3[+] :91.8/220350.8 Hz   T4[+] :52.3/12546.4 Hz   T5[+] :239.8/239.8 Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :77.7/8863.3 Hz   T2[-] :40.2/643.9 Hz   T3[-] :91.5/219546.5 Hz   T4[-] :52.1/12498.5 Hz   T5[-] :238.0/238.0 Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 245365/27971661  T2[0] : 127016/2032271  T3[0] : 288610/692664622  T4[0] : 164318/39436454  T5[0] : 752303/752303   T8[0] :     49/3224769  
    T1[+] : 120627/13751526  T2[+] :  62443/999098   T3[+] : 141840/340416317  T4[+] :  80761/19382699  T5[+] : 370471/370471   T8[+] :     24/1581961  
    T1[-] : 120118/13693504  T2[-] :  62179/994867   T3[-] : 141329/339191751  T4[-] :  80457/19309788  T5[-] : 367771/367771   T8[-] :     24/1582045  
    
    AVERAGE CURRENT
    BCM x1 : 90.5682uA  BCM x3 : 90.7907uA  BCM x10: -34.1876uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1705 ppm     BCM u3 :     1660 ppm     BCM u10:    698.6 ppm     
    BCM d1 :     1705 ppm     BCM d3 :     1627 ppm     BCM d10:    823.6 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.2819         BCM u3 [0]:0.2834         BCM u10[0]:-0.1153        
    BCM u1 [+]:0.1385         BCM u3 [+]:0.1392         BCM u10[+]:0.1119         
    BCM u1 [-]:0.1381         BCM u3 [-]:0.1388         BCM u10[-]:0.1117         
    
    BCM d1 [0]:0.2885         BCM d3 [0]:0.2885         BCM d10[0]:-0.1001        
    BCM d1 [+]:0.1418         BCM d3 [+]:0.1418         BCM d10[+]:0.1165         
    BCM d1 [-]:0.1413         BCM d3 [-]:0.1413         BCM d10[-]:0.1164         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1432 at Thu Nov 1 23:44:40 EST 2001
    Right Arm D1 momentum : 1.06608
    Right Arm arm angle : 74.8198
    Left Arm D1 momentum : 4.12098
    Left Arm arm angle : 12.4998
    Tiefenbach Hall A energy : 4617.96
    Right Arm arm mispointing (HPT) : -0
    Left Arm arm mispointing (HPT) : -0
    Right Arm Q1 power supply current : 801.675
    Right Arm Q1 momentum : 1.06615
    Right Arm Q1 gauss meter : 0.020169
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 458.715
    Right Arm Q2 momentum : 1.06587
    Right Arm Q2 gauss meter : -0.2418
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 366.869
    Right Arm D1 momentum : 1.06608
    Right Arm D1 NMR : 0.395611
    Right Arm Q3 power supply current : 424.313
    Right Arm Q3 momentum : 1.06636
    Right Arm Q3 gauss meter : -0.19036
    Right Arm Q3 power supply polarity : enabled
    Left Arm Q1 power supply current : 3100.37
    Left Arm Q1 momentum : 4.12102
    Left Arm Q1 gauss meter : -0.26176
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1774.34
    Left Arm Q2 momentum : 4.12063
    Left Arm Q2 gauss meter : 0.9336
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1568.43
    Left Arm D1 momentum : 4.12098
    Left Arm D1 NMR : 1.52679
    Left Arm Q3 power supply current : 1640.75
    Left Arm Q3 momentum : 4.12125
    Left Arm Q3 gauss meter : -0.8206
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 100.386
    Current on Unser monitor : 106.23
    Current on Upstream bcm : 99.7162
    Current on Downstream bcm : 101.057
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.1
    Current on IBC0L02 (source) : 99.6086
    MBSY1c Hall A Beam energy : 4627.36
    MBSY1c magnet current (amp) : 193.03
    MBSY1c Bdl : 1.15476e+06
    MBSY3c Hall C Beam energy : 3489.29
    Tiefenbach Hall A energy : 4617.96
    Tiefenbach Hall C energy : 3479.73
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.0146692
    IPM1H04A.XPOS : -0.228354
    IPM1H04A.YPOS : -0.0449423
    IPM1H04B.XPOS : -0.0477712
    IPM1H04B.YPOS : -0.0399797
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.35411
    Waterfall Tachometer : 1221.85
    Waterfall Encoder : 1.80219
    Right Arm Arm Collimator : 0.86543
    Left Arm Arm Collimator : 0.868701
    HacR_HPE1313A:0_Ch58 : -0.492188
    HacR_HPE1313A:0_Ch55 : 23.9746
    HacR_HPE1313A:0_Ch54 : -0.73877
    HacR_alignROLL : -0.254653
    HacR_alignPITCH : -0.061891
    HacR_alignHPT : -0
    HacL_HPE1313A:0_Ch58 : -0.202637
    HacL_HPE1313A:0_Ch55 : 25.7812
    HacL_HPE1313A:0_Ch54 : 0.0952148
    HacL_alignROLL : 0.281729
    HacL_alignPITCH : 0.114461
    HacL_alignHPT : -0
    Right Arm Arm Collimator : 0.86543
    Left Arm Arm Collimator : 0.868701
    OTR x-position : -1.02988
    OTR y-position : -3.43083
    OTR x-width : 0.184107
    OTR y-width : 0.156046
    OTR data valid flag : Yes
    Waterfall Step Motor Position : 7.67501e+06
    Waterfall Pump Speed : 3554.5
    Waterfall Flow Meter : 4.39521
    Waterfall Tachometer : 1267.29
    Waterfall Encoder : 1.80199